文献速递腹部泌尿生殖MR

猪肾急性分级缺血模型中磁化传递成像不受肾灌注下降影响

Magnetization Transfer Imaging Is Unaffected by Decreases in Renal Perfusion in Swine.
PubMed 文献 · Invest Radiol · 2019-01-01

研究在7只猪肾动脉狭窄模型中行多参数MRI,发现分级缺血时灌注下降伴R2*升高、ADC和硬度降低,但磁化传递率(MTR)无统计学显著变化;组织学未检出纤维化,提示MTI对肾灌注变化不敏感,可能可靠评估肾结构改变。

要点

  • 肾分级缺血时MTR无统计学显著变化,而R2*、ADC和硬度随灌注改变而变化。
  • 再灌注后肾灌注仅部分恢复,皮质MTR轻度下降,R2*、ADC和硬度回到基线。
  • 组织学未检出纤维化,提示MTR变化并非来自纤维化。

核心结论

  • 肾MTI对肾灌注下降不敏感,可能为肾结构改变提供可靠评估。

研究设计与样本

  • 研究论文,7只家猪右肾动脉置入可充气硅胶袖带诱导分级缺血,在基线、50%、75%、100%肾动脉狭窄及再灌注时行多参数MRI,并行组织学检查排除肾纤维化。

关键影像表现/征象

  • 分级缺血期间肾灌注下降,伴R2*升高、ADC降低和硬度降低,而MTR无统计学显著变化。
  • 解除梗阻后肾灌注仅部分恢复,R2*、ADC和硬度回到基线水平,皮质MTR轻度下降。
  • 组织学未检出纤维化。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Multiparametric renal magnetic resonance imaging (MRI), including diffusion-weighted imaging, magnetic resonance elastography, and magnetization transfer imaging (MTI), is valuable in the noninvasive assessment of renal fibrosis. However, hemodynamic changes in diseased kidneys may impede their ability to measure renal fibrosis. Because MTI assesses directly tissue content of macromolecules, we test the hypothesis that MTI would be insensitive to renal hemodynamic changes in swine kidneys with acute graded ischemia.

MATERIALS AND METHODS: Seven domestic pigs underwent placement of an inflatable silicone cuff around the right renal artery to induce graded renal ischemia. Multiparametric MRI was performed at baseline, 50%, 75%, and 100% renal artery stenosis as well as reperfusion. Measurements included regional perfusion, R2*, apparent diffusion coefficient (ADC), stiffness, and magnetization transfer ratio (MTR) using arterial spin-labeled MRI, blood oxygenation-dependent MRI, diffusion-weighted imaging, magnetic resonance elastography, and MTI, respectively. Histology was performed to rule out renal fibrosis.

RESULTS: During graded ischemia, decreases in renal perfusion were accompanied with elevated R2*, decreased ADC, and stiffness, whereas no statistically significant changes were observed in the MTR. No fibrosis was detected by histology. After release of the obstruction, renal perfusion showed only partial recovery, associated with return of kidney R2*, ADC, and stiffness to baseline levels, whereas cortical MTR decreased slightly.

CONCLUSIONS: Renal MTI is insensitive to decreases in renal perfusion and may offer reliable assessment of renal structural changes.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Jiang K, Ferguson CM, Woollard JR, et al. Magnetization Transfer Imaging Is Unaffected by Decreases in Renal Perfusion in Swine. Invest Radiol. 2019. PMID: 31261296. doi:10.1097/RLI.0000000000000588

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。