文献速递心血管CTDSA

双屏气改良减影冠状动脉CT血管成像:冠状动脉钙化患者的图像质量与诊断准确性

Modified Subtraction Coronary CT Angiography with a Two-Breathhold Technique: Image Quality and Diagnostic Accuracy in Patients with Coronary Calcifications.
PubMed 文献 · Korean J Radiol · 2019-01-01

研究纳入128例患者,其中32例接受减影CCTA及有创冠状动脉造影(ICA),平均Agatston评分356±145。在严重钙化节段,减影CCTA较常规CCTA显著提高图像质量(2.51±0.98 vs 3.12±0.94,p<0.001)、特异度(70% vs 87%,p=0.005)和阳性预测值(61% vs 79%,p<0.01),且基于节段的诊断准确率更高(AUC 0.94 vs 0.85,p=0.03)。结论认为该改良减影法错位配准更少、图像质量更好,并允许对严重钙化节段进行狭窄再分级。

要点

  • 在严重钙化冠状动脉节段,减影CCTA的图像质量评分显著高于常规CCTA(3.12±0.94 vs 2.51±0.98,p<0.001)。
  • 减影CCTA较常规CCTA提高特异度(87% vs 70%,p=0.005)和阳性预测值(79% vs 61%,p<0.01),阴性预测值无损失。
  • 基于节段检测显著狭窄的诊断准确率,减影CCTA优于常规CCTA(AUC 0.94 vs 0.85,p=0.03)。

核心结论

  • 该改良双屏气减影CCTA方法在屏气能力有限的患者中表现出更低的错位配准和更好的图像质量。
  • 与常规CCTA相比,改良减影CCTA可对严重钙化冠状动脉节段进行狭窄再分级并提高诊断准确性。

研究设计与样本

  • 本研究经机构审查委员会批准,所有受试者均提供书面知情同意。
  • 共招募128例患者进入本试验,其中32例接受了减影CCTA扫描和有创冠状动脉造影(ICA)。
  • 平均Agatston评分为356±145。
  • 以有创冠状动脉造影(ICA)所见作为金标准,对严重钙化冠状动脉节段在常规CCTA和减影CCTA图像上评估是否存在显著(>50%)狭窄,并将结果与ICA所见进行比较。

关键影像表现/征象

  • 在严重钙化节段,常规CCTA的图像质量为2.51±0.98,减影CCTA为3.12±0.94,减影CCTA显著改善(p<0.001)。

诊断标准与关键数值

  • 在目标节段,常规CCTA特异度为70%、阳性预测值为61%,减影CCTA特异度为87%(p=0.005)、阳性预测值为79%(p<0.01),减影CCTA较常规CCTA提高且阴性预测值无损失。
  • 基于节段检测显著狭窄的诊断准确率:减影CCTA的ROC曲线下面积为0.94,常规CCTA为0.85(p=0.03)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate a modified subtraction coronary computed tomography angiography (CCTA) technique with a two-breathhold approach in terms of image quality and stenosis grading of calcified coronary segments and in the detection of significant coronary stenosis in segments with severe calcification.

MATERIALS AND METHODS: The institutional board approved this study, and all subjects provided written consent. A total of 128 patients were recruited into this trial, of which 32 underwent subtraction CCTA scans and invasive coronary angiography (ICA). The average Agatston score was 356 ± 145. In severely calcified coronary segments, the presence of significant (> 50%) stenosis was assessed on both conventional CCTA and subtraction CCTA images, and the results were finally compared with ICA findings as the gold standard.

RESULTS: For severely calcified segments, the image quality in conventional CCTA significantly improved from 2.51 ± 0.98 to 3.12 ± 0.94 in subtraction CCTA (p < 0.001). In target segments, specificity (70% vs. 87%; p = 0.005) and positive predictive value (61% vs. 79%, p < 0.01) were improved using subtraction CCTA in comparison with conventional CCTA, with no loss in the negative predictive value. The segment-based diagnostic accuracy for detecting significant stenosis was significantly better in subtraction CCTA than in conventional CCTA (area under the receiver operating characteristic curve, 0.94 vs. 0.85; p = 0.03).

CONCLUSION: This modified subtraction CCTA method showed lower misregistration and better image quality in patients with limited breathhold capability. In comparison with conventional CCTA, modified subtraction CCTA would allow stenosis regrading and improve the diagnostic accuracy in coronary segments with severe calcification.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Guo W, Tripathi P, Yang S, et al. Modified Subtraction Coronary CT Angiography with a Two-Breathhold Technique: Image Quality and Diagnostic Accuracy in Patients with Coronary Calcifications. Korean J Radiol. 2019. PMID: 31270978. doi:10.3348/kjr.2018.0845

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。