乳腺癌中计算扩散加权成像与体素级计算扩散加权成像的定量评价
回顾性纳入130例乳腺癌患者(130个恶性病灶),比较不同低b值组合生成的计算扩散加权成像(cDWI,b值1500–4000 s/mm²)与体素级计算扩散加权成像(vcDWI)的信噪比和对比度。vcDWI对比度最高,cDWI对比度随b值升高而改善;除cDWI1000和vcDWI外,其余cDWI信噪比均显著低于实测DWI。
要点
- vcDWI在乳腺癌中对比度最高,可能有助于更简易地检出病灶。
- cDWI对比度随b值升高而改善,b值1500–2000 s/mm²区间信噪比与对比度变化趋于交汇。
- 除cDWI1000外,各cDWI对比度均显著高于实测DWI,信噪比则随b值升高而降低。
核心结论
- vcDWI获得最高对比度,可能是更简易检出乳腺癌的有前景方法。
研究设计与样本
- 回顾性研究纳入130例患者(年龄25–70岁,平均48.6±10.5岁)的130个恶性病灶,均在穿刺活检或手术前接受包含DWI序列的MRI检查;由两名经验丰富的放射科医师独立计算并比较各图像集的信噪比和对比度。
诊断标准与关键数值
- 从低b值0/600、0/800或0/1000 s/mm²的实测DWI生成b值为1500、2000、2500、3000、3500、4000 s/mm²的cDWI及vcDWI;对比度乘以100得CR100用于与信噪比比较。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the value of computed diffusion-weighted imaging (cDWI) and voxelwise computed diffusion-weighted imaging (vcDWI) in breast cancer.
METHODS: This retrospective study involved 130 patients (age range, 25-70 years; mean age ± standard deviation, 48.6 ± 10.5 years) with 130 malignant lesions, who underwent MRI examinations, including a DWI sequence, prior to needle biopsy or surgery. cDWIs with higher b-values of 1500, 2000, 2500, 3000, 3500, and 4000 s/mm2, and vcDWI were generated from measured (m) DWI with two lower b-values of 0/600, 0/800, or 0/1000 s/mm2. The signal-to-noise ratio (SNR) and contrast ratio (CR) of all image sets were computed and compared among different DWIs by two experienced radiologists independently. To better compare the CR with the SNR, the CR value was multiplied by 100 (CR100).
RESULTS: The CR of vcDWI, and cDWIs, except for cDWI1000, differed significantly from that of measured diffusion-weighted imaging (mDWI) (cDWI1000: CR = 0.4904, p = 0.394; cDWI1500: CR = 0.5503, p = 0.006; cDWI2000: CR = 0.5889, p < 0.001; cDWI2500: CR = 0.6109, p < 0.001; cDWI3000: mean = 0.6214, p < 0.001; cDWI3500: CR = 0.6245, p < 0.001; cDWI4000: CR = 0.6228, p < 0.001). The vcDWI provided the highest CR, while the CRs of all cDWI image sets improved with increased b-values. The SNR of neither cDWI1000 nor vcDWI differed significantly from that of mDWI, but the mean SNRs of the remaining cDWIs were significantly lower than that of mDWI. The SNRs of cDWIs declined with increasing b-values, and the initial decrease at low b-values was steeper than the gradual attenuation at higher b-values; the CR100 rose gradually, and the two converged on the b-value interval of 1500-2000 s/mm2 .
CONCLUSIONS: The highest CR was achieved with vcDWI; this could be a promising approach easier detection of breast cancer.
ADVANCES IN KNOWLEDGE: This study comprehensively compared and evaluated the value of the emerging post-processing DWI techniques (including a set of cDWIs and vcDWI) in breast cancer.
引用
- Cheng Q, Ye S, Fu C, et al. Quantitative evaluation of computed and voxelwise computed diffusion-weighted imaging in breast cancer. Br J Radiol. 2019. PMID: 31291125. doi:10.1259/bjr.20180978
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。