文献速递儿科影像泌尿生殖技术与安全US

超声诊断儿童睾丸扭转中睾丸旋转方向及精索扭转程度的诊断准确性

Diagnostic Accuracy of Ultrasound for the Directionality of Testicular Rotation and the Degree of Spermatic Cord Twist in Pediatric Patients With Testicular Torsion.
PubMed 文献 · J Ultrasound Med · 2019-07-03

回顾性分析14例儿童睾丸扭转患者,评估超声判断睾丸旋转方向及精索扭转程度的诊断准确性。超声判断旋转方向的准确率为78.6%(11/14,95%CI 49.2%-95.3%),判断精索扭转程度的准确率为36.4%(4/11,95%CI 10.9%-69.2%)。超声测得的精索扭转程度与手术结果无显著差异(343.0°±97.1° vs 458.2°±168.2°,P=.063),作者认为超声判断旋转方向的信息可能有助于早期手法复位。

要点

  • 超声判断儿童睾丸扭转旋转方向的准确率为78.6%(11/14),判断精索扭转程度的准确率仅36.4%(4/11)。
  • 超声测得的精索扭转程度与手术结果无显著差异(343.0°±97.1° vs 458.2°±168.2°,P=.063)。
  • 睾丸 salvage 组与睾丸丢失组间,超声判断的旋转方向及扭转程度无显著差异(P=.627;P>.999)。

核心结论

  • 在小样本队列中,超声判断睾丸旋转方向的准确性相对较高,该信息可能有助于小儿外科和泌尿外科医生进行早期手法复位。

研究设计与样本

  • 回顾性研究,纳入14例儿童睾丸扭转患者,评估超声诊断睾丸旋转方向及精索扭转程度的准确性;统计方法包括Clopper-Pearson法、Fisher精确检验、Mann-Whitney U检验和Wilcoxon符号秩和检验。

诊断标准与关键数值

  • 超声诊断睾丸旋转方向的准确率为78.6%(11/14;95%CI 49.2%-95.3%)。
  • 超声诊断精索扭转程度的准确率为36.4%(4/11;95%CI 10.9%-69.2%)。
  • 旋转方向定义:内方向为左侧睾丸逆时针(从下方观察)、右侧睾丸顺时针;外方向为右侧睾丸逆时针、左侧睾丸顺时针。
  • 外方向旋转占50.0%。

临床应用与阅片要点

  • 作者认为超声判断的睾丸旋转方向信息可能有助于小儿外科和泌尿外科医生进行早期手法复位。
  • 睾丸 salvage 组与睾丸丢失组间,超声判断的旋转方向(内/外:4/2 vs 4/4,P=.627)及精索扭转程度(330.0°±73.5° vs 337.5°±115.4°,P>.999)均无显著差异。
  • 超声测得的精索扭转程度与手术结果无显著差异(343.0°±97.1° vs 458.2°±168.2°,P=.063)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the diagnostic accuracy of ultrasound (US) to diagnose the directionality of testicular rotation and the degree of spermatic cord twist in pediatric patients with testicular torsion.

METHODS: A retrospective review of 14 pediatric patients with testicular torsion was conducted. The directionality of testicular rotation was classified as an inner or outer direction (inner, counterclockwise in the left testis [viewed from below] and clockwise in the right testis; and outer, counterclockwise in the right testis and clockwise in the left testis). The Clopper-Pearson method and the Fisher exact, Mann-Whitney U, and Wilcoxon signed rank sum tests were used for the statistical analyses.

RESULTS: The diagnostic accuracy of US in the directionality of testicular rotation and the degree of spermatic cord twist were 78.6% (11 of 14; 95% confidence interval, 49.2%-95.3%) and 36.4% (4 of 11; 95% confidence interval, 10.9%-69.2%), respectively. Outer rotation was seen in 50.0% of the cases. The directionality of testicular rotation and the degree of spermatic cord twist as determined by US were not significantly different between the patients with salvaged testis and those with testicular loss (inner/outer direction, 4/2 versus 4/4; P = .627; mean twist ± SD, 330.0° ± 73.5° versus 337.5° ± 115.4°; P > .999). There was no significant difference in the degree of spermatic cord twist determined by US and surgical results (343.0° ± 97.1° versus 458.2° ± 168.2°; P = .063).

CONCLUSIONS: The accuracy of US in determining the directionality of testicular rotation was relatively high in our small cohort. This information may be useful for pediatric surgeons and urologists when performing early manual reduction for testicular torsion.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Hosokawa T, Takahashi H, Tanami Y, et al. Diagnostic Accuracy of Ultrasound for the Directionality of Testicular Rotation and the Degree of Spermatic Cord Twist in Pediatric Patients With Testicular Torsion. J Ultrasound Med. 2019. PMID: 31268182. doi:10.1002/jum.15084

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。