双层光谱CT改善胰腺导管腺癌患者多期胰腺CT的图像质量
本研究纳入48例胰腺导管腺癌患者,在胰腺实质期和门静脉期行双层光谱探测器CT增强扫描,重建常规多能图像及40-100 keV虚拟单能图像。结果显示低keV虚拟单能图像客观与主观图像质量均优于常规多能图像,门静脉期低keV图像肿瘤显示度和动脉显示可媲美常规胰腺实质期图像。
要点
- 双层光谱CT虚拟单能图像在40 keV时图像噪声最低、胰腺与肿瘤对比噪声比及主观评分最高。
- 门静脉期40-50 keV虚拟单能图像肿瘤显示度与动脉/静脉显示等同或优于常规胰腺实质期多能图像。
- 各期之间体型特异性剂量估算值无显著差异,低keV虚拟单能图像未增加辐射剂量。
核心结论
- 双层光谱CT虚拟单能图像可改善胰腺导管腺癌多期胰腺CT的主观与客观图像质量;门静脉期低keV图像可能提供诊断足够的肿瘤显示度和动脉评估,与常规胰腺实质期多能图像相当。
研究设计与样本
- 研究纳入48例胰腺导管腺癌患者,在胰腺实质期和门静脉期行双层光谱探测器CT增强扫描,重建常规多能图像及40-100 keV(每10 keV递增)虚拟单能图像,定量测量图像噪声及胰腺、肿瘤、动脉、静脉的对比噪声比,并由两名放射科医师独立进行5分制主观评分,同时计算体型特异性剂量估算值。
关键影像表现/征象
- VMI40-100的图像噪声显著低于PEI(p < 0.01)。
- CNR随能量降低逐渐升高,VMI40-60的CNR显著高于PEI(p < 0.01)。
- 所有主观VMI评分在VMI40最高,其次为VMI50-60,均显著优于PEI(p < 0.01)。
- 门静脉期VMI40-50的客观与主观图像质量等同或优于常规胰腺实质期图像。
诊断标准与关键数值
- 主观评估采用5分制,评估肿瘤显示度、边缘勾画、图像噪声、胰管锐利度及动静脉显示。
- VMI40-100图像噪声显著低于PEI(p < 0.01);VMI40-60的CNR显著高于PEI(p < 0.01)。
- 所有主观VMI评分在VMI40最高,VMI50-60次之,均显著优于PEI(p < 0.01)。
- 门静脉期VMI40-50图像质量等同或优于常规胰腺实质期图像。
- 各期之间SSDE无显著差异(p = 0.10)。
临床应用与阅片要点
- 双层光谱CT多期胰腺扫描中,低keV虚拟单能图像(尤其40-50 keV)可提升胰腺导管腺癌的肿瘤显示度与胰腺周围血管显示。
- 门静脉期低keV虚拟单能图像可能允许在常规腹部CT上早期检出和局部分期胰腺导管腺癌。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the image quality and optimal energies of virtual monoenergetic images (VMIs) from dual-layer spectral detector computed tomography (DLCT) in multiphasic pancreatic CT and investigate whether low-keV VMI at the portal venous phase (PVP) provides sufficient tumor conspicuity and arterial depiction relative to conventional pancreatic parenchymal phase (PPP) images.
METHODS: Forty-eight patients with pancreatic ductal adenocarcinoma (PDAC) underwent contrast-enhanced DLCT during PPP and PVP. Conventional polyenergetic images (PEIs) and VMI at 40-100 keV (VMI40-100, 10-keV increments) were reconstructed at each enhancement phase. Image noise and the contrast-to-noise ratio (CNR) of the pancreas, tumors, arteries, and veins were quantified. Two radiologists independently assessed tumor conspicuity, margin delineation, image noise, sharpness of pancreatic duct, and depiction of arteries and veins on a five-point scale. Size-specific dose estimate (SSDE) was calculated.
RESULTS: Image noise for VMI40-100 was significantly lower than that for PEI (p < 0.01). The CNR in VMI increased gradually with decreasing energy; CNRs for VMI40-60 were significantly greater than that for PEI (p < 0.01). All subjective VMI scores were maximized at VMI40, followed by VMI50-60, all of which were significantly better than of PEI (p < 0.01). Objective and subjective image qualities of VMI40-50 at the PVP were equivalent to or even better compared with conventional PPP images. No significant difference in SSDE was observed between phases (p = 0.10).
CONCLUSIONS: DLCT-VMI improved the subjective and objective image quality in multiphasic pancreatic CT for patients with PDAC. Low-keV PVP imaging may yield diagnostically adequate tumor conspicuity and arterial assessment compared with polyenergetic PPP images.
KEY POINTS: • Low-keV VMI from DLCT yields better subjective and objective image quality of multiphasic pancreas CT in comparison with conventional PEI for the assessment of pancreatic ductal adenocarcinoma. • Tumor conspicuity and depiction of peripancreatic vasculature were maximized at VMI 40without an increase in the image noise. • Low-keV VMI of the portal venous phase provides sufficient tumor conspicuity and arterial depiction, potentially allowing the early detection and local staging of PDAC on routine abdominal CT performed for various clinical indications.
引用
- Nagayama Y, Tanoue S, Inoue T, et al. Dual-layer spectral CT improves image quality of multiphasic pancreas CT in patients with pancreatic ductal adenocarcinoma. Eur Radiol. 2019. PMID: 31312889. doi:10.1007/s00330-019-06337-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。