文献速递腹部MRUS

瞬时弹性成像、点剪切波弹性成像与磁共振弹性成像用于肝纤维化分期的前瞻性比较

Prospective comparison of transient, point shear wave, and magnetic resonance elastography for staging liver fibrosis.
PubMed 文献 · Eur Radiol · 2019-07-05

这项前瞻性、横断面、双中心影像研究纳入100例已知或疑似慢性肝病(乙肝/丙肝、非酒精性脂肪性肝病或自身免疫性肝炎)患者,在肝活检6周内用瞬時弹性成像(TE)、点剪切波弹性成像(pSWE)和磁共振弹性成像(MRE)测量肝硬度。MRE在区分F0 vs ≥F1和≤F1 vs ≥F2时AUC显著高于TE和pSWE,MRE对早期肝纤维化分期的诊断效能更高。

要点

  • MRE区分F0 vs ≥F1的AUC为0.88,显著高于TE的0.71和pSWE的0.73(p<0.05)。
  • MRE区分≤F1 vs ≥F2的AUC为0.85,显著高于TE的0.75(p<0.05)。
  • TE、pSWE和MRE的技术可行且可靠比例分别为92%、79%和91%。

核心结论

  • MRE对早期肝纤维化分期的诊断效能高于TE和pSWE。
  • 三种弹性成像技术测得的肝硬度均随纤维化分期和炎症增加而升高,随脂肪变性增加而降低。

研究设计与样本

  • 前瞻性、横断面、双中心影像研究,纳入100例已知或疑似慢性肝病(乙肝或丙肝病毒、非酒精性脂肪性肝病或自身免疫性肝炎所致)患者,于2014年至2018年间识别。
  • 在肝活检6周内采用TE、pSWE和MRE三种弹性成像技术测量肝硬度。
  • 评估炎症和脂肪变性对纤维化与肝硬度关联的混杂效应,采用Obuchowski评分和AUC评价纤维化分期,AUC比较采用DeLong方法。
  • 试验注册号:NCT02044523。

诊断标准与关键数值

  • TE、pSWE和MRE技术可行且可靠的比例分别为92%、79%和91%。
  • 区分F0 vs ≥F1的AUC:MRE 0.88 vs TE 0.71(p<0.05);MRE 0.88 vs pSWE 0.73(p<0.05)。
  • 区分≤F1 vs ≥F2的AUC:MRE 0.85 vs TE 0.75(p<0.05)。
  • 纤维化分期的Obuchowski评分:TE 0.89(95%CI 0.85-0.93),pSWE 0.90(95%CI 0.85-0.94),MRE 0.94(95%CI 0.91-0.96)。

临床应用与阅片要点

  • 在需要无创评估早期肝纤维化分期时,MRE对区分F0 vs ≥F1和≤F1 vs ≥F2的诊断效能高于TE和pSWE。
  • 解读肝硬度值时需考虑炎症可使其升高、脂肪变性可使其降低的混杂效应。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To perform head-to-head comparisons of the feasibility and diagnostic performance of transient elastography (TE), point shear-wave elastography (pSWE), and magnetic resonance elastography (MRE).

METHODS: This prospective, cross-sectional, dual-center imaging study included 100 patients with known or suspected chronic liver disease caused by hepatitis B or C virus, nonalcoholic fatty liver disease, or autoimmune hepatitis identified between 2014 and 2018. Liver stiffness measured with the three elastographic techniques was obtained within 6 weeks of a liver biopsy. Confounding effects of inflammation and steatosis on association between fibrosis and liver stiffness were assessed. Obuchowski scores and AUCs for staging fibrosis were evaluated and the latter were compared using the DeLong method.

RESULTS: TE, pSWE, and MRE were technically feasible and reliable in 92%, 79%, and 91% subjects, respectively. At univariate analysis, liver stiffness measured by all techniques increased with fibrosis stages and inflammation and decreased with steatosis. For classification of dichotomized fibrosis stages, the AUCs were significantly higher for distinguishing stages F0 vs. ≥ F1 with MRE than with TE (0.88 vs. 0.71; p < 0.05) or pSWE (0.88 vs. 0.73; p < 0.05), and for distinguishing stages ≤ F1 vs. ≥ F2 with MRE than with TE (0.85 vs. 0.75; p < 0.05). TE, pSWE, and MRE Obuchowski scores for staging fibrosis stages were respectively 0.89 (95% CI 0.85-0.93), 0.90 (95% CI 0.85-0.94), and 0.94 (95% CI 0.91-0.96).

CONCLUSION: MRE provided a higher diagnostic performance than TE and pSWE for staging early stages of liver fibrosis.

TRIAL REGISTRATION: NCT02044523 KEY POINTS: • The technical failure rate was similar between MRE and US-based elastography techniques. • Liver stiffness measured by MRE and US-based elastography techniques increased with fibrosis stages and inflammation and decreased with steatosis. • MRE provided a diagnostic accuracy higher than US-based elastography techniques for staging of early stages of histology-determined liver fibrosis.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Lefebvre T, Wartelle-Bladou C, Wong P, et al. Prospective comparison of transient, point shear wave, and magnetic resonance elastography for staging liver fibrosis. Eur Radiol. 2019. PMID: 31278577. doi:10.1007/s00330-019-06331-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。