文献速递乳腺乳腺X线

对比增强能谱乳腺X线摄影在乳腺癌术后评估中的作用

The role of contrast-enhanced spectral mammography in the evaluation of the postoperative breast cancer.
PubMed 文献 · Clin Radiol · 2019-07-06

前瞻性分析76例乳腺癌术后女性,评估对比增强能谱乳腺X线摄影(CESM)检出术后乳腺恶性的效用。70例可分析,恶性检出率48.6%。传统乳腺X线摄影敏感度50%、特异度22%、准确率35.7%;CESM敏感度91.17%、特异度75%、准确率82.85%。

要点

  • 乳腺癌术后术床强化常见,CESM有助于区分恶性与术后良性改变。
  • 传统乳腺X线摄影在术后乳腺敏感度50%、特异度22%,假阴性17/70、假阳性28/70。
  • CESM诊断效能优于传统乳腺X线摄影,敏感度91.17%、特异度75%。

核心结论

  • CESM是一种可信的技术,可与传统乳腺X线摄影联合用于乳腺癌术后乳腺的筛查。

研究设计与样本

  • 前瞻性分析76例乳腺癌术后女性,70例符合数据分析;CESM静脉注射对比剂后采用低能量(22–33 kVp)和高能量(44–49 kVp)曝光。

关键影像表现/征象

  • 术床强化见于40个(57.14%)病灶。
  • 评估乳腺异常时关注对比剂摄取的存在、形态和模式。

诊断标准与关键数值

  • 参考标准为疑似恶性病例的Tru-Cut活检或手术活检组织病理学,良性病例为随访无异常。
  • 传统乳腺X线摄影敏感度50%、特异度22%、阳性预测值37.7%、阴性预测值32%、准确率35.7%。
  • CESM敏感度91.17%、特异度75%、阳性预测值77.5%、阴性预测值90%、准确率82.85%。

临床应用与阅片要点

  • 作者认为CESM可与传统乳腺X线摄影联合用于乳腺癌术后乳腺的筛查。
  • 阅片时需评估术床强化的存在、形态和模式,以辅助鉴别恶性病变。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To assess the utility of contrast-enhanced spectral mammography (CESM) to detect malignancy in the postoperative breast of cancer patients.

MATERIALS AND METHODS: The study was a prospective analysis of 76 women following operations for breast cancer. CESM was performed with low (22-33 kVp) and high (44-49 kVp) energy exposures after intravenous injection of contrast agent. Breast abnormalities were evaluated regarding the presence, morphology, and pattern of contrast medium uptake. The reference standard was histopathology of the Tru-Cut biopsy or surgical biopsy in cases where malignancy was suspected and absence of abnormality at follow-up sessions in benign cases.

RESULTS: Seventy cases were eligible for data analysis, and malignancy was detected in 48.6% (n=34/70). Enhancement at the operative bed was observed in 40 (57.14%) lesions. At traditional mammography, the diagnosis was false negative in 17/70 and false positive in 28/70 lesions, and presented a low sensitivity of 50%, a very low specificity of 22%, a positive predictive value of 37.7%, a negative predicative value of 32%, and an accuracy of 35.7%. CESM enhanced the performance of mammography and produced a sensitivity of 91.17%, a specificity of 75%, a positive predictive value of 77.5%, a negative predictive value of 90%, and an accuracy of 82.85%.

CONCLUSION: CESM is a credible technique that could be used in conjunction with the traditional mammogram to screen for cancer in the postoperative breast.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Helal MH, Mansour SM, Ahmed HA, et al. The role of contrast-enhanced spectral mammography in the evaluation of the postoperative breast cancer. Clin Radiol. 2019. PMID: 31285035. doi:10.1016/j.crad.2019.06.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。