血管长度是否影响320排冠状动脉CT血管造影的跨腔衰减梯度?与有创血管造影的相关性
本研究回顾性纳入52例患者的150支冠状动脉,评估血管长度对跨腔衰减梯度(TAG)的影响,并建立新指标VLN-TAG(HU/100 mm²)=TAG(HU/10 mm)/血管长度(10 mm)。结果显示TAG与血管长度显著相关(r=0.644,p<0.001),TAG和VLN-TAG在不同狭窄程度组间无显著差异,联合CCTA未显著改变AUC;在钙化血管组,加用VLN-TAG使特异度从85.71%提高至92.86%。
要点
- TAG与血管长度显著相关(r=0.644,p<0.001),血管长度是影响TAG的重要因素。
- TAG或VLN-TAG联合CCTA未显著改变诊断冠状动脉狭窄的AUC。
- 钙化血管组加用VLN-TAG后特异度由85.71%升至92.86%。
核心结论
- 血管长度是影响TAG的重要因素;与单独CCTA相比,TAG未提供增量诊断价值;VLN-TAG在钙化血管组可能轻微提高特异度(92.86 vs 85.71%)。
研究设计与样本
- 回顾性纳入52例患者共150支冠状动脉,均于2周内行320排CT单心跳扫描和有创冠状动脉造影(ICA);从三大心外膜血管获取TAG,用Pearson相关和回归分析评估TAG与血管长度的关系,用重复测量方差分析比较不同狭窄程度下TAG和VLN-TAG的变化。
诊断标准与关键数值
- TAG与血管长度显著相关(r=0.644,p<0.001);ICA狭窄程度<50%、50-70%、70-99%三组间TAG和VLN-TAG均无显著差异;斑块成分对各组VLN-TAG无影响;联合TAG或VLN-TAG与CCTA未显著改变AUC;钙化血管组加用VLN-TAG特异度为92.86% vs 单用CCTA 85.71%。
临床应用与阅片要点
- 作者指出血管长度是影响TAG的重要因素,TAG相比单独CCTA未提供增量诊断价值;在钙化血管组加用VLN-TAG可能轻微提高特异度。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study aimed to investigate the influence of vessel length on transluminal attenuation gradient (TAG) and establish a new index, VLN-TAG (VLN-TAG (HU/100 mm2) = TAG (HU/10 mm)/vessel length (10 mm)), to estimate the diagnostic value using 320-slice computed tomography (CT).
METHODS: A total of 150 coronary arteries from 52 patients who underwent single-beat scanning using 320-slice CT and invasive coronary angiography (ICA) within 2 weeks were retrospectively enrolled. TAG was obtained from the major three epicardial vessels, and its interrelation with the measured length of the vessels was evaluated by Pearson correlation and regression analyses. The changes in TAG and VLN-TAG were compared with the corresponding stenosis severities ascertained by ICA using repeated measures ANOVA.
RESULTS: TAG had a significant interrelation with the measured length of the vessels (r = 0.644, p < 0.001). Neither TAG nor VLN-TAG with different stenosis degrees of < 50, 50-70, and 70-99% on ICA had significant difference among the three groups. Plaque composition had no influence on VLN-TAG in all groups. The combined TAG or VLN-TAG and coronary computed tomography angiography (CCTA) assessment did not significantly change the area under the curve compared with using CCTA only. In the calcified vessels group, adding VLN-TAG to CCTA improved the specificity (92.86 vs 85.71%).
CONCLUSIONS: Vessel length is an important factor impacting TAG. TAG does not offer an incremental diagnostic value compared with CCTA only for detecting coronary stenosis.
KEY POINTS: • Transluminal attenuation gradient (TAG) does not improve the diagnostic value of CCTA. Vessel length impacts TAG, but VLN-TAG does not improve the diagnostic value of CCTA. • Plaque composition had no influence on VLN-TAG in all groups of stenosis degrees. There may be a minimal improvement in specificity when VLN-TAG is applied to the calcified vessels group.
引用
- Xu N, Peng K, Dai S, et al. Does vessel length impact transluminal attenuation gradient in 320-slice coronary CT angiography? Correlation with invasive angiography. Eur Radiol. 2019. PMID: 31264012. doi:10.1007/s00330-019-06311-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。