本研究为回顾性研究,纳入2014年某三级泌尿妇科中心399名女性,均行标准化访谈、临床检查及静息与盆底肌收缩状态下的三维/四维经会阴超声,测量肛门外括约肌与内括约肌缺损角度。结果显示单项经会阴断层超声切面上的残余缺损角度与肛门失禁症状、困扰评分及St Mark失禁评分仅呈弱相关,预测价值低,尚不足以验证腔内超声所用的30°缺损角度截断值。

要点

  • 经会阴断层超声单切面括约肌残余缺损角度与肛门失禁症状仅弱相关,预测价值低。
  • ROC曲线下面积过低,无法确定缺损角度的明确截断值。
  • 在肛门外括约肌小缺损(<30°)可被忽略之前,需在高患病率人群中开展更大规模研究。

核心结论

  • 经会阴断层超声单切面上肛门外括约肌与内括约肌残余缺损与肛门失禁各项指标仅呈弱相关,单切面缺损角度预测价值差,不足以验证腔内超声所用的30°缺损角度截断值。

研究设计与样本

  • 回顾性研究,纳入2014年某三级泌尿妇科中心399名女性。
  • 所有受试者行标准化访谈(含St Mark失禁评分SMIS)、临床检查及静息与盆底肌收缩状态下的三维/四维经会阴超声。
  • 在断层超声各切面上测量肛门外括约肌与内括约肌缺损角度,分析其与肛门失禁症状、困扰评分及SMIS的关联。

诊断标准与关键数值

  • 腔内超声将括约肌缺损定义为在肛门外括约肌长度至少三分之二范围内径向延伸>30°。
  • 经会阴断层超声将显著肛门括约肌创伤定义为6个切面中至少4个切面存在缺损,该定义已被验证。
  • ROC曲线下面积过低,未能确定缺损角度的明确截断值。

局限性

  • 本研究为回顾性研究。
  • 在能够忽略经会阴超声上小于30°的肛门括约肌缺损之前,需要在肛门失禁患病率更高的人群中开展更大规模研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The anal sphincter is commonly evaluated with endoanal ultrasound. Recently, translabial ultrasound imaging has been proposed for sphincter imaging, with moderate to good correlation between the methods. An endosonographic defect is defined as one with a radial extension of > 30° in at least two-thirds of the length of the anal sphincter. This is equivalent to defining significant anal sphincter trauma on translabial tomographic ultrasound imaging (TUI) as a defect in at least four of six slices, a definition which has been validated. This study was designed to validate a residual defect angle of > 30° for the definition of significant anal sphincter trauma on translabial ultrasound.

METHODS: This was a retrospective study involving 399 women attending a tertiary urogynecology unit in 2014. All underwent a standardized interview, including determination of St Mark's fecal incontinence score (SMIS), clinical examination and 3D/4D translabial ultrasound examination with the woman at rest and on pelvic floor muscle contraction (PFMC). External (EAS) and internal (IAS) anal sphincter defect angles were measured in individual TUI slices and associations with anal incontinence symptoms, bother score and SMIS were analyzed.

RESULTS: There were weak but significant correlations of anal incontinence symptoms, bother score and SMIS with EAS and IAS defect angle, measured on images acquired with the woman at rest and on PFMC. The predictive value of single-slice defect angle on TUI was low, and areas under the receiver-operating-characteristics curves were too low to determine a distinct cut-off value for defect angle.

CONCLUSIONS: Anal sphincter residual defects on single translabial TUI slices are weakly associated with measures of anal incontinence. Single-slice defect angle is too poor a predictor to allow validation of the 30° defect angle cut-off used in endoanal ultrasound. Larger studies in populations with a higher prevalence of anal incontinence are needed before we can disregard anal sphincter defects smaller than 30° on translabial ultrasound. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Subramaniam N, Dietz HP. What is a significant defect of the anal sphincter on translabial ultrasound? Ultrasound Obstet Gynecol. 2020. PMID: 31271480. doi:10.1002/uog.20390

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。