虚拟平扫与真实平扫双层双能CT对主动脉壁内血肿诊断的对比研究
该研究通过体模和临床两部分,评估对比增强双层双能CT生成的虚拟平扫(VNC)能否替代真实平扫(TNC)诊断主动脉壁内血肿(IMH)。结果显示VNC与TNC的血肿-管腔对比噪声比相似,诊断信心相当(VNC 3.2±0.7 vs TNC 3.1±0.7,p=0.3),省略TNC可降低平均有效剂量40%。作者认为双层双能CT的VNC与TNC诊断IMH性能相似且不损害图像质量。
要点
- 双层双能CT可从增强扫描生成虚拟平扫,用于诊断主动脉壁内血肿。
- VNC与TNC的血肿-管腔CNR相似,诊断信心相当。
- 采用VNC替代TNC可使急性主动脉综合征成像方案平均有效剂量降低40%。
核心结论
- 双层双能CT的虚拟平扫与真实平扫在主动脉壁内血肿诊断中性能相似,且不损害诊断图像质量。
研究设计与样本
- 体模研究加双中心回顾性临床研究;临床纳入21例确诊IMH患者(70±13岁),在120 kVp下接受急性主动脉综合征成像方案。
关键影像表现/征象
- VNC与TNC图像均能区分血肿内高衰减与血液。
- 体模与临床研究中VNC和TNC的血肿-管腔CNR均相似。
诊断标准与关键数值
- 诊断信心评分:1分为不可诊断,4分为极佳;VNC 3.2±0.7 vs TNC 3.1±0.7,p=0.3。
- 省略TNC采集并使用VNC时,平均有效剂量降低40%。
临床应用与阅片要点
- 在急性主动脉综合征成像方案中,可考虑用双层双能CT的虚拟平扫替代真实平扫以减少采集次数和辐射暴露。
- 双层双能CT有潜力成为急性主动脉综合征的合适成像工具。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess whether virtual non-contrast (VNC) images derived from contrast dual-layer dual-energy computed tomography (DL-DECT) images could replace true non-contrast (TNC) images for aortic intramural hematoma (IMH) diagnosis in acute aortic syndrome (AAS) imaging protocols by performing quantitative as well as qualitative phantom and clinical studies.
MATERIALS AND METHODS: Patients with confirmed IMH were included retrospectively in two centers. For in vitro imaging, a custom-made phantom of IMH was placed in a semi-anthropomorphic thorax phantom (QRM GmbH) and imaged on a DL-DECT at 120 kVp under various conditions of patient size, radiation exposure, and reconstruction modes. For in vivo imaging, 21 patients (70 ± 13 years) who underwent AAS imaging protocols at 120 kVp were included. In both studies, contrast-to-noise ratio (CNR) between hematoma and lumen was compared using a paired t test. Diagnostic confidence (1 = non-diagnostic, 4 = exemplary) for VNC and TNC images was rated by two radiologists and compared. Effective radiation doses for each acquisition were calculated.
RESULTS: In both the phantom and clinical studies, we observed that the CNRs were similar between the VNC and TNC images. Moreover, both methods allowed differentiating the hyper-attenuation within the hematoma from the blood. Finally, we obtained equivalent high diagnostic confidence with both VNC and TNC images (VNC = 3.2 ± 0.7, TNC = 3.1 ± 0.7; p = 0.3). Finally, by suppressing TNC acquisition and using VNC, the mean effective dose reduction would be 40%.
CONCLUSION: DL-DECT offers similar performances with VNC and TNC images for IMH diagnosis without compromise in diagnostic image quality.
KEY POINTS: • Dual-layer dual-energy CT enables virtual non-contrast imaging from a contrast-enhanced acquisition. • Virtual non-contrast imaging with dual-layer dual-energy CT reduces the number of acquisitions and radiation exposure in acute aortic syndrome imaging protocol. • Dual-layer dual-energy CT has the potential to become a suitable imaging tool for acute aortic syndrome.
引用
- Si-Mohamed S, Dupuis N, Tatard-Leitman V, et al. Virtual versus true non-contrast dual-energy CT imaging for the diagnosis of aortic intramural hematoma. Eur Radiol. 2019. PMID: 31264015. doi:10.1007/s00330-019-06322-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。