早孕期脐静脉血流在预测大于胎龄儿中的作用
这项匹配病例对照研究纳入964例单胎妊娠,在11+0至13+6周测量脐静脉血流(UVBF)等指标。大于胎龄儿(LGA)组的UVBF Z评分和脐静脉时间平均最大速度(TAMXV)Z评分较高,子宫动脉搏动指数中位数倍数(MoM)较低。将UVBF Z评分加入包含产次、BMI和PAPP-A MoM的多参数模型后,预测LGA的AUC从0.72提高至0.79。
要点
- LGA组早孕期UVBF Z评分中位数1.3,高于对照组的0.1(P ≤ 0.001)。
- LGA组脐静脉TAMXV Z评分中位数0.8,高于对照组的0.0(P ≤ 0.001)。
- 多参数模型加入UVBF Z评分后预测LGA的AUC为0.79,高于未加入时的0.72。
核心结论
- 在11-14周超声检查时测量的UVBF与LGA及出生体重>4000 g独立相关并具有预测价值;将UVBF测量加入包含母亲(产次和BMI)和生化(PAPP-A)参数的多参数模型,可提高产前筛查LGA的诊断准确性。
研究设计与样本
- 匹配病例对照研究,单中心4年期间纳入964例单胎妊娠(241例LGA和723例对照),病例为出生体重>当地标准第90百分位,对照为第10-90百分位,按母亲年龄和孕龄1:3匹配;所有病例行子宫动脉和脐静脉多普勒评估,测量脐静脉直径、TAMXV和UVBF,并计算Z评分。
诊断标准与关键数值
- LGA组UV-TAMXV Z评分中位数0.8(IQR 0.4-1.5) vs 对照组0.0(IQR -0.3至0.5),P ≤ 0.001;LGA组UVBF Z评分中位数1.3(IQR 0.8-1.9) vs 对照组0.1(IQR -0.4至0.4),P ≤ 0.001;脐静脉直径Z评分中位数两组差异无统计学意义(P = 0.56);LGA组子宫动脉搏动指数MoM中位数0.94(IQR 0.78-1.12) vs 对照组1.02(IQR 0.84-1.19),P = 0.04。
临床应用与阅片要点
- 多变量logistic回归显示母亲BMI(aOR 1.2,95%CI 1.1-1.7;P < 0.001)、产次(aOR 1.4,95%CI 1.2-1.6;P < 0.001)、PAPP-A MoM(aOR 1.1,95%CI 1.0-1.6;P = 0.04)和UVBF Z评分(aOR 1.6,95%CI 1.1-1.9;P < 0.001)与LGA独立相关;整合产次、BMI和PAPP-A MoM的多参数模型预测LGA的AUC为0.72(95%CI 0.67-0.76),加入UVBF Z评分后AUC为0.79(95%CI 0.75-0.83;P = 0.03),该模型预测出生体重>4000 g的AUC为0.83(95%CI 0.75-0.93)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To describe umbilical vein (UV) hemodynamics at 11 + 0 to 13 + 6 weeks of gestation in pregnancies delivering a large-for-gestational-age (LGA) neonate, and to build a multiparametric model, including pregnancy and ultrasound characteristics in the first trimester, that is able to predict LGA at birth.
METHODS: This was a matched case-control study, of singleton pregnancies that underwent ultrasound examination at 11 + 0 to 13 + 6 weeks for aneuploidy screening, at a single center over a 4-year period. Cases were women who delivered a neonate with birth weight (BW) > 90th centile for gestational age and sex, according to local birth-weight standards, while controls were those who delivered a neonate with BW ranging between the 10th and 90th centiles, matched for maternal and gestational age, at a ratio of 1:3. Each included case underwent Doppler assessment of the uterine arteries and UV, including measurement of its diameter, time-averaged maximum velocity (TAMXV) and UV blood flow (UVBF). UVBF and its components were expressed as Z-scores. Fisher's exact test and Mann-Whitney U-test were used to compare differences in maternal biomarkers and ultrasound characteristics between pregnancies complicated by LGA and controls. Logistic regression and receiver-operating-characteristics (ROC) curve analyses were carried out to identify independent predictors of LGA and to build a multiparametric prediction model integrating different maternal, pregnancy and ultrasound characteristics. Subgroup analysis was also performed, considering women who delivered a neonate with BW > 4000 g.
RESULTS: In total, 964 pregnancies (241 with LGA at birth and 723 without) were included in the study. In LGA pregnancies compared with controls, UV-TAMXV Z-score (0.8 (interquartile range (IQR), 0.4-1.5) vs 0.0 (IQR, -0.3 to 0.5); P ≤ 0.001) and UVBF Z-score (1.3 (IQR, 0.8-1.9) vs 0.1 (IQR, -0.4 to 0.4); P ≤ 0.001) were higher, while there was no difference in median UV diameter Z-score (P = 0.56). Median uterine artery pulsatility index multiples of the median (MoM; 0.94 (IQR, 0.78-1.12) vs 1.02 (IQR, 0.84-1.19); P = 0.04) was significantly lower in LGA pregnancies. On multivariate logistic regression analysis, maternal body mass index (BMI; adjusted odds ratio (aOR), 1.2 (95% CI, 1.1-1.7); P < 0.001), parity (aOR, 1.4 (95% CI, 1.2-1.6); P < 0.001), pregnancy-associated plasma protein-A (PAPP-A) MoM (aOR, 1.1 (95% CI, 1.0-1.6); P = 0.04) and UVBF Z-score (aOR, 1.6 (95% CI, 1.1-1.9); P < 0.001) were associated independently with LGA. A multiparametric model integrating parity, BMI and PAPP-A MoM provided an area under the ROC curve (AUC) of 0.72 (95% CI, 0.67-0.76) for the prediction of LGA. The addition of UVBF Z-score to this model significantly improved the prediction of LGA provided by maternal and biochemical factors, with an AUC of 0.79 (95% CI, 0.75-0.83; P = 0.03). Similarly, the model incorporating UVBF Z-score predicted BW > 4000 g with an AUC of 0.83 (95% CI, 0.75-0.93).
CONCLUSIONS: UVBF measured at the time of the 11-14-week scan is associated independently with, and is predictive of, LGA and BW > 4000 g. Adding measurement of UVBF to a multiparametric model that includes maternal (parity and BMI) and biochemical (PAPP-A) parameters improves the diagnostic accuracy of prenatal screening for LGA at birth. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.
引用
- Rizzo G, Mappa I, Bitsadze V, et al. Role of first-trimester umbilical vein blood flow in predicting large-for-gestational age at birth. Ultrasound Obstet Gynecol. 2020. PMID: 31343791. doi:10.1002/uog.20408
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。