文献速递泌尿生殖技术与安全PETCT

F18氟胆碱PET/CT对新诊断前列腺癌患者术前淋巴结分期的诊断准确性:系统评价与Meta分析

Diagnostic accuracy of F18 flucholine PET/CT for preoperative lymph node staging in newly diagnosed prostate cancer patients; a systematic review and meta-analysis.
PubMed 文献 · Br J Radiol · 2019-07-05

该系统评价与Meta分析纳入7项研究共627例新诊断前列腺癌患者,评估F18氟胆碱PET/CT术前淋巴结分期的诊断准确性。汇总敏感度为0.57(95%CI 0.42-0.70),特异度为0.94(95%CI 0.89-0.97),阳性似然比10.2(95%CI 5.0-21.0),阴性似然比0.46(95%CI 0.33-0.64),诊断比值比22(95%CI 9-54)。结论认为F18氟胆碱PET/CT检测转移性淋巴结敏感度低、特异度高,仅对确认淋巴结转移(阳性时)有用。

要点

  • F18氟胆碱PET/CT术前淋巴结分期汇总敏感度0.57,特异度0.94。
  • 阳性似然比10.2、阴性似然比0.46,阳性结果对确认淋巴结转移有价值。
  • 作者认为该检查敏感度低,仅阳性时有助于确认淋巴结转移。

核心结论

  • F18氟胆碱PET/CT在新诊断前列腺癌患者中检测转移性淋巴结敏感度低、特异度高。
  • F18氟胆碱PET/CT仅对确认淋巴结转移(阳性时)有用。

研究设计与样本

  • 系统评价与Meta分析,检索PubMed和Embase自最早收录日期至2018年12月31日的研究。
  • 纳入7项研究共627例新诊断前列腺癌患者,评估F18氟胆碱PET/CT术前淋巴结分期的诊断性能。
  • 合并计算敏感度、特异度、阳性似然比(LR+)和阴性似然比(LR-),并构建汇总受试者工作特征曲线。

诊断标准与关键数值

  • 汇总敏感度为0.57(95%CI 0.42-0.70),汇总特异度为0.94(95%CI 0.89-0.97)。
  • 汇总阳性似然比为10.2(95%CI 5.0-21.0),汇总阴性似然比为0.46(95%CI 0.33-0.64)。
  • 汇总诊断比值比为22(95%CI 9-54)。

临床应用与阅片要点

  • 作者认为F18氟胆碱PET/CT仅对确认淋巴结转移(阳性时)有用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The purpose of the current study was to investiagte the diagnostic accuracy of F18 flucholine (FCH) positron emission tomography/CT (PET/CT) for pre-operative lymph node (LN) staging in newly diagnosed prostate cancer (PCa) patients using meta-analysis.

METHODS: PubMed and Embase from the earliest available date of indexing through December 31, 2018, were searched for studies evaluating the diagnostic performance of F18 FCH PET/CT for preoperative LN staging in newly diagnosed PCa. We determined the sensitivities and specificities across studies, calculated positive and negative likelihood ratios (LR + and LR-), and constructed summary receiver operating characteristic curves.

RESULTS: Across seven studies (627 patients), the pooled sensitivity was 0.57 [95% confidence interval (CI) (0.42-0.70)] and a pooled specificity of 0.94 [95% CI (0.89-0.97)]. Likelihood ratio (LR) syntheses gave an overall positive likelihood ratio (LR+) of 10.2 (95% CI; 5.0-21.0) and negative likelihood ratio (LR-) of 0.46 (95% CI; 0.33-0.64). The pooled diagnostic odds ratio was 22 (95% CI; 9-54).

CONCLUSIONS: F18 FCH PET/CT shows a low sensitivity and high specificity for the detection of metastatic LNs in patients with newly diagnosed PCa. Also, F18 FCH PET/CT is only useful for confirmation of LN metastasis (when positive) in PCa patients.

ADVANCES IN KNOWLEDGE: F18 FCH PET/CT demonstrates low sensitivity but high specificity for diagnosis of metastatic LNs in patients with newly diagnosed PCa. Also, F18 FCH PET/CT is only useful for confirmation of LN metastasis (when positive) in PCa patients.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Kim SJ, Lee SW. Diagnostic accuracy of F18 flucholine PET/CT for preoperative lymph node staging in newly diagnosed prostate cancer patients; a systematic review and meta-analysis. Br J Radiol. 2019. PMID: 31265330. doi:10.1259/bjr.20190193

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。