文献速递乳腺MR

背景实质强化对乳腺MRI筛查诊断性能的影响

Impact of Background Parenchymal Enhancement on Diagnostic Performance in Screening Breast MRI.
PubMed 文献 · Acad Radiol · 2019-07-18

本研究回顾性分析2011至2014年本机构连续4686例乳腺MRI筛查,将背景实质强化(BPE)分为低度(轻微/轻度)与高度(中度/显著)两组,比较诊断性能。调整混杂因素后,高度BPE组异常解释率显著高于低度BPE组(13% vs 7%,调整OR 1.37,95%CI 1.03–1.82),而癌检出率、阳性预测值、敏感度及特异度两组无显著差异(P>0.05)。

要点

  • 高度BPE组筛查MRI异常解释率为13%,低度BPE组为7%,调整后OR 1.37(95%CI 1.03–1.82)。
  • 调整混杂因素后,两组癌检出率、阳性预测值、敏感度及特异度均无显著差异(P>0.05)。
  • BPE升高与异常解释率增加相关,但未影响癌检出率、敏感度或特异度。

核心结论

  • 筛查乳腺MRI上较高的背景实质强化与较高的异常解释率相关,对癌检出率、敏感度或特异度无影响。

研究设计与样本

  • 回顾性分析本机构2011至2014年连续乳腺MRI筛查,共4686例检查(2446名女性),经机构审查委员会批准并符合HIPAA要求,以低度BPE为参照组,采用Pearson χ2检验及logistic回归调整年龄、筛查指征、乳腺X线密度、既往MRI可用性及检查年份等混杂因素。

诊断标准与关键数值

  • BPE分为低度(轻微或轻度)与高度(中度或显著);低度组3975例(85%),高度组711例(15%)。
  • 高度BPE组异常解释率为13%(89/711),低度BPE组为7%(295/3975),调整OR 1.37(95%CI 1.03–1.82)。
  • 调整后癌检出率、阳性预测值、敏感度及特异度两组间无显著差异(P>0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate the impact of background parenchymal enhancement (BPE) on diagnostic performance in screening breast magnetic resonance imaging (MRI).

MATERIALS AND METHODS: Consecutive screening breast MRIs performed at our institution from 2011 to 2014 were reviewed in a HIPAA-compliant manner with institutional review board approval. BPE was extracted from radiology reports and examinations grouped into minimal/mild (lower) or moderate/marked (higher) BPE. Performance measures were compared between the two groups with Pearson's χ2 test and with logistic regression to adjust for possible confounders of age, screening indication, mammographic density, available prior MRI, and examination year, using lower BPE as the reference group.

RESULTS: For 4686 screening MRIs performed in 2446 women, BPE was reported as minimal or mild for 3975 (85%) examinations and moderate or marked for 711(15%). Following logistic regression to adjust for multiple confounders, abnormal interpretation rate (AIR) significantly differed between the two BPE groups. AIR was 13% (89/711) in the higher BPE group versus 7% (295/3975) in the lower BPE group with an adjusted odds ratio of 1.37 (95% confidence interval: 1.03, 1.82). After adjustment, all other performance metrics, including cancer detection rate, positive predictive value, sensitivity, and specificity did not significantly differ between the two BPE groups (P > 0.05).

CONCLUSION: Higher BPE on screening MRI is associated with higher abnormal interpretation rate, with no impact on cancer detection rate, sensitivity, or specificity.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Sippo DA, Rutledge GM, Mercaldo SF, et al. Impact of Background Parenchymal Enhancement on Diagnostic Performance in Screening Breast MRI. Acad Radiol. 2019. PMID: 31327575. doi:10.1016/j.acra.2019.06.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。