主动脉超声时谐弹性成像:年龄与高血压对主动脉僵硬度的影响
该前瞻性研究纳入74名参与者(50名健康者、24名长期高血压患者),于2018年1月至10月行上腹部主动脉超声时谐弹性成像,以剪切波速度(SWS)作为组织僵硬度替代指标。线性回归显示年龄对SWS有显著影响,每年增加0.024 m/s(P<0.001);年龄校正后高血压组SWS显著高于健康组(0.24 m/s vs 0.07 m/s,P<0.001)。以0.15 m/s为截断值鉴别两组最佳,AUC为0.966(95%CI 0.93-1.0),敏感度83%、特异度98%。
要点
- 年龄校正后高血压组SWS为0.24 m/s,健康组为0.07 m/s,两组差异显著(P<0.001)。
- 以SWS截断值0.15 m/s鉴别高血压与健康者,AUC 0.966,敏感度83%、特异度98%。
- 观察者间与观察者内一致性优异,ICC分别为0.987和0.937。
核心结论
- 上腹部主动脉超声时谐弹性成像可在体内定量主动脉壁僵硬度,高血压患者SWS值显著高于健康者。
研究设计与样本
- 前瞻性研究,纳入74名参与者(50名健康者、24名长期高血压患者),于2018年1月至10月行上腹部主动脉超声时谐弹性成像,参考标准为年龄校正SWS、血压和脉搏波速度。
关键影像表现/征象
- 基于多频波场生成剪切波速度复合图,覆盖B型超声全视野,作为组织僵硬度替代指标。
诊断标准与关键数值
- 年龄对SWS有显著影响,每年增加0.024 m/s(P<0.001)。
- 年龄校正后高血压组SWS为0.24 m/s(IQR 0.17-0.40 m/s),健康组为0.07 m/s(IQR -0.01至0.06 m/s),P<0.001。
- 以0.15 m/s为截断值鉴别两组最佳,AUC 0.966(95%CI 0.93-1.0,P<0.001),敏感度83%、特异度98%。
- 观察者间ICC 0.987,观察者内ICC 0.937。
- 短期重复测量ICC 0.968(CI 0.878-0.992),长期(6个月)重复测量ICC 0.844(CI 0.491-0.959)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to investigate ultrasound time-harmonic elastography for quantifying aortic stiffness in vivo in the context of aging and arterial hypertension.
MATERIALS AND METHODS: Seventy-four participants (50 healthy participants and 24 participants with long-standing hypertension) were prospectively included between January 2018 and October 2018, and underwent ultrasound time-harmonic elastography of the upper abdominal aorta. Compound maps of shear-wave speed (SWS) as a surrogate of tissue stiffness were generated from multifrequency wave fields covering the full field-of-view of B-mode ultrasound. Blood pressure and pulse wave velocity were measured beforehand. Interobserver and intraobserver agreement was determined in 30 subjects. Reproducibility of time-harmonic elastography was assessed in subgroups with repeated measurements after 20 minutes and after 6 months. Linear regression analysis, with subsequent age adjustment of SWS obtained, receiver operating characteristic analysis, and intraclass correlation coefficients (ICCs) were used for statistical evaluation.
RESULTS: Linear regression analysis revealed a significant effect of age on SWS with an increase by 0.024 m/s per year (P < 0.001). Age-adjusted SWS was significantly greater in hypertensives (0.24 m/s; interquartile range [IQR], 0.17-0.40 m/s) than in healthy participants (0.07 m/s; IQR, -0.01 to 0.06 m/s; P < 0.001). A cutoff value of 0.15 m/s was found to differentiate best between groups (area under the receiver operating characteristic curve, 0.966; 95% confidence interval, 0.93-1.0; P < 0.001; 83% sensitivity and 98% specificity). Interobserver and intraobserver variability was excellent (ICC, 0.987 and 0.937, respectively). Reproducibility was excellent in the short term (ICC, 0.968; confidence interval, 0.878-0.992) and good in the long term (ICC, 0.844; confidence interval, 0.491-0.959).
CONCLUSIONS: Ultrasound time-harmonic elastography of the upper abdominal aorta allows quantification of aortic wall stiffness in vivo and shows significantly higher values in patients with arterial hypertension.
引用
- Schaafs LA, Tzschätzsch H, Reshetnik A, et al. Ultrasound Time-Harmonic Elastography of the Aorta: Effect of Age and Hypertension on Aortic Stiffness. Invest Radiol. 2019. PMID: 31299035. doi:10.1097/RLI.0000000000000590
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。