文献速递腹部MR

3 T 下呼吸触发联合同时多层加速改善肝脏扩散加权成像

Improved Liver Diffusion-Weighted Imaging at 3 T Using Respiratory Triggering in Combination With Simultaneous Multislice Acceleration.
PubMed 文献 · Invest Radiol · 2019-01-01

回顾性纳入52例在3 T行肝脏MRI的患者,比较呼吸触发联合同时多层加速的DWI(SMS-RT-DWI)与标准自由呼吸平面回波DWI(s-DWI)的伪影与图像质量。SMS-RT-DWI整体图像质量、肝缘锐利度及序列相关伪影评分均显著更优(P<0.05),采集时间快34%,两位阅片者对90.4%的检查整体更偏好SMS-RT-DWI。

要点

  • SMS-RT-DWI较s-DWI整体图像质量、肝缘锐利度及序列相关伪影评分均显著更优(P<0.05)。
  • SMS-RT-DWI采集时间较s-DWI快34%,两位阅片者对90.4%的检查整体更偏好SMS-RT-DWI。
  • s-DWI的ADC均值从左叶到右叶、从头侧到足侧递减,SMS-RT-DWI全肝ADC均值均匀。

核心结论

  • 优化的多层呼吸触发3 T肝脏DWI较s-DWI显著改善图像质量并缩短采集时间。

研究设计与样本

  • 回顾性研究纳入52例肝脏MRI患者,在3 T全身磁共振系统(MAGNETOM Skyra;Siemens Healthcare,Erlangen,德国)上均采集s-DWI与SMS-RT-DWI,由2名独立放射科医师定性评估,并测量信噪比图及肝各象限平均ADC。

关键影像表现/征象

  • SMS-RT-DWI的整体图像质量、肝缘锐利度及序列相关伪影评分均显著优于s-DWI(P<0.05)。
  • 两位阅片者对90.4%的检查整体更偏好SMS-RT-DWI而非s-DWI。
  • s-DWI的ADC均值呈从左叶到右叶、从头侧到足侧递减,SMS-RT-DWI全肝ADC均值均匀。

诊断标准与关键数值

  • 定性评估包括整体图像质量、肝缘锐利度、序列相关伪影及整体扫描偏好。
  • 定量评估包括信噪比图测得的信噪比及肝各象限平均ADC。
  • s-DWI在b50时信噪比显著更高,b800时无统计学差异;SMS-RT-DWI信噪比更均匀,b50时标准差显著更低。

临床应用与阅片要点

  • SMS-RT-DWI采集时间较s-DWI快34%,可用于缩短肝脏DWI扫描时间。
  • s-DWI的ADC值随肝叶与头足方向递减,SMS-RT-DWI全肝ADC均匀,阅片测ADC时需注意序列相关的空间差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to retrospectively compare optimized respiratory-triggered diffusion-weighted imaging with simultaneous multislice acceleration (SMS-RT-DWI) of the liver with a standard free-breathing echo-planar DWI (s-DWI) protocol at 3 T with respect to the imaging artifacts inherent to DWI.

MATERIALS AND METHODS: Fifty-two patients who underwent a magnetic resonance imaging study of the liver were included in this retrospective study. Examinations were performed on a 3 T whole-body magnetic resonance system (MAGNETOM Skyra; Siemens Healthcare, Erlangen, Germany). In all patients, both s-DWI and SMS-RT-DWI of the liver were obtained. Images were qualitatively evaluated by 2 independent radiologists with regard to overall image quality, liver edge sharpness, sequence-related artifacts, and overall scan preference. For quantitative evaluation, signal-to-noise ratio was measured from signal-to-noise ratio maps. The mean apparent diffusion coefficient (ADC) was measured in each liver quadrant. The Wilcoxon rank-sum test was used for analysis of the qualitative parameters and the paired Student t test for quantitative parameters.

RESULTS: Overall image quality, liver edge sharpness, and sequence-related artifacts of SMS-RT-DWI received significantly better ratings compared with s-DWI (P < 0.05 for all). For 90.4% of the examinations, both readers overall preferred SMS-RT-DWI to s-DWI. Acquisition time for SMS-RT-DWI was 34% faster than s-DWI. Signal-to-noise ratio values were significantly higher for s-DWI at b50 but did not statistically differ at b800, and they were more homogenous for SMS-RT-DWI, with a significantly lower standard deviation at b50. Mean ADC values decreased from the left to right hepatic lobe as well as from cranial to caudal for s-DWI. With SMS-RT-DWI, mean ADC values were homogeneous throughout the liver.

CONCLUSIONS: Optimized, multislice, respiratory-triggered DWI of the liver at 3 T substantially improves image quality with a reduced scan acquisition time compared with s-DWI.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Tavakoli A, Attenberger UI, Budjan J, et al. Improved Liver Diffusion-Weighted Imaging at 3 T Using Respiratory Triggering in Combination With Simultaneous Multislice Acceleration. Invest Radiol. 2019. PMID: 31335634. doi:10.1097/RLI.0000000000000594

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。