文献速递骨肌CTMR

彩色编码虚拟去钙双能CT显示急性膝关节创伤患者骨髓水肿:一项多读者诊断准确性研究

Color-coded virtual non-calcium dual-energy CT for the depiction of bone marrow edema in patients with acute knee trauma: a multireader diagnostic accuracy study.
PubMed 文献 · Eur Radiol · 2019-07-26

回顾性分析57例急性膝关节创伤患者,均在7天内完成第三代双源双能CT和3T MRI,以MRI为参考标准。六名放射科医师盲法评估彩色编码虚拟去钙(VNCa)重建显示骨髓水肿的敏感度94%、特异度95%,股骨和胫骨AUC分别为0.96和0.97;胫骨骨髓水肿鉴别阈值-51 HU时敏感度96%、特异度97%。

要点

  • VNCa重建显示创伤性膝关节骨髓水肿的总体敏感度94%(1108/1182)、特异度95%(2789/2922)。
  • 股骨和胫骨骨髓水肿的AUC分别为0.96和0.97。
  • 胫骨骨髓水肿鉴别阈值-51 HU,敏感度96%(102/106)、特异度97%(229/236)。

核心结论

  • 在定量和定性分析中,双能CT VNCa重建与MRI相比,显示创伤性膝关节骨髓水肿具有极好的诊断准确性。

研究设计与样本

  • 回顾性分析57例急性膝关节创伤患者(平均年龄50岁,范围20-82岁;女30例,男27例),于2017年1月至2018年5月间在7天内完成第三代双源双能CT和3T MRI。
  • 六名放射科医师盲法独立分析常规灰度双能CT系列以检出骨折;8周后评估彩色编码VNCa重建上六个股骨和六个胫骨区域的骨髓水肿。
  • 第七名放射科医师对VNCa重建进行CT值定量分析;两名额外放射科医师盲法共识分析MRI系列以定义参考标准。

关键影像表现/征象

  • MRI显示197处骨髓水肿区域(股骨91/342,胫骨106/342)。
  • VNCa重建与MRI系列的诊断信心、图像噪声和图像质量评分相当。

诊断标准与关键数值

  • VNCa定性分析显示骨髓水肿的总体敏感度94%(1108/1182)、特异度95%(2789/2922)。
  • 股骨骨髓水肿AUC为0.96,胫骨骨髓水肿AUC为0.97。
  • 胫骨骨髓水肿鉴别阈值-51 HU,敏感度96%(102/106)、特异度97%(229/236)。

临床应用与阅片要点

  • VNCa图像可能作为MRI的替代影像学方法。
  • 诊断信心、图像噪声和图像质量在VNCa重建与MRI系列中被评为相当。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the diagnostic accuracy of dual-energy computed tomography (CT) virtual non-calcium (VNCa) reconstructions for the depiction of traumatic knee bone marrow edema.

METHODS: Fifty-seven patients (mean age, 50 years; range, 20-82 years) with acute knee trauma further divided into 30 women and 27 men, who had undergone third-generation dual-source dual-energy CT and 3-T magnetic resonance imaging (MRI) within 7 days between January 2017 and May 2018, were retrospectively analyzed. Six radiologists, blinded to clinical and MRI information, independently analyzed conventional grayscale dual-energy CT series for fractures; after 8 weeks, readers evaluated color-coded VNCa reconstructions for the presence of bone marrow edema in six femoral and six tibial regions. Quantitative analysis of CT numbers on VNCa reconstructions was performed by a seventh radiologist. Two additional radiologists, blinded to clinical and CT information, analyzed MRI series in consensus to define the reference standard. Sensitivity, specificity, and the area under the curve (AUC) were the primary metrics of diagnostic accuracy.

RESULTS: MRI revealed 197 areas with bone marrow edema (91/342 femoral, 106/342 tibial). In the qualitative analysis, VNCa showed high overall sensitivity (1108/1182 [94%]) and specificity (2789/2922 [95%]) for depicting bone marrow edema. The AUC was 0.96 (femur) and 0.97 (tibia). A cutoff value of - 51 Hounsfield units (HU) provided high sensitivity (102/106 [96%]) and specificity (229/236 [97%]) for differentiating tibial bone marrow edema.

CONCLUSIONS: In both quantitative and qualitative analyses, dual-energy CT VNCa reconstructions yielded excellent diagnostic accuracy for depicting traumatic knee bone marrow edema compared with MRI.

KEY POINTS: • Dual-energy CT (DECT) virtual non-calcium (VNCa) reconstructions are highly accurate in depicting bone marrow edema of the femur and tibia. • Diagnostic confidence, image noise, and image quality were rated as equivalent in VNCa reconstructions and MRI (magnetic resonance imaging) series. • VNCa images may serve as an alternative imaging approach to MRI.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Booz C, Nöske J, Lenga L, et al. Color-coded virtual non-calcium dual-energy CT for the depiction of bone marrow edema in patients with acute knee trauma: a multireader diagnostic accuracy study. Eur Radiol. 2019. PMID: 31350586. doi:10.1007/s00330-019-06304-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。