基于时间分辨定量双能CT碘图的动态CT灌注测量:与80 kVp常规灌注在胰腺癌中的比较

Measuring Dynamic CT Perfusion Based on Time-Resolved Quantitative DECT Iodine Maps: Comparison to Conventional Perfusion at 80 kVp for Pancreatic Carcinoma.
PubMed 文献 · Invest Radiol · 2019-01-01

本研究在17例胰腺癌患者中,用80/Sn140 kVp动态DECT采集51秒,经三物质分解生成碘增强图,并以最大斜率模型计算血流量图,与80 kVp图像数据对比。结果显示两种图均显示健康胰腺组织血流量显著高于癌组织;碘增强图对残余呼吸运动敏感性更低,但动态DECT辐射剂量更高。

要点

  • 碘增强图在胰腺周围脂肪组织测得的血流量显著低于80 kVp图,提示对残余呼吸运动敏感性降低。
  • 动态DECT平均辐射剂量8.01 mSv,高于动态80 kVp的4.60 mSv。

核心结论

  • 碘增强图可用于计算血流量CT灌注图,与80 kVp图像相比健康组织血流量仅差约1 mL/100 mL/min,但动态DECT辐射剂量增加。
  • 基于碘增强图的灌注图在胰腺周围脂肪组织显示更低血流量,提示对采集期间残余呼吸运动的敏感性降低。

研究设计与样本

  • 研究论文,17例胰腺癌患者,行80/Sn140 kVp动态DECT采集51秒,经三物质分解生成各时间点碘增强图。
  • 运动校正后,分别从80 kVp图像数据和碘增强图以最大斜率模型计算血流量灌注图。
  • 在健康胰腺组织和癌组织的感兴趣区内测量血流量,并计算调整对比噪声比评估输入图像质量。
  • 通过测量胰腺周围脂肪组织血流量评估灌注结果对残余呼吸运动的敏感性。

关键影像表现/征象

  • 健康胰腺组织血流量在80 kVp图为114.2 ± 37.4 mL/100 mL/min,在碘增强图为115.1 ± 36.2 mL/100 mL/min。
  • 癌组织血流量在80 kVp图为46.5 ± 26.6 mL/100 mL/min,在碘增强图为49.7 ± 24.7 mL/100 mL/min。
  • 健康组织血流量在80 kVp图与碘增强图间差异有统计学意义,癌组织间差异无统计学意义。
  • 胰腺周围脂肪组织血流量在碘增强图为30.7 ± 12.0 mL/100 mL/min,显著低于80 kVp图的39.0 ± 19.1 mL/100 mL/min。

诊断标准与关键数值

  • 80 kVp图调整对比噪声比为1.3 ± 1.1,显著高于碘增强图的1.1 ± 0.9。
  • 灌注计算采用最大斜率模型,血流量单位为mL/100 mL/min。

临床应用与阅片要点

  • 阅片时注意碘增强图灌注在癌组织与80 kVp图差异无统计学意义,但健康组织存在统计学显著差异。
  • 胰腺周围脂肪组织血流量在碘增强图更低,判读时需考虑残余呼吸运动对灌注值的影响。
  • 动态DECT辐射剂量8.01 mSv高于动态80 kVp的4.60 mSv,临床应用需权衡剂量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Using dual-energy computed tomography (DECT) for quantifying iodine content after injection of contrast agent could provide a quantitative basis for dynamic computed tomography (CT) perfusion measurements by means of established mathematical models of contrast agent kinetics, thus improving results by combining the strength of both techniques, which was investigated in this study.

MATERIALS AND METHODS: A dynamic DECT acquisition over 51 seconds performed at 80/Sn140 kVp in 17 patients with pancreatic carcinoma was used to calculate iodine-enhancement images for each time point by means of 3-material decomposition. After motion correction, perfusion maps of blood flow were calculated using the maximum-slope model from both 80 kVp image data and iodine-enhancement images. Blood flow was measured in regions of interest placed in healthy pancreatic tissue and carcinoma for both of the derived perfusion maps. To assess image quality of input data, an adjusted contrast-to-noise ratio was calculated for 80 kVp images and iodine-enhancement images. Susceptibility of perfusion results to residual patient breathing motion during acquisition was investigated by measuring blood flow in fatty tissue surrounding the pancreas, where blood flow should be negligible compared with the pancreas.

RESULTS: For both 80 kVp and iodine-enhancement images, blood flow was significantly higher in healthy tissue (114.2 ± 37.4 mL/100 mL/min or 115.1 ± 36.2 mL/100 mL/min, respectively) than in carcinoma (46.5 ± 26.6 mL/100 mL/min or 49.7 ± 24.7 mL/100 mL/min, respectively). Differences in blood flow between 80 kVp image data and iodine-enhancement images were statistically significant in healthy tissue, but not in carcinoma. For 80 kVp images, adjusted contrast-to-noise ratio was significantly higher (1.3 ± 1.1) than for iodine-enhancement images (1.1 ± 0.9). When evaluating fatty tissue surrounding the pancreas for estimating influence of patient motion, measured blood flow was significantly lower for iodine-enhancement images (30.7 ± 12.0 mL/100 mL/min) than for 80 kVp images (39.0 ± 19.1 mL/100 mL/min). Average patient radiation exposure was 8.01 mSv for dynamic DECT acquisition, compared with 4.60 mSv for dynamic 80 kVp acquisition.

DISCUSSION: Iodine enhancement images can be used to calculate CT perfusion maps of blood flow, and compared with 80 kVp images, results showed only a small difference of 1 mL/100 mL/min in blood flow in healthy tissue, whereas patient radiation exposure was increased for dynamic DECT. Perfusion maps calculated based on iodine-enhancement images showed lower blood flow in fatty tissues surrounding the pancreas, indicating reduced susceptibility to residual patient breathing motion during the acquisition.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Skornitzke S, Kauczor HU, Stiller W, et al. Measuring Dynamic CT Perfusion Based on Time-Resolved Quantitative DECT Iodine Maps: Comparison to Conventional Perfusion at 80 kVp for Pancreatic Carcinoma. Invest Radiol. 2019. PMID: 31335633. doi:10.1097/RLI.0000000000000591

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。