甲状腺影像报告和数据系统(TI-RADS)在甲状腺结节分类中的有效性和可重复性:多中心前瞻性研究
该多中心前瞻性研究纳入380例患者共948个甲状腺结节,由三名放射科医生基于ACR TI-RADS独立分类,以细胞学为参考标准。以大于TR3为恶性预测界值时,敏感度98.3%、特异度90.9%、准确率92.1%,观察者间一致性良好(κ=0.636)。结论认为TI-RADS可提高超声预测恶性甲状腺结节的诊断效能,具有高有效性和高可重复性。
要点
- 预测恶性甲状腺结节的最佳截断值为大于TR3。
- 以大于TR3为界值时,TI-RADS的敏感度98.3%、特异度90.9%、准确率92.1%。
- TI-RADS分类的观察者间一致性良好(κ=0.636)。
核心结论
- TI-RADS可提高超声预测恶性甲状腺结节的诊断效能,具有高有效性和高可重复性。
研究设计与样本
- 多中心前瞻性研究,初始纳入557例临床疑似甲状腺结节患者,排除后最终纳入380例患者共948个甲状腺结节。
- 基于美国放射学会(ACR)TI-RADS,三名放射科医生独立分析所有超声检查并为每个甲状腺结节指定TI-RADS分类。
- 最终诊断基于细胞学,作为计算TI-RADS预测恶性甲状腺结节诊断效能的参考标准。
- 采用Fleiss和加权kappa(κ)统计评估形态学特征和TI-RADS评分结果的观察者间一致性。
诊断标准与关键数值
- 预测恶性甲状腺结节的最佳截断值为大于TR3。
- 基于病灶分析,将分类为大于TR3的甲状腺结节视为预测恶性时,TI-RADS的敏感度98.3%、特异度90.9%、准确率92.1%。
- 共评估948个甲状腺结节,其中136个(14.3%)为恶性,812个(85.7%)为良性;乳头状癌是最常见的恶性甲状腺结节(81.6%)。
临床应用与阅片要点
- TI-RADS分类的观察者间一致性良好(κ=0.636)。
- 90%的转诊临床医生接受TI-RADS。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess diagnostic validity and reproducibility of Thyroid Imaging Reporting and Data System (TI-RADS) for interpretation of thyroid nodules by thyroid ultrasonography (US).
METHOD: A prospective multicentre study initially included 557 patients with clinically suspected thyroid nodules. After exclusion, a final cohort of 380 patients with 948 thyroid nodules detected by US were enrolled. Based on American College of Radiology (ACR) TI-RADS, three radiologists analysed all US examinations independently and assigned a TI-RADS category to each thyroid nodule. The final diagnosis was based on cytology which was used as reference standard for calculating diagnostic performance of TI-RADS for predicting malignant thyroid nodules. The Fleiss and weighted kappa (κ) statistics were applied to assess inter-observer agreement of morphological features and TI-RADS scoring results for thyroid nodules. Additionally, we made a simple screening among referring clinicians to assess the clinical response to application of TI-RADS.
RESULTS: A total of 948 thyroid nodules were evaluated; 136 (14.3%) were malignant, and 812 (85.7%) were benign. The papillary carcinoma was the most common malignant thyroid nodules (81.6%). The best cut-off value for predicting malignant thyroid nodules was > TR3. On a lesion-based analysis, the TI-RADS had a sensitivity, specificity, and an accuracy of 98.3%, 90.9%, and 92.1%, respectively when regarding those thyroid nodules classified as > TR3 for predicting malignancy. The inter-observer agreement of the TI-RADS category was good (κ = 0.636). Ninety percent of referring clinicians accept TI-RADS.
CONCLUSIONS: TI-RADS improves diagnostic performance of US for predicting malignant thyroid nodules with high validity and high reproducibility.
引用
- Basha MAA, Alnaggar AA, Refaat R, et al. The validity and reproducibility of the thyroid imaging reporting and data system (TI-RADS) in categorization of thyroid nodules: Multicentre prospective study. Eur J Radiol. 2019. PMID: 31307646. doi:10.1016/j.ejrad.2019.06.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。