超声时谐弹性成像用于肾小球肾炎的早期检测
该前瞻性研究纳入53例活检证实的肾小球肾炎患者和30名健康志愿者,采用超声时谐弹性成像测量肾剪切波速度。肾小球肾炎患者年龄校正后的肾实质、皮质及髓质剪切波速度均低于健康志愿者,且早期CKD(肾功能保留)患者皮质剪切波速度已降低;弹性成像鉴别肾小球肾炎的AUC为0.89,优于肾实质厚度(AUC 0.64)和肾长度(AUC 0.55)。
要点
- 肾小球肾炎患者肾皮质剪切波速度低于健康志愿者,早期CKD即可出现。
- 年龄校正后肾皮质剪切波速度与eGFR呈正相关(r=0.56)。
- 弹性成像鉴别肾小球肾炎的AUC为0.89,优于B-mode参数。
核心结论
- 超声时谐弹性成像可显示肾小球肾炎患者的肾脏硬度异常,尤其在早期疾病且肾功能保留的患者中。
- 晚期慢性肾脏病与进一步的皮质软化相关。
- 时谐弹性成像优于基于B-mode的大小量化。
研究设计与样本
- 研究为前瞻性研究,2016年8月至2017年5月纳入经活检证实的肾小球肾炎患者53例(平均年龄49岁±14)和健康志愿者30名(平均年龄37岁±11)。
- 所有参与者均行双肾超声时谐弹性成像,生成全视野肾剪切波速度图,分别测定全肾实质、皮质和髓质的剪切波速度。
- 以活检为参考标准,采用受试者工作特征曲线分析评估诊断性能。
关键影像表现/征象
- 肾小球肾炎患者年龄校正后的肾实质剪切波速度为1.55 m/sec(95%CI:1.51 m/sec,1.59 m/sec),低于健康志愿者的1.69 m/sec(95%CI:1.64 m/sec,1.74 m/sec;P < .001)。
- 肾小球肾炎患者年龄校正后的肾皮质剪切波速度为1.80 m/sec(95%CI:1.75 m/sec,1.84 m/sec),低于健康志愿者的2.08 m/sec(95%CI:2.02 m/sec,2.13 m/sec;P < .001)。
- 肾小球肾炎患者年龄校正后的肾髓质剪切波速度为1.25 m/sec(95%CI:1.21 m/sec,1.29 m/sec),低于健康志愿者的1.33 m/sec(95%CI:1.27 m/sec,1.38 m/sec;P = .03)。
诊断标准与关键数值
- 肾小球肾炎合并1期CKD(肾功能保留)患者年龄校正后的肾皮质剪切波速度为1.88 m/sec(95%CI:1.81,1.96),低于健康志愿者的2.08 m/sec(95%CI:2.02,2.13;P < .001)。
- 在CKD患者中,肾皮质剪切波速度与估算肾小球滤过率呈正相关(n = 39;r = 0.56;P < .001)。
- 超声时谐弹性成像鉴别肾小球肾炎的探索性诊断性能AUC为0.89(95%CI:0.82,0.97),优于肾实质厚度(AUC 0.64;95%CI:0.51,0.77;P < .001)和肾长度(AUC 0.55;95%CI:0.40,0.68;P < .001)。
临床应用与阅片要点
- 阅片时关注肾皮质剪切波速度降低,早期CKD患者即可出现。
- 肾皮质剪切波速度与eGFR正相关,可辅助评估肾功能损伤程度。
- 弹性成像诊断性能优于B-mode肾实质厚度和肾长度测量。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Glomerulonephritis refers to renal diseases characterized by glomerular and tubulointerstitial fibrosis. Multifrequency US time-harmonic elastography enables the noninvasive quantification of tissue elasticity. Purpose To assess the diagnostic performance of US time-harmonic elastography for the early detection of glomerulonephritis. Materials and Methods From August 2016 through May 2017, study participants with biopsy-proven glomerulonephritis were prospectively examined with US time-harmonic elastography. Participants were subdivided according to chronic kidney disease (CKD) stage. All participants underwent elastography of both kidneys to generate full-field-of-view maps of renal shear wave speed (SWS). SWS was determined separately for the whole renal parenchyma, cortex, and medulla and was correlated with quantitative B-mode findings such as renal length and parenchymal thickness. Diagnostic performance of renal elastography was assessed with receiver operating characteristic curve analysis. Results Fifty-three participants with glomerulonephritis (mean age ± standard deviation, 49 years ± 14) and 30 healthy volunteers (mean age, 37 years ± 11) were evaluated. Age-adjusted renal SWS was lower in participants with glomerulonephritis than in healthy volunteers in the parenchyma, cortex, and medulla, with mean values of 1.55 m/sec (95% confidence interval [CI]: 1.51 m/sec, 1.59 m/sec) and 1.69 m/sec (95% CI: 1.64 m/sec, 1.74 m/sec; P < .001), respectively, in parenchyma, 1.80 m/sec (95% CI: 1.75 m/sec, 1.84 m/sec) and 2.08 m/sec (95% CI: 2.02 m/sec, 2.13 m/sec; P < .001) in cortex, and 1.25 m/sec (95% CI: 1.21 m/sec, 1.29 m/sec) and 1.33 (95% CI: 1.27 m/sec, 1.38 m/sec; P = .03) in medulla. Age-adjusted renal cortex SWS was lower in participants with glomerulonephritis and stage 1 CKD (preserved renal function) than in healthy volunteers (mean, 1.88 [95% CI: 1.81, 1.96] vs 2.08 [95% CI: 2.02, 2.13]; P < .001). In participants with CKD, renal cortex SWS values showed a positive association with estimated glomerular filtration rate (n = 39; r = 0.56; P < .001). Exploratory diagnostic performance of US time-harmonic elastography (area under the receiver operating characteristic curve [AUC], 0.89; 95% CI: 0.82, 0.97) outperformed that of B-mode parameters such as parenchymal thickness (AUC, 0.64; 95% CI: 0.51, 0.77; P < .001) and renal length (AUC, 0.55; 95% CI: 0.40, 0.68; P < .001) in identifying glomerulonephritis. Conclusion US time-harmonic elastography depicts abnormal renal stiffness in glomerulonephritis, particularly among patients with early disease and preserved renal function. Advanced chronic kidney disease is associated with further cortical softening. Time-harmonic elastography outperforms B-mode-based size quantification. © RSNA, 2019 Online supplemental material is available for this article.
引用
- Grossmann M, Tzschätzsch H, Lang ST, et al. US Time-Harmonic Elastography for the Early Detection of Glomerulonephritis. Radiology. 2019. PMID: 31287390. doi:10.1148/radiol.2019182574
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。