文献速递泌尿生殖US

弹性成像Q分析评分在辅助实时弹性成像引导前列腺穿刺活检中的临床价值:125例患者回顾性研究

Clinical Value of the Elastographic Q-Analysis Score in Assisting Real-Time Elastography-Guided Prostate Biopsy: A Retrospective Study of 125 Patients.
PubMed 文献 · J Ultrasound Med · 2019-07-01

回顾性纳入125例患者共301个病灶,穿刺前行经直肠超声及弹性成像检查,用Q分析软件测量平均弹性成像Q分析评分(EQS),病灶均经病理证实;良性病灶平均EQS为1.47±0.75,恶性为2.98±1.06,差异有统计学意义(P<.05),AUC为0.87, cutoff值1.95时敏感度83.5%、特异度84.4%。结论认为EQS可用于预测病灶良恶性,从而指导追加靶向穿刺。

要点

  • 良性病灶平均EQS为1.47±0.75,恶性病灶为2.98±1.06,差异有统计学意义(P<.05)。
  • EQS预测前列腺癌的AUC为0.87,cutoff值1.95时敏感度83.5%、特异度84.4%。
  • cutoff值1.95时阳性预测值76.8%、阴性预测值89.2%,阳性似然比5.35、阴性似然比0.20。

核心结论

  • EQS可用于预测病灶良恶性,从而指导追加靶向穿刺。

研究设计与样本

  • 回顾性研究纳入125例患者共301个病灶,所有病灶均经病理结果证实;穿刺前均行经直肠超声及弹性成像检查,使用弹性成像Q分析软件测量弹性图像的平均EQS;先对弹性成像可疑区域穿刺,再行12针系统前列腺穿刺;采用EQS曲线计算平均EQS,并绘制受试者工作特征曲线确定预测前列腺癌的cutoff值。

诊断标准与关键数值

  • 以EQS 1.95为鉴别良恶性病灶的cutoff值时,敏感度83.5%、特异度84.4%、阳性预测值76.8%、阴性预测值89.2%、阳性似然比5.35、阴性似然比0.20;AUC为0.87。

临床应用与阅片要点

  • 原文结论认为EQS可作为预测病灶良恶性的方法,并据此指导追加靶向穿刺。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to evaluate the clinical value of the elastographic Q-analysis score (EQS) in assisting real-time elastography- and transrectal US-guided prostate biopsy.

METHODS: A total of 125 patients with 301 lesions were enrolled in this study; all were confirmed by pathologic results. The patients underwent transrectal US and elastographic examinations before biopsy. Elastographic Q-analysis score analysis software was used for measuring the mean EQS of the elastic images. First, the suspicious regions on elastography underwent biopsy. Then 12-core systematic prostate biopsy was performed. An EQS curve was used to calculate the mean EQS, and a receiver operating characteristic curve was drawn to find the cutoff point for the EQS to predict prostate cancer.

RESULTS: Of the 301 lesions in this study, 125 were malignant, and 176 were benign. The mean EQS values of benign and malignant lesions ± SD were 1.47 ± 0.75 and 2.98 ± 1.06, respectively. The difference was statistically significant (P < .05). The area under the receiver operating characteristic curve was 0.87. When the cutoff point was 1.95 for diagnosing malignant and benign lesions, the sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio were 83.5%, 84.4%, 76.8%, 89.2%, 5.35, and 0.20.

CONCLUSIONS: The EQS could be used as a way to predict benign and malignant lesions and thus could serve as guidance for adding targeted biopsy.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Ding Z, Jiao Y, Wu H, et al. Clinical Value of the Elastographic Q-Analysis Score in Assisting Real-Time Elastography-Guided Prostate Biopsy: A Retrospective Study of 125 Patients. J Ultrasound Med. 2019. PMID: 31264233. doi:10.1002/jum.15075

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。