文献速递骨肌技术与安全MRPET

3T扩散加权MRI与18F-FDG PET/CT在肌肉骨骼肿瘤中的比较:表观扩散系数与标准化摄取值定量分析

Comparison of 3T diffusion-weighted MRI and 18F-FDG PET/CT in musculoskeletal tumours: quantitative analysis of apparent diffusion coefficients and standardized uptake values.
PubMed 文献 · Br J Radiol · 2019-07-24

回顾性队列纳入57例病理确诊的软组织(32例)和骨(25例)肿瘤患者,治疗前均行3T MR DWI及全身18F-FDG PET/CT,其中14例治疗后复查。肿瘤SUVmax与ADCmin/ADCmus比值、SUVmean与ADCmean/ADCmus比值均呈负相关;治疗后ADC显著升高而SUV显著下降,ADCmin与SUVmax变化百分比显著相关。

要点

  • 肌肉骨骼肿瘤中3T DWI的ADC与18F-FDG PET/CT的SUV呈负相关,可互为补充。
  • SUVmax与ADCmin/ADCmus比值负相关(r=-0.505至-0.495,p≤0.001)。
  • 治疗后ADCmin升高163%、SUVmax降低61%见于11例治疗有效患者。

核心结论

  • 3T MR DWI的ADC与18F-FDG PET/CT的SUV在肌肉骨骼肿瘤中呈负相关。
  • 治疗后ADC显著升高而SUV显著下降(p=0.001),ADCmin与SUVmax变化百分比显著相关。

研究设计与样本

  • 回顾性队列研究,纳入57例病理确诊的肌肉骨骼肿瘤患者(软组织32例、骨25例;男36例、女21例;平均年龄54岁,范围12-90岁)。
  • 治疗前均行3T MR成像(含DWI)及全身18F-FDG PET/CT,其中14例治疗后复查MR及PET/CT。
  • 获取肿瘤ADCmin、ADCmean、正常骨骼肌ADC(ADCmus)、肿瘤SUVmax及SUVmean,以Pearson相关系数评估ADC与SUV相关性,t检验比较治疗前后ADCmin与SUVmax。

诊断标准与关键数值

  • 肿瘤SUVmax与ADCmin/ADCmus比值呈负相关(r=-0.505至-0.495,p≤0.001)。
  • 肿瘤SUVmean与ADCmean/ADCmus比值呈负相关(r=-0.501至-0.493,p=0.001)。
  • 治疗前后ADCmin与SUVmax的变化百分比呈显著相关(r=0.750至0.773,p≤0.005)。
  • 11例治疗有效患者中,ADCmin升高163%,SUVmax降低61%。

临床应用与阅片要点

  • 肌肉骨骼肿瘤阅片时可结合3T DWI的ADC与18F-FDG PET/CT的SUV进行综合评估,二者呈负相关。
  • 治疗后ADC升高伴SUV下降可能提示治疗反应,ADCmin与SUVmax变化百分比具有相关性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To determine whether the apparent diffusion coefficient (ADC) on 3T MR imaging including diffusion-weighted MR imaging (DWI) correlate with the standardized uptake value (SUV) on 18F-FDG PET/CT in musculoskeletal tumours.

METHODS: This retrospective cohort study included 57 patients (36 males, 21 females, mean age 54 years, range 12-90 years) with pathologically confirmed soft tissue (n = 32) and bone (n = 25) tumours who underwent 3T MR imaging including DWI and whole-body 18F-FDG PET/CT before treatment. 14 patients had follow-up MR imaging and 18F-FDG PET/CT after treatment. The minimum (ADCmin) and mean (ADCmean) ADCs of musculoskeletal tumour, ADC of normal skeletal muscle (ADCmus), SUVmax and SUVmean of musculoskeletal tumour were obtained. Correlation between ADCs and SUVs was assessed using Pearson correlation coefficients (r). ADCmin and SUVmax were compared between pretreatment and posttreatment by t-test.

RESULTS: There was inverse correlation between SUVmax and the ratio ADCmin/ADCmus (r = - 0.505 to - 0.495, p ≤ 0.001) and between SUVmean and the ratio ADCmean/ADCmus (r = - 0.501 to - 0.493, p = 0.001). After treatment ADC was significantly increased whereas SUV was significantly decreased (p = 0.001). There was significant correlation in percent change between the initial and follow-up values of ADCmin and SUVmax (r = 0.750 to 0.773, p ≤ 0.005). The ADCmin was increased by 163% and SUVmax was decreased by 61% in 11 patients with treatment response.

CONCLUSION: ADC at 3T MR DWI and SUV at 18F-FDG PET/CT have an inverse correlation in musculoskeletal tumours.

ADVANCES IN KNOWLEDGE: Our study showed that ADC at 3T DWI and SUV at 18F-FDG PET/CT had an inverse correlation in musculoskeletal tumours.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Lee SY, Jee WH, Yoo IR, et al. Comparison of 3T diffusion-weighted MRI and 18F-FDG PET/CT in musculoskeletal tumours: quantitative analysis of apparent diffusion coefficients and standardized uptake values. Br J Radiol. 2019. PMID: 31322913. doi:10.1259/bjr.20181051

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。