文献速递骨肌MR

压缩感知加速踝关节二维快速自旋回波成像

Accelerating anatomical 2D turbo spin echo imaging of the ankle using compressed sensing.
PubMed 文献 · Eur J Radiol · 2019-06-16

研究纳入20名志愿者(平均年龄30.2±7.3岁,13名男性)在3 T MRI上扫描踝关节,比较仅用SENSE与压缩感知联合SENSE的二维快速自旋回波序列。压缩感知使总采集时间减少20%,图像质量评分一致性高(κ=0.75-0.89),信噪比略高但无统计学差异(P=0.18-0.62),对比噪声比无显著差异(P>0.05)。结论为压缩感知在减少20%采集时间的同时未降低诊断图像质量、信噪比和对比噪声比。

要点

  • 压缩感知联合SENSE使踝关节MRI总采集时间减少20%。
  • 两种技术图像质量评分一致性高(κ=0.75-0.89),信噪比与对比噪声比无显著差异。
  • 该技术可在不降低诊断图像质量的前提下加速踝关节二维快速自旋回波成像。

核心结论

  • 压缩感知使踝关节常规MR成像采集时间减少20%,且未降低诊断图像质量、信噪比和对比噪声比。

研究设计与样本

  • 前瞻性可行性研究,纳入20名志愿者的踝关节,在3 T MRI上采集冠状位和矢状位中间加权脂肪抑制序列、轴位T2加权和冠状位T1加权序列,分别使用仅基于敏感度编码的并行成像(SENSE)及压缩感知联合SENSE两种方式;由两名放射科医生阅片,采用5点Likert量表评分图像质量,并用Wilcoxon符号秩检验和Cohen kappa比较信噪比与对比噪声比。

诊断标准与关键数值

  • 图像质量采用5点Likert量表评分;仅SENSE与压缩感知联合SENSE在评估软骨、软骨下骨和韧带时的评分一致性为κ=0.75-0.89;信噪比在压缩感知联合SENSE序列略高于仅SENSE序列,但无统计学差异(P=0.18-0.62);软骨/液体、软骨下骨/软骨、韧带/液体和韧带/脂肪的对比噪声比在两种序列间无显著差异(P>0.05);两名阅片者间一致性为κ=0.75-0.89。

临床应用与阅片要点

  • 压缩感知联合SENSE可在减少20%采集时间的同时保持与仅SENSE相当的诊断图像质量、信噪比和对比噪声比,可用于踝关节二维快速自旋回波MRI加速采集。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

INTRODUCTION: To assess the feasibility and diagnostic value of compressed sensing for accelerating two-dimensional turbo spin echo imaging of the ankle.

MATERIALS AND METHODS: Ankles of 20 volunteers were scanned (mean age 30.2 ± 7.3 years, 13 men) at 3 T MRI. Coronal and sagittal intermediate-weighted (IM) sequences with fat saturation as well as axial T2- and coronal T1-weighted sequences were acquired using parallel imaging based on sensitivity encoding (SENSE) only as well as with a combination of compressed sensing (CS) and SENSE. Compressed sensing is a technique that acquires less data through k-space random undersampling and enables a reduction in total acquisition time by 20%. All images were reviewed by two radiologists, image quality was graded using a 5-point Likert scale and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of different anatomical structures of the ankle were assessed and compared between sequences with SENSE only and with the combination of CS and SENSE using Wilcoxon signed-rank tests and Cohen's kappa.

RESULTS: There was a substantial to perfect agreement for the rating between the images acquired with SENSE only and with the combination of CS and SENSE when assessing cartilage, subchondral bone and ligaments (κ = 0.75 - 0.89). SNR was slightly higher for the combination of CS and SENSE sequences compared to the sequences acquired with SENSE only, yet this finding was not significant (P = 0.18-0.62). Moreover, CNR of cartilage/fluid, subchondral bone/cartilage, ligaments/fluid and ligaments/fat did not show significant differences between the sequences acquired with SENSE only and the combination of CS and SENSE (P > 0.05). The interreader agreement was substantial to excellent for both techniques (κ=0.75 - 0.89).

CONCLUSIONS: Compressed sensing reduced the acquisition time of conventional MR imaging of the ankle by 20% without decreasing diagnostic image quality, SNR and CNR.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Gersing AS, Bodden J, Neumann J, et al. Accelerating anatomical 2D turbo spin echo imaging of the ankle using compressed sensing. Eur J Radiol. 2019. PMID: 31301872. doi:10.1016/j.ejrad.2019.06.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。