PubMed 文献 · Clin Radiol · 2019-07-24

研究纳入35例膝关节损伤患者,于2018年3月至11月间行双能CT虚拟去钙(VNCa)与MRI检查。彩色编码VNCa图像定性诊断骨髓水肿的敏感度88.4%、特异度98%、准确率95.9%;衰减值ROC曲线AUC为0.910,以-67 HU为阈值时敏感度81.4%、特异度99.3%。结论认为双能CT VNCa可有效评估骨髓水肿。

要点

  • 彩色编码双能CT VNCa图像定性诊断膝关节骨髓水肿敏感度88.4%、特异度98%。
  • VNCa衰减值鉴别水肿区的AUC为0.910,阈值-67 HU时特异度99.3%。
  • 双能CT与MRI测得的水肿面积大小无显著差异。

核心结论

  • 双能CT虚拟去钙(VNCa)技术可有效评估膝关节骨髓水肿。

研究设计与样本

  • 研究纳入35例膝关节损伤患者,于2018年3月至2018年11月间均行双能CT和MRI检查。
  • 由两名独立放射科医生使用彩色编码双能CT VNCa图像评估骨髓水肿并测量衰减值,另一名放射科医生分别在双能CT和MRI轴位图像上测量骨髓水肿最大面积。
  • 衰减值行ROC曲线分析,水肿面积大小行配对t检验分析。

关键影像表现/征象

  • 彩色编码VNCa图像上,有水肿与无水肿的膝关节区域衰减值差异有统计学意义(p<0.001)。

诊断标准与关键数值

  • 彩色编码VNCa图像定性分析诊断骨髓水肿的总体敏感度88.4%、特异度98%、阳性预测值92.7%、阴性预测值96.8%、准确率95.9%。
  • VNCa衰减值鉴别水肿膝关节区域的AUC为0.910。
  • 以-67 HU为截断值时,鉴别水肿膝关节区域的敏感度81.4%、特异度99.3%、准确率90.4%、阳性预测值99.1%、阴性预测值84.2%。

临床应用与阅片要点

  • 双能CT VNCa可用于评估膝关节骨髓水肿,彩色编码图像可定性显示水肿,衰减值可定量辅助鉴别。
  • 双能CT与MRI测得的水肿面积大小无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate bone marrow oedema in knee joints quantitatively and qualitatively using a dual-energy computed tomography (CT) virtual non-calcium (VNCa) technique.

MATERIALS AND METHODS: Thirty-five patients with knee joint injuries underwent both dual-energy CT and magnetic resonance imaging (MRI) between March 2018 and November 2018. The presence of bone marrow oedema was assessed by two independent radiologists with the use of colour-coded dual-energy CT VNCa images and measured attenuation on them. The biggest area of bone marrow oedema on axial images was measured by another radiologist using the dual-energy CT and MRI images, respectively. Attenuation values were subjected to receiver operating characteristic (ROC) curve analysis and oedema area sizes were subjected to paired t-test analysis.

RESULTS: In qualitative analysis, colour-coded VNCa images had an overall sensitivity of 88.4%, specificity of 98%, positive predictive value of 92.7%, negative predictive value of 96.8%, and accuracy of 95.9%. Attenuation values obtained from colour-coded VNCa images were significantly different in knee joint regions with and without oedema (p<0.001). ROC curve analysis revealed an area under the curve (AUC) of 0.910. A cut-off value of -67 HU provided a sensitivity of 81.4%, specificity of 99.3%, accuracy of 90.4%, positive predictive value of 99.1%, and negative predictive value of 84.2% for the differentiation of oedematous knee joint regions. Significant differences in the size of oedema area were not found between them.

CONCLUSION: Dual-energy CT VNCa can be used to evaluate bone marrow oedema effectively.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Wang MY, Zhang XY, Xu L, et al. Detection of bone marrow oedema in knee joints using a dual-energy CT virtual non-calcium technique. Clin Radiol. 2019. PMID: 31351574. doi:10.1016/j.crad.2019.06.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。