多参数MRI参数在不同区域前列腺癌Gleason评分与细胞密度指标中的诊断效能:定量比较
回顾性纳入225例术前行mpMRI且有全mount病理切片的前列腺癌患者,比较外周带与移行带病灶中T2信号强度比值/偏度与ADC参数对Gleason评分及细胞密度指标的诊断效能。外周带ADC参数(尤其ADCmean)与Gleason评分相关性更好、鉴别GS 6与GS≥7的AUC更高;移行带所有参数与Gleason评分及细胞密度指标相关性均差。
要点
- 外周带病灶中ADC参数与Gleason评分相关性优于T2参数,ADCmean鉴别GS 6与GS≥7的AUC最高。
- 移行带病灶中所有mpMRI参数与Gleason评分及细胞密度指标相关性均差。
- ADCmean与外周带病灶核质比及核分数呈中等相关。
核心结论
- mpMRI可有效检出指数病灶与临床显著性前列腺癌病灶。
- 外周带病灶中ADC参数(尤其ADCmean)与Gleason评分及细胞密度指标的相关性优于T2参数;移行带病灶中所有参数表现均差。
研究设计与样本
- 回顾性纳入225例前列腺癌患者,均有术前mpMRI及全mount病理切片。
- 共识别398个病灶,评估指数病灶(最高GS或最大径)与临床显著性前列腺癌的检出率。
- 衍生肿瘤-肌肉比值、T2信号强度偏度、平均ADC(ADCmean)及第10百分位ADC(ADC10%),以Spearman相关系数ρ分析其与GS的相关性,以ROC分析比较鉴别GS 6与GS≥7的效能,以Pearson相关系数r评估细胞密度指标与mpMRI参数的相关性。
诊断标准与关键数值
- 共识别398个病灶,指数病灶检出率87.1%(196/225),临床显著性前列腺癌检出率86.8%(249/287)。
- 外周带病灶中ADC参数与GS相关性优于T2参数(最大ρ:-0.58 vs -0.33,p=0.011)。
- 外周带病灶中ADC参数鉴别GS 6与GS≥7的AUC高于T2参数(最大AUC:0.854 vs 0.731,p=0.020)。
- ADCmean与核质比及核分数呈中等相关(r=-0.403和-0.514,p<0.001)。
- 移行带病灶中所有参数与GS及细胞密度指标相关性均差。
临床应用与阅片要点
- 阅片时可关注外周带病灶的ADCmean,其与Gleason评分及细胞密度指标相关性相对较好。
- 移行带病灶中mpMRI参数与Gleason评分及细胞密度指标相关性均差,判读时需谨慎。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To compare the diagnostic performance of multiparametric MRI (mpMRI) parameters for Gleason score (GS) and cellularity metrics of prostate cancer (PCa) in the peripheral zone (PZ) and transition zone (TZ) separately.
MATERIALS AND METHODS: In total, 225 PCa patients with preoperative mpMRI and whole-mount pathological sections were enrolled retrospectively. Detection rates of index lesions (highest GS or largest dimension) and clinically significant PCa (csPCa) were evaluated. Tumour-to-muscle ratio and skewness of T2 signal intensity, average apparent diffusion coefficient (ADCmean) and 10th percentile ADC (ADC10%) were derived and correlation with GS was performed with Spearman's correlation coefficient (ρ), while effectiveness in differentiating GS 6 from GS ≥7 was compared with receiver operating characteristic (ROC) analysis. Moreover, correlation of cellularity metrics with mpMRI parameters was evaluated with Pearson's correlation coefficient (r).
RESULTS: In total, 398 lesions were identified, with 87.1% (196/225) index lesions and 86.8% (249/287) csPCa detected. Compared to T2 parameters, ADC parameters, especially ADCmean, correlated better with GS (maximal ρ: -0.58 versus -0.33, p=0.011) and yielded significantly higher area under the curve (AUC) in differentiating GS 6 from GS ≥7 (maximal AUC: 0.854 versus 0.731, p=0.020) among PZ lesions. Moreover, ADCmean demonstrated significantly moderate correlation with the nuclear-to-cytoplasmic ratio and nuclear fraction (r=-0.403 and -0.514, p<0.001); however, for TZ lesions, all parameters demonstrated poor correlation with GS and cellularity metrics.
CONCLUSION: mpMRI could effectively detect index and csPCa lesions. ADC parameters, especially ADCmean, correlated better with GS and cellularity metrics than T2 in PZ, while all parameters demonstrated poor performance within TZ lesions.
引用
- Gao J, Zhang Q, Zhang C, et al. Diagnostic performance of multiparametric MRI parameters for Gleason score and cellularity metrics of prostate cancer in different zones: a quantitative comparison. Clin Radiol. 2019. PMID: 31337490. doi:10.1016/j.crad.2019.06.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。