文献速递乳腺乳腺X线

反转对比增强乳腺摄影的展示协议可获相似诊断性能并缩短阅片时间

Reversal of the hanging protocol of Contrast Enhanced Mammography leads to similar diagnostic performance yet decreased reading times.
PubMed 文献 · Eur J Radiol · 2019-05-15

研究将27名乳腺放射科医生随机分入LE-RC、RC-LE和FFDM三组,用眼动追踪技术评估30例(9例恶性)乳腺影像的阅片过程与诊断性能。RC-LE组视觉搜索指标与LE-RC组相同,阅片时间缩短31%,诊断性能相似;对比增强乳腺摄影诊断性能优于全视野数字乳腺摄影,作者推荐临床与培训采用RC-LE展示协议。

要点

  • RC-LE与LE-RC展示协议诊断性能相似,但RC-LE阅片时间缩短31%。
  • 对比增强乳腺摄影诊断性能优于全视野数字乳腺摄影(F(2,26)=16.1,P<.001)。
  • 恶性病灶在重组图像上被解读得更快,作者推荐临床实践和培训采用RC-LE展示协议。

核心结论

  • 反转展示协议(RC-LE)与常规LE-RC诊断性能相似,阅片时间快三分之一,作者推荐用于临床实践和培训。
  • 对比增强乳腺摄影诊断性能再次优于全视野数字乳腺摄影。

研究设计与样本

  • 研究为随机分组设计,27名乳腺放射科医生被随机分入LE-RC、RC-LE和FFDM三个阅片组。
  • 使用30例病例(其中9例恶性),以眼动追踪记录注视次数、净注视时间和首次注视恶性病灶时间,并测量每幅图像阅片时间。
  • 参与者点击可疑病灶以计算敏感度和特异度,并计算ROC曲线下面积(AUC)。

诊断标准与关键数值

  • RC-LE组视觉搜索指标与LE-RC组相同,t(16)=-1.45,P=.17或更高P值。
  • RC-LE组阅片时间较LE-RC组缩短31%,t(16)=-2.20,P=.04。
  • RC-LE组诊断性能与LE-RC组相似,t(13.2)=-1.39,P=.20或更高P值。
  • 对比增强乳腺摄影诊断性能优于全视野数字乳腺摄影,F(2,26)=16.1,P<.001。
  • 三组平均阅片时间无差异,F(2,25)=3.15,P=.06。

临床应用与阅片要点

  • 作者推荐临床实践和培训中采用RC-LE展示协议。
  • 重组图像上异常被解读得更快,阅片过程在重组图像上比低能图像更高效。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Contrast-enhanced mammography (CEM) was found superior to Full-Field Digital Mammography (FFDM) for breast cancer detection. Current hanging protocols show low-energy (LE, similar to FFDM) images first, followed by recombined (RC) images. However, evidence regarding which hanging protocol leads to the most efficient reading process and highest diagnostic performance is lacking. This study investigates the effects of hanging-protocol ordering on the reading process and diagnostic performance of breast radiologists using eye-tracking methodology. Furthermore, it investigates differences in reading processes and diagnostic performance between LE, RC and FFDM images.

MATERIALS AND METHODS: Twenty-seven breast radiologists were randomized into three reading groups: LE-RC (commonly used hangings), RC-LE (reversed hangings) and FFDM. Thirty cases (nine malignant) were used. Fixation count, net dwell time and time-to-first fixation on malignancies as visual search measures were registered by the eye-tracker. Reading time per image was measured. Participants clicked on suspicious lesions to determine sensitivity and specificity. Area-under-the-ROC-curve (AUC) values were calculated.

RESULTS: RC-LE scored identical on visual search measures, t(16)= -1.45, p = .17 or higher-p values, decreased reading time with 31%, t(16)= -2.20, p = .04, while scoring similar diagnostic performance compared to LE-RC, t(13.2) = -1.39, p - .20 or higher p-values. The reading process was more efficient on RC compared to LE. Diagnostic performance of CEM was superior to FFDM; F (2,26) = 16.1, p < .001. Average reading time did not differ between the three groups, F (2,25) = 3.15, p = .06.

CONCLUSION: The reversed CEM hanging protocol (RC-LE) scored similar on diagnostic performance compared to LE-RC, while reading time was a third faster. Abnormalities were interpreted quicker on RC images. A RC-LE hanging protocol is therefore recommended for clinical practice and training. Diagnostic performance of CEM was (again) superior to FFDM.

来源:Eur J Radiol,查看原文。版权归原作者所有。