PubMed 文献 · Br J Radiol · 2019-07-18

这项前瞻性研究纳入230例女性共245个附件/卵巢肿块,评估MR波谱对恶性病变检测的价值。以手术病理为标准,胆碱峰(高于平均噪声水平两倍)见于72%恶性与5.4%良性肿块,准确率83%;加乳酸后准确率升至93%。恶性肿块平均Cho/Cr比值2.8显著高于良性1.2,最佳截断值1.7对应敏感度81.2%、特异度93.3%、准确率87.1%。

要点

  • 胆碱峰高于平均噪声水平两倍时,恶性肿块检出率72%、良性仅5.4%,准确率83%。
  • 联合胆碱与乳酸峰可将鉴别良恶性的准确率提升至93%。
  • Cho/Cr比值最佳截断值1.7,敏感度81.2%、特异度93.3%、准确率87.1%。

核心结论

  • 卵巢肿块MRS检查中胆碱与乳酸峰同时存在可最大限度减少良恶性分类的重叠。

研究设计与样本

  • 前瞻性研究,纳入230例女性共245个附件/卵巢肿块,肿块经初步盆腔超声发现。

关键影像表现/征象

  • 评估的波谱峰包括乳酸(Lac,1.31 ppm)、脂质(Lip,1.33 ppm)、N-乙酰天冬氨酸(2.0 ppm)、丙酮(A,2.05 ppm)、胆碱(Cho,3.23 ppm)和肌酐(Cr,3.4 ppm)。
  • 胆碱峰高于平均噪声水平两倍者占恶性肿块的72%、良性肿块的5.4%,准确率83%。
  • 将乳酸加入胆碱分析后准确率提升至93%。
  • N-乙酰天冬氨酸和丙酮是诊断复杂囊性肿块为良性畸胎瘤、子宫内膜瘤和输卵管卵巢脓肿的代谢物。

诊断标准与关键数值

  • 以手术病理为标准参照。
  • 胆碱峰高于平均噪声水平两倍用于判定恶性,准确率83%。
  • 联合胆碱与乳酸峰判定恶性,准确率93%。
  • 平均Cho/Cr比值鉴别恶性的最佳截断值为1.7,对应敏感度81.2%、特异度93.3%、阳性预测值92.9%、阴性预测值82.4%、准确率87.1%。
  • 恶性卵巢肿块平均Cho/Cr比值为2.8,良性为1.2,恶性显著高于良性。

临床应用与阅片要点

  • MRS是无对比剂、快速的MR序列,可提供组织成分信息,用于提高卵巢肿块恶性检测的敏感度和准确率。
  • 阅片时可关注胆碱峰(高于平均噪声水平两倍)与乳酸峰同时出现,以帮助减少良恶性重叠。
  • Cho/Cr比值1.7可作为鉴别良恶性的参考截断值。
  • N-乙酰天冬氨酸和丙酮可用于将复杂囊性肿块诊断为良性畸胎瘤、子宫内膜瘤和输卵管卵巢脓肿。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess the impact of MR spectroscopy (MRS) on the detection of malignancy in ovarian masses.

METHODS: This prospective work included 230 females that had 245 adnexal/ovarian masses. Tumours were spotted by preliminary pelvic ultrasound. Masses assessed by MRI, multi- or single-voxel spectroscopy. Patients' spectra were assessed for peaks of lactate (Lac, 1.31 ppm), lipid (Lip, 1.33 ppm), N-acetyl aspartate (2.0 ppm), acetone (A, 2.05 ppm), choline (Cho, 3.23 ppm) and creatinine (Cr, 3.4 ppm) and the mean values of the (Cho/Cr) ratios were performed by a semi-quantitative approach. The operative pathology served as the standard of reference.

RESULTS: Cho peak twofold higher than the average noise level was detected in 72% of the malignant and only 5.4% of the benign masses with an accuracy of 83%. Adding lactate to the choline enhanced the accuracy to 93%. The mean Cho/Cr ratios of the malignant ovarian masses (2.8) were significantly higher than that of the benign ones (1.2) . We used a receiver operating characteristic curve to determine the best cut-off value (1.7) for the mean Cho/Cr ratio to discriminate malignancy with sensitivity: 81.2%, specificity: 93.3 %, positive-predictive value: 92.9 %, negative-predictive value: 82.4% and accuracy: 87.1%.

CONCLUSION: The simultaneous presence of choline and lactate peaks in MRS examination of the ovarian masses minimizes the overlap between benign and malignant categories. N-acetyl aspartate and acetone are the metabolites for diagnosing complex cystic masses as benign teratoma, endomterioma and tubo- ovarian abscess.

ADVANCES IN KNOWLEDGE: MRS is a non-contrast based and fast MR sequence that gives an idea about tissue components could be used to improve the sensitivity and the accuracy of detecting malignancy in ovarian masses.

来源:Br J Radiol,查看原文。版权归原作者所有。