文献速递泌尿生殖介入DSA

机器人辅助肾部分切除术中经肾动脉球囊导管低温灌注的应用及其对肾功能的影响

Application of Hypothermic Perfusion via a Renal Artery Balloon Catheter During Robot-assisted Partial Nephrectomy and Effect on Renal Function.
PubMed 文献 · Acad Radiol · 2018-10-27

本研究纳入2013年3月至2017年8月的43例肾肿瘤患者,在血管造影引导下置入肾动脉球囊导管并完全充盈阻断肾动脉,经导管以4°C乳酸钠林格液灌注后行机器人辅助肾部分切除术(h-RAPN),用肾动态显像以单位体积肾小球滤过率(GFR-UV)评估肾功能。结果显示6例中转根治性肾切除术,37例成功完成h-RAPN,无严重并发症;患肾术后平均GFR-UV为0.42±0.09 ml/min/ml,健肾为0.30±0.04 ml/min/ml(P>0.05),冷缺血时间是影响患肾术后GFR的独立危险因素。作者认为h-RAPN可获得清晰术野、实现精准切除,联合球囊导管低温灌注可在延长手术时间的同时不增加患肾功能损害,是治疗肾肿瘤安全有效的方法。

要点

  • 患肾术后平均GFR-UV为0.42±0.09 ml/min/ml,健肾为0.30±0.04 ml/min/ml(P>0.05),两者无显著差异。
  • 平均冷缺血时间为39.5±9.7 min(范围22-123 min),术中患肾平均温度为19.3±3.5°C(17.2-26.7°C)。
  • 多因素回归分析显示冷缺血时间是影响患肾术后GFR的独立危险因素。

核心结论

  • 作者认为h-RAPN术野清晰、可精准切除,联合经肾动脉球囊导管低温灌注可在延长手术时间的同时不增加患肾功能损害,是治疗肾肿瘤安全有效的方法。

研究设计与样本

  • 单臂研究,纳入2013年3月至2017年8月的43例肾肿瘤患者,在血管造影引导下置入肾动脉球囊导管,建立静脉流出口后经导管以4°C乳酸钠林格液灌注并行机器人辅助肾部分切除术,用肾动态显像以GFR-UV为计算单位评估肾功能。

诊断标准与关键数值

  • 肾功能以肾动态显像的单位体积肾小球滤过率(GFR-UV)评估,患肾术后平均0.42±0.09 ml/min/ml(0.21-1.24 ml/min),健肾术后平均0.30±0.04 ml/min/ml(P>0.05)。
  • 术中患肾平均温度19.3±3.5°C(17.2-26.7°C),平均冷缺血时间39.5±9.7 min(范围22-123 min)。
  • 多因素回归分析显示冷缺血时间是影响患肾术后GFR的独立危险因素。

临床应用与阅片要点

  • 6例术中中转根治性肾切除术,余37例成功完成h-RAPN。
  • 2例肾动脉阻断不全,术中补充行动脉夹阻断。
  • 1例球囊导管术前移位,返回介入放射科重新置入后手术成功。
  • 无患者发生严重并发症。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE OBJECTIVES: To assess the feasibility, safety, and effect of hypothermic perfusion on postoperative renal function employing a renal artery balloon catheter inserted via robot-assisted partial nephrectomy (h-RAPN) to treat renal tumors.

MATERIALS AND METHODS: Forty-three patients with renal tumors were studied between March 2013 and August 2017. Renal artery balloon catheters were placed under angiographic guidance, and the balloon was fully inflated to occlude the renal artery during surgery. After establishing venous outflow, a robot-assisted partial nephrectomy was performed following perfusion with sodium lactate Ringer's solution at 4°C through the balloon catheter. Renal dynamic imaging was used to assess renal function, with calculation units consisting of glomerular filtration rate per unit volume of the kidney (GFR-UV).

RESULTS: Six patients were converted to radical nephrectomy intraoperatively, and the remaining 37 patients successfully underwent the h-RAPN procedure. Two patients had incomplete occlusion of the renal artery and received supplementary arterial clamp occlusion intraoperatively. One patient's balloon catheter slipped out of position preoperatively, and the patient was returned to the interventional radiology suite for balloon reinsertion, after which the patient underwent surgery successfully. No patients had severe complications. The average cold ischemia time was 39.5 ± 9.7 min (range, 22-123 min), the average temperature of the affected kidney during surgery was 19.3 ± 3.5°C (17.2-26.7°C), the average postoperative GFR-UV of the affected kidney was 0.42 ± 0.09 ml/min/ml (0.21-1.24 ml/min), and the average postoperative GFR-UV of the healthy kidney was 0.30 ± 0.04 ml/min/ml (P > 0.05). Multiple regression analysis indicated that cold ischemia time was an independent risk factor affecting the postoperative GFR of the affected kidney.

CONCLUSION: The advantages of h-RAPN include a clear surgical field enabling precise resection. When hypothermic perfusion via a renal artery balloon catheter is performed in conjunction with h-RAPN, the surgical time can be lengthened without increasing impairment of the affected kidney function, making this a safe and effective method of treating kidney tumors.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Liu F, Yuan H, Li X, et al. Application of Hypothermic Perfusion via a Renal Artery Balloon Catheter During Robot-assisted Partial Nephrectomy and Effect on Renal Function. Acad Radiol. 2018. PMID: 31284936. doi:10.1016/j.acra.2018.09.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。