文献速递乳腺MR

最大斜率:基于k空间加权图像对比(KWIC)的乳腺超快动态增强MRI所得动力学参数的诊断效能

Diagnostic performance of maximum slope: A kinetic parameter obtained from ultrafast dynamic contrast-enhanced magnetic resonance imaging of the breast using k-space weighted image contrast (KWIC).
PubMed 文献 · Eur J Radiol · 2019-06-12

本研究纳入138个乳腺强化病灶(90个恶性、48个良性),比较超快DCE MRI所得最大斜率(MS)与标准DCE MRI所得廓清指数(WI)及BI-RADS分类的诊断效能。MS的AUC为0.81,与WI的0.79相当(P=0.81),但低于BI-RADS分类的0.96(P<0.001);MS敏感度91.1%(82/90)高于WI的87.8%(79/90),两者特异度均为62.5%(30/48)。作者认为MS是鉴别乳腺良恶性病灶有前景的动力学参数,且扫描时间缩短。

要点

  • 超快DCE MRI的MS诊断乳腺良恶性病灶的AUC为0.81,与标准DCE MRI的WI(0.79)相当。
  • MS敏感度为91.1%(82/90),WI为87.8%(79/90),两者特异度均为62.5%(30/48)。
  • BI-RADS分类AUC为0.96,高于MS的0.81(P<0.001)。

核心结论

  • 超快DCE MRI所得MS是鉴别乳腺良恶性病灶有前景的动力学参数,且扫描时间缩短。

研究设计与样本

  • 研究纳入138个对比增强病灶(90个恶性、48个良性),评估MS、WI与BI-RADS分类的诊断效能,采用ROC分析比较AUC。
  • 超快DCE MRI采用k空间加权图像对比(KWIC),于钆剂注射后0-1分钟采集(3.75秒/帧,共16帧),随后行标准DCE MRI(60秒/帧,共3帧)。
  • MS基于KWIC时间序列计算,单位为百分比相对强化每秒(%/s);WI为半定量参数,基于标准DCE MRI早期与延迟期信号强度变化计算。

关键影像表现/征象

  • 原文未报告具体影像征象,仅报告MS、WI与BI-RADS分类的诊断效能数值。

诊断标准与关键数值

  • MS诊断乳腺良恶性病灶的AUC为0.81,WI为0.79,两者比较P=0.81。
  • BI-RADS分类AUC为0.96,高于MS的0.81(P<0.001)。
  • MS敏感度为91.1%(82/90),WI为87.8%(79/90),两者特异度均为62.5%(30/48)。

临床应用与阅片要点

  • 原文未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare the diagnostic performance of the kinetic parameter maximum slope (MS) in breast lesions obtained by ultrafast dynamic contrast-enhanced magnetic resonance imaging (DCE MRI) of the contrast wash-in period with that of the washout index (WI) derived from standard DCE MRI and that of the Breast Imaging Reporting and Data System (BI-RADS) category.

MATERIALS AND METHODS: In total, 138 contrast enhanced lesions (90 malignant, 48 benign) were evaluated. Ultrafast DCE MRI images were acquired using a k-space-weighted image contrast (KWIC), obtained 0-1 min after gadolinium injection (3.75 s/frame; 16 frames) and followed by standard DCE MRI (60 s/frame, 3 frames). MS was calculated for the KWIC time series as percentage relative enhancement per second (%/s). As a semi-quantitative parameter for the standard DCE MRI time series, WI was evaluated using the change in signal intensity between early and delayed phases. The diagnostic performance (malignant/benign differentiation) of MS, WI, and BI-RADS category was compared by ROC analysis using the area under the curve (AUC).

RESULTS: The AUC of MS was as good as that of WI (0.81 vs. 0.79, respectively; P = 0.81), yet inferior to the BI-RADS category (0.81 vs. 0.96, respectively; <0.001). MS tended to have higher sensitivity (91.1% [82/90]) compared with WI (87.8% [79/90]) with same specificity (62.5% [30/48]).

CONCLUSIONS: MS obtained by ultrafast DCE MRI of the breast is a promising kinetic parameter in the differential diagnosis of malignant and benign breast lesions with decreased scanning time.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Ohashi A, Kataoka M, Kanao S, et al. Diagnostic performance of maximum slope: A kinetic parameter obtained from ultrafast dynamic contrast-enhanced magnetic resonance imaging of the breast using k-space weighted image contrast (KWIC). Eur J Radiol. 2019. PMID: 31324411. doi:10.1016/j.ejrad.2019.06.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。