活检证实的乳腺癌3T磁共振波谱:胆碱峰是否与预后因素相关
研究纳入102例活检证实的乳腺癌患者,于3T行单体素氢质子磁共振波谱(H-MRS),以胆碱峰信噪比≥2为阳性,比较波谱结果与肿瘤大小、核分级、Ki-67、激素受体状态及Her2表达的关系。胆碱峰阳性68/102例(66.67%),与更高肿瘤分级、更高Ki-67值及更大病灶尺寸显著相关(均P<0.0001),与luminal亚组无显著关联。作者认为3T乳腺H-MRS可作为获取肿瘤生物学信息、预测侵袭性的附加工具,结果需在标准化更大规模研究中验证。
要点
- 胆碱峰信噪比≥2定义为H-MRS阳性,102例中68例(66.67%)可检出总胆碱升高。
- 胆碱峰阳性与更高核分级、更高Ki-67值及更大病灶尺寸显著相关(均P<0.0001)。
- 胆碱峰与luminal亚组无显著关联,但非luminal A病变中高胆碱水平更常见。
核心结论
- 3T乳腺H-MRS检测到总胆碱升高与生物学侵袭性乳腺癌表型(大尺寸、3级、高Ki-67值)相关,可作为获取乳腺癌生物学信息、预测肿瘤侵袭性的附加工具,结果需在标准化更大规模研究中验证。
研究设计与样本
- 前瞻性研究,102例活检证实乳腺癌(BI-RADS 6病变),行3T乳腺MR成像,T1加权序列后采用PRESS水抑制序列(BREASE)行单体素H-MRS,数据取自涵盖病变的单个矩形感兴趣区,图像与波谱由2名放射科医生共识评估。
诊断标准与关键数值
- H-MRS阳性判定标准为胆碱峰信噪比≥2;总胆碱可检出68/102例(66.67%),不可检出34/102例(33.33%)。
临床应用与阅片要点
- 作者认为3T乳腺H-MRS可作为附加工具,用于获取乳腺癌生物学信息并预测肿瘤侵袭性;胆碱峰阳性与更大病灶尺寸、更高核分级及更高Ki-67值相关。
局限性
- 作者指出结果需在标准化更大规模研究中验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The role of functional techniques, such as magnetic resonance spectroscopy (H-MRS), as noninvasive tools to increase breast MR imaging reliability has been widely investigated during the last 2 decades. Considering the growing interest in tumor biology and its influence on functional parameters, the aim of this study was to investigate the relationship between H-MRS parameters and breast cancer biomarkers and to evaluate whether the results of H-MRS at 3 T can correlate with established breast cancer prognostic factors in our clinical experience.
MATERIALS AND METHODS: One hundred two patients with biopsy-proven breast cancer underwent 3 T breast MR imaging. Single-voxel H-MRS was performed after the T1-weighted sequence, using a PRESS water-suppressed sequence (BREASE). Data were collected from a single rectangular volume of interest that encompassed the lesion. Magnetic resonance images and spectra of 102 Breast Imaging Reporting and Data System 6 lesions were prospectively evaluated by 2 radiologists in consensus. H-MRS results were considered positive if the choline peak signal-to-noise ratio was 2 or higher. H-MRS findings were then compared with morphological features and to histological findings, such as lesion size, nuclear grade, Ki-67, hormone receptor status, and Her2 expression.
RESULTS: Elevated levels of total choline were detectable in 68/102 cases (66.67%) and undetectable in 34/102 (33.33%). A statistically significant association between the presence of choline peak and higher tumor grading (P < 0.0001), greater Ki-67 value (P < 0.0001), and larger lesion size (P < 0.0001) was found. No statistically significant associations were observed between choline peak and the luminal subgroups, even if higher levels of choline were more frequent in nonluminal A lesions.
CONCLUSIONS: Our study confirms that 3 T breast H-MRS can be a valid additional tool to obtain further information about breast cancer biology and to predict tumor aggressiveness, because the detection of elevated levels of total choline in the spectrum is associated with a biologically aggressive breast cancer phenotype (large dimensions, grade 3, high values of Ki-67). Our results need to be validated in standardized larger-scale studies.
引用
- Galati F, Luciani ML, Caramanico C, et al. Breast Magnetic Resonance Spectroscopy at 3 T in Biopsy-Proven Breast Cancers: Does Choline Peak Correlate With Prognostic Factors? Invest Radiol. 2019. PMID: 31356383. doi:10.1097/RLI.0000000000000597
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。