文献速递泌尿生殖妇产影像MRDSA

仰卧位磁共振排粪造影评估前腔室脱垂:与直立位排尿性膀胱尿道造影的比较

Supine magnetic resonance defecography for evaluation of anterior compartment prolapse: Comparison with upright voiding cystourethrogram.
PubMed 文献 · Eur J Radiol · 2019-05-25

回顾性比较51例有症状盆腔器官脱垂患者仰卧位MRD与直立位VCUG,MRD所测膀胱膨出程度平均低1.58 cm、尿道应变角平均高31.8度,43.3%患者膀胱膨出分级被上调,MRD膀胱膨出大小与临床脱垂症状相关。

要点

  • 仰卧位MRD较直立位VCUG测得膀胱膨出更低、尿道活动度更大。
  • MRD使43.3%患者膀胱膨出分级上调,报告需注明体位与参考线差异。
  • MRD上膀胱膨出大小与临床POP症状相关,VCUG上则未达显著。

核心结论

  • 仰卧位MRD显示的膀胱膨出和尿道活动度过高患病率及程度均显著高于直立位VCUG,并改变相当部分患者的膀胱脱垂分级;MRD膀胱膨出大小与临床脱垂症状相关。

研究设计与样本

  • IRB批准、HIPAA合规的回顾性研究,纳入51例连续的有症状盆腔器官脱垂伴下尿路症状且同时接受直立位VCUG和仰卧位MRD的患者;膀胱膨出高度在VCUG上以耻骨下缘为参考、在MRD上以耻骨尾骨线为参考,以厘米定义;静息尿道角(UAR)和应变尿道角(UAS)为尿道轴与外口垂线之间的度数;采用配对t检验和简单线性回归比较,p<0.05为显著。

关键影像表现/征象

  • MRD上膀胱膨出平均范围-2.73±1.99 cm,VCUG上为-1.16±1.75 cm。
  • MRD上平均UAS为72.29±26.45度,VCUG上为40.45±21.41度。
  • MRD上平均UAS-UAR为74.30±28.50度,VCUG上为15.70±11.27度。

诊断标准与关键数值

  • 膀胱膨出高度在VCUG上以耻骨下缘为参考点、在MRD上以耻骨尾骨线为参考点,以厘米测量。
  • 尿道活动度过高(UHM)在VCUG上见于5例(9.8%),在MRD上见于48例(94.1%)。
  • 与VCUG相比,MRD使22例(43.3%)患者膀胱膨出大小分级上调。
  • MRD上膀胱膨出大小在POP阳性患者中显著大于POP阴性患者(p=0.005),VCUG上无显著差异(p=0.06)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare utility of supine Magnetic Resonance Defecography (MRD) with upright Voiding Cystourethrogram (VCUG) for evaluation of cystocele and urethral hypermobility (UHM).

METHODS: This was an IRB-approved, HIPAA-compliant, retrospective study of 51 consecutive patients with symptomatic pelvic organ prolapse (POP) and lower urinary tract symptoms who underwent both upright VCUG and supine MRD. Cystocele height was defined in centimeters with reference to the inferior edge of the pubic bone on VCUG and the pubococcygeal line on MRD. Urethral angle at rest (UAR) and during straining (UAS) was measured in degrees between the urethral axis and a vertical line at the external meatus. Pairedt-test and simple linear regression were applied to compare VCUG and MRD data sets. p < 0.05 was considered significant.

RESULTS: The mean cystocele extent was 1.58 cm lower (more inferior to the reference point) (95% CI for the mean difference: 1.21, 1.94;p < 0.0001) on MRD (-2.73 ± 1.99 cm) than on VCUG (-1.16 ± 1.75 cm). Mean UAS on MRD (72.29 ± 26.45) was 31.8 degrees higher compared to that on VCUG (40.45 ± 21.41), (95% CI for mean difference in UAS: 37.57, 26.11; p < 0.0001). Mean UAS-UAR on MRD (74.30 ± 28.50) was 58.6 degrees higher compared to that on VCUG (15.70 ± 11.27) (95% CI for mean difference in UAS-UAR 65.94, 51.26; p < 0.0001). Cystocele size was upgraded in 22 (43.3%) patients on MRD compared to VCUG. Five (9.8%) patients demonstrated UHM on VCUG; 48 (94.1%) patients demonstrated UHM on MRD. The differences between VCUG and MRD scores persisted across the range of VCUG measurements. Cystocele size was significantly larger in POP (+) patients than in POP (-) patients on MRD (p = 0.005) but not on VCUG (p = 0.06).

CONCLUSIONS: Supine MRD demonstrates significantly higher prevalence and degree of cystocele and UHM than upright VCUG, and alters the grade of bladder prolapse in a significant portion of the patient population. Cystocele size on MRD correlates with clinical presence of prolapse symptoms.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Kumar NM, Khatri G, Christie AL, et al. Supine magnetic resonance defecography for evaluation of anterior compartment prolapse: Comparison with upright voiding cystourethrogram. Eur J Radiol. 2019. PMID: 31307659. doi:10.1016/j.ejrad.2019.05.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。