双时相FDG PET/CT识别乳腺癌腋窝淋巴结转移
该回顾性研究纳入826例乳腺癌患者,于FDG给药后1小时和2小时行PET/CT,计算腋窝淋巴结SUVmax1、SUVmax2及滞留指数。285例(34.5%)存在腋窝淋巴结转移,SUVmax1与SUVmax2诊断准确性相当,SUVmax1敏感度74.7%、特异度83.4%;在533例T1-2且无淋巴结肿大的患者中,SUVmax1阴性预测值为86.8%。
要点
- 腋窝淋巴结SUVmax1与延迟相SUVmax2诊断准确性相当,标准PET/CT即可准确识别腋窝淋巴结转移。
- SUVmax1诊断腋窝淋巴结转移的敏感度为74.7%,特异度为83.4%。
- T1-2期且无淋巴结肿大的乳腺癌患者中,腋窝SUVmax1阴性预测值为86.8%。
核心结论
- 延迟相成像识别腋窝淋巴结转移的准确性等同于标准PET/CT;PET/CT对淋巴结转移的高阴性预测值有助于避免T1-2期且无淋巴结肿大乳腺癌患者的手术腋窝评估。
研究设计与样本
- 回顾性研究,共纳入826例乳腺癌患者,治疗前于FDG给药后1小时和2小时行18F-FDG PET/CT,计算腋窝淋巴结SUVmax1、SUVmax2及滞留指数,以病理为参考标准。
诊断标准与关键数值
- 腋窝淋巴结SUVmax1诊断腋窝淋巴结转移的敏感度为74.7%,特异度为83.4%。
- 有淋巴结转移患者的中位腋窝SUVmax1、SUVmax2和滞留指数分别为1.5、1.6和7.7,无转移患者分别为0.6、0.5和-3.7(均p < 0.001)。
- 在533例T1-2期且无淋巴结肿大的乳腺癌患者中,101例(19.0%)有病理淋巴结受累,腋窝SUVmax1的阴性预测值为86.8%。
临床应用与阅片要点
- 腋窝SUVmax1与延迟相SUVmax2诊断准确性相当,标准PET/CT即可用于评估腋窝淋巴结转移。
- SUVmax1和滞留指数均为淋巴结转移的独立预测因素,当SUVmax1显著增高时,滞留指数阳性提示腋窝淋巴结受累。
- 在T1-2期且无淋巴结肿大的乳腺癌患者中,腋窝SUVmax1的高阴性预测值有助于避免手术腋窝评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The aim of this study was to assess the diagnostic performance of dual-phase 18F-FDG PET/CT in detecting axillary lymph node metastasis in patients with breast cancer. MATERIALS AND METHODS. A total of 826 patients with breast cancer were retrospectively evaluated. PET/CT scans were performed 1 hour and 2 hours after FDG administration before treatment. The maximum standardized uptake value (SUVmax) in the axillary lymph node at both time points (hereafter referred to as SUVmax1 and SUVmax2, respectively) and the retention index (RI) were calculated. RESULTS. Axillary lymph node metastasis was detected in 285 of 826 patients (34.5%). The median axillary SUVmax1, SUVmax2, and RI in patients with nodal metastasis were higher than those in patients without metastasis (1.5 vs 0.6, 1.6 vs 0.5, and 7.7 vs -3.7, respectively; all p < 0.001). The diagnostic accuracy of axillary SUVmax1 and SUVmax2 was equivalent, and the sensitivity and specificity of SUVmax1 were 74.7% and 83.4%, respectively. Although the performance of the axillary RI was inferior to that of SUVmax1 and SUVmax2, both the SUVmax and the RI were independent predictors of nodal metastasis, and a positive RI suggested axillary lymph node involvement when the SUVmax1 was significantly high. Of 533 patients with category T1-2 breast cancer without lymph node swelling, 101 (19.0%) had pathologic lymph node involvement; the negative predictive value of axillary SUVmax1 was 86.8%. CONCLUSION. Delayed phase imaging identified axillary lymph node metastasis as accurately as standard PET/CT. A high negative predictive value of PET/CT for the detection of nodal metastasis is helpful to avoid surgical axillary assessment in patients with category T1-2 breast cancer without lymph node swelling.
引用
- Sasada S, Masumoto N, Kimura Y, et al. Identification of Axillary Lymph Node Metastasis in Patients With Breast Cancer Using Dual-Phase FDG PET/CT. AJR Am J Roentgenol. 2019. PMID: 31339353. doi:10.2214/AJR.19.21373
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。