文献速递腹部泌尿生殖US

在有和无肝细胞癌风险的患者中鉴别肝内胆管癌与肝细胞癌:对比增强超声肝脏影像报告与数据系统2017版LR-M标准的评估

Distinguishing intrahepatic cholangiocarcinoma from hepatocellular carcinoma in patients with and without risks: the evaluation of the LR-M criteria of contrast-enhanced ultrasound liver imaging reporting and data system version 2017.
PubMed 文献 · Eur Radiol · 2019-07-11

本研究回顾性分析有风险和无风险患者的肝内胆管癌与匹配肝细胞癌病例,评估对比增强超声肝脏影像报告与数据系统2017版LR-M标准的诊断性能。结果显示LR-M标准鉴别肝内胆管癌与肝细胞癌的AUC为0.92、敏感度97.25%、特异度87.72%、准确率92.38%;将早期廓清起始时间调整为<45秒后,特异度显著提高至95.61%(p=0.004)而敏感度未降低(96.33%,p=0.945)。

要点

  • LR-M标准鉴别肝内胆管癌与肝细胞癌的AUC为0.92、敏感度97.25%、特异度87.72%、准确率92.38%。
  • 早期廓清起始时间调整为<45秒后特异度由87.72%升至95.61%(p=0.004),敏感度未降低(96.33%,p=0.945)。
  • 肝细胞癌误诊为肝内胆管癌的比例由12.3%降至4.4%。

核心结论

  • LR-M标准在有和无肝细胞癌风险的患者中鉴别肝内胆管癌与肝细胞癌均显示高敏感度,但调整当前标准后特异度显著提高。

研究设计与样本

  • 回顾性分析纳入有风险患者的肝内胆管癌54例、无风险患者的肝内胆管癌55例,以及匹配的有风险和无风险肝细胞癌对照病例分别为59例和55例。
  • 根据LR-M标准回顾性分析病灶的增强特征,评估LR-M标准的AUC、敏感度和特异度等诊断性能。

关键影像表现/征象

  • 周边环状高增强、早期廓清(<45秒或60秒)和明显廓清在有风险与无风险肝内胆管癌之间无差异。
  • 无论患者有无风险因素,上述特征在肝内胆管癌中均比肝细胞癌更常见(p<0.05)。

诊断标准与关键数值

  • 采用LR-M标准鉴别肝内胆管癌与肝细胞癌的AUC为0.92、敏感度97.25%、特异度87.72%、准确率92.38%。
  • 将早期廓清起始时间调整为<45秒后,特异度显著提高至95.61%(p=0.004),敏感度为96.33%(p=0.945),未降低敏感度。
  • 调整后肝细胞癌误诊为肝内胆管癌的比例由12.3%降至4.4%。

临床应用与阅片要点

  • LR-M标准可用于有肝细胞癌风险因素的患者,也可用于无风险因素的患者,以鉴别肝内胆管癌与肝细胞癌。
  • 将早期廓清起始时间调整为<45秒可提高特异度并减少肝细胞癌误诊为肝内胆管癌,且不损失敏感度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the diagnostic performance of the LR-M criteria of Contrast-Enhanced Ultrasound Liver Imaging Reporting and Data System version 2017 in differentiating intrahepatic cholangiocarcinoma (ICC) from hepatocellular carcinoma (HCC) in patients with and without risk factors for HCC.

METHODS: Fifty-four ICC in patients with risks and 55 ICC in patients without risks and matched control cases of HCC with and without risks (n = 59 and n = 55, respectively) were enrolled. The enhanced features of the lesions were retrospectively analyzed according to LR-M criteria. The diagnostic performances including the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity of LR-M criteria were assessed.

RESULT: Peripheral rim-like hyperenhancement, early washout (< 45 or 60s), and marked washout did not differ between ICCs with and without risks, while all of these features were more common in ICCs than in HCCs (p < 0.05) no matter if patients were with and without risk factors. Using the LR-M criteria to differentiate ICC from HCC, the AUC, sensitivity, specificity, and accuracy were 0.92, 97.25%, 87.72%, and 92.38%, respectively. If early washout onset was adjusted to < 45 s, the specificity was significantly increased to 95.61% (p = 0.004) without losing sensitivity (96.33%, p = 0.945). The rate of HCCs misdiagnosed as ICCs would decrease from 12.3 to 4.4%.

CONCLUSION: Although the LR-M criteria showed high sensitivity in distinguishing ICCs from HCCs in patients with and without risks, the specificity would be significantly increased after adjustments to current criteria.

KEY POINTS: • The LR-M criteria of CEUS-LI-RADS v2017 could be used for distinguishing ICC from HCC not only in patients with risk factors for HCC but also in those without risk factors. • The diagnostic performance of differentiating ICC from HCC by using the LR-M criteria showed high AUC (0.92), high sensitivity (97.25%), intermediate specificity (87.72%), and high accuracy (92.38%). • If the onset of early washout was adjusted to < 45 s, the specificity was significantly increased from 87.72 to 95.61% (p = 0.004) without losing sensitivity (p = 0.945), and the rate of HCCs misdiagnosed as ICCs would decrease from 12.3 to 4.4%.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Li F, Li Q, Liu Y, et al. Distinguishing intrahepatic cholangiocarcinoma from hepatocellular carcinoma in patients with and without risks: the evaluation of the LR-M criteria of contrast-enhanced ultrasound liver imaging reporting and data system version 2017. Eur Radiol. 2019. PMID: 31297632. doi:10.1007/s00330-019-06317-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。