文献速递外周血管技术与安全US

血容量变化对健康志愿者下腔静脉与主动脉直径及腔静脉/主动脉指数的影响

Effect of Changes in Intravascular Volume on Inferior Vena Cava and Aorta Diameters and the Caval/Aorta Index in Healthy Volunteers.
PubMed 文献 · J Ultrasound Med · 2019-07-08

前瞻性观察研究在献血中心纳入39名健康志愿者,献血500 mL前后及0.9%氯化钠500 mL复苏后行超声测量下腔静脉直径、腹主动脉直径及腔静脉/主动脉指数。献血后休克指数、下腔静脉直径和腔静脉/主动脉指数百分比变化相似且均高于脉搏、腹主动脉直径和血压变化;复苏后下腔静脉直径和休克指数显著变化而腔静脉/主动脉指数无显著变化。作者认为三者诊断早期失血成功率可能相似,需同时液体复苏时休克指数和下腔静脉直径可能优于腔静脉/主动脉指数。

要点

  • 献血500 mL后下腔静脉直径、休克指数和腔静脉/主动脉指数百分比变化相似,均高于腹主动脉直径变化。
  • 液体复苏后下腔静脉直径和休克指数显著变化,腔静脉/主动脉指数无显著变化(P = .059)。
  • 需同时液体复苏的出血患者中,休克指数和下腔静脉直径可能优于腔静脉/主动脉指数。

核心结论

  • 腔静脉/主动脉指数、休克指数和下腔静脉直径诊断早期失血的成功率可能相似。
  • 在需要同时液体复苏的出血患者中,休克指数和下腔静脉直径可能优于腔静脉/主动脉指数。

研究设计与样本

  • 前瞻性观察研究,在培训与研究医院的献血中心进行,遵循标准献血标准招募志愿者。
  • 共纳入39名健康志愿者,献血前后及500 mL 0.9%氯化钠液体复苏后测量生命体征和超声下腔静脉直径、腹主动脉直径。
  • 采用配对t检验和Wilcoxon配对检验比较献血前后及液体复苏后的测量值。

诊断标准与关键数值

  • 献血500 mL后休克指数百分比变化为7% ± 6%,下腔静脉直径为6% ± 2%,腔静脉/主动脉指数为6.1% ± 3%,三者相似且均高于脉搏(3% ± 4%)、腹主动脉直径(0.5% ± 1.5%)、收缩压(3% ± 4%)和舒张压(2% ± 7%)的变化(所有参数P < .001)。
  • 500 mL 0.9%氯化钠复苏后下腔静脉直径和休克指数均显著变化(P < .001),腔静脉/主动脉指数无显著变化(P = .059)。

临床应用与阅片要点

  • 超声测量下腔静脉直径可用于无创监测容量状态,联合腹主动脉直径计算腔静脉/主动脉指数在早期失血诊断中可能有用。
  • 在需要同时液体复苏的出血患者中,作者认为休克指数和下腔静脉直径可能优于腔静脉/主动脉指数。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Although inferior vena cava diameter (IVCD) measurement can be useful as a noninvasive method for monitoring the volume status, the benefit of abdominal aorta diameter (AAD) measurement is unclear. The purpose of this study was to determine the value of the combined use of the IVCD and AAD in blood loss monitoring.

METHODS: This prospective observational study was conducted at the blood donor center of a training and research hospital. Standard blood donation criteria were followed during volunteer enrollment. Vital signs and ultrasound IVCD and AAD measurements were obtained before and after blood donation and after fluid resuscitation with 500 mL of 0.9% sodium chloride. Measurements before and after blood donation and after fluid resuscitation were compared by the paired t and Wilcoxon matched-pair tests.

RESULTS: Thirty-nine volunteers were included in the study. With 500 mL of blood loss, percent changes in the shock index (SI; mean ± SD, 7% ± 6%), IVCD (6% ± 2%), and caval/aorta index (IVCD/AAD; 6.1% ± 3%) were similar and were higher (P < .001 for all parameters) than the changes in the pulse rate (3% ± 4%), AAD (0.5% ± 1.5%), systolic blood pressure (3% ± 4%), and diastolic blood pressure (2% ± 7%). Although IVCD and SI values changed significantly (P < .001 for both) after 500 mL of 0.9% sodium chloride resuscitation, no significant change was observed in the IVCD/AAD (P = .059).

CONCLUSIONS: The IVCD/AAD, SI, and IVCD may have similar success rates in diagnosing early blood loss. Additionally, the SI and IVCD may be superior to the IVCD/AAD in bleeding patients requiring simultaneous fluid resuscitation.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Bilgin S, Topal FE, Yamanoğlu A, et al. Effect of Changes in Intravascular Volume on Inferior Vena Cava and Aorta Diameters and the Caval/Aorta Index in Healthy Volunteers. J Ultrasound Med. 2019. PMID: 31283047. doi:10.1002/jum.15093

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。