PubMed 文献 · Radiology · 2019-07-23

研究纳入ADVANCE注册库中2778例与临床连续10621例冠状动脉CT血管成像,FFRCT拒绝率分别为2.9%与8.4%,主要原因为运动伪影;多层螺旋CT层厚与心率是拒绝的独立预测因素。

要点

  • FFRCT拒绝率在ADVANCE注册库为2.9%,临床连续队列为8.4%。
  • 无法完成FFRCT分析的主要原因是运动伪影(78%与64%)。
  • 层厚与心率是FFRCT拒绝的独立预测因素。

核心结论

  • ADVANCE注册库与大型临床队列中CT衍生血流储备分数技术失败率分别为2.9%和8.4%。
  • 更薄的CT层厚与更低的心率可能提高CT血流储备分数分析的完成率。

研究设计与样本

  • 研究纳入ADVANCE注册库(NCT02499679)前瞻性采集的冠状动脉CT血管成像扫描以及提交临床分析的冠状动脉CT血管成像序列。
  • ADVANCE注册库队列2778例,临床连续分析队列10621例。
  • 主要结局为FFRCT拒绝率,定义为无法进行FFRCT定量分析。
  • 采用多元线性回归评估与FFRCT拒绝率相关的因素。

关键影像表现/征象

  • 无法进行FFRCT分析的主要原因为运动伪影,ADVANCE队列80例中63例(78%),临床队列892例中729例(64%)。

诊断标准与关键数值

  • ADVANCE注册库中因图像质量不足导致的FFRCT拒绝率为2.9%(80/2778,95%CI:2.1%,3.2%)。
  • 临床连续分析10621例中FFRCT拒绝率为8.4%(n=892,95%CI:6.2%,7.2%;与ADVANCE队列比较P<.001)。
  • 多变量分析中,ADVANCE队列层厚的OR为1.04(95%CI:1.001,1.09;P=.045),临床队列层厚的OR为1.03(95%CI:1.02,1.04;P<.001)。
  • 多变量分析中,ADVANCE队列心率的OR为1.05(95%CI:1.02,1.08;P<.001),临床队列心率的OR为1.06(95%CI:1.05,1.07;P<.001)。

临床应用与阅片要点

  • 原文指出更薄的CT层厚与更低的心率可能提高CT血流储备分数分析的完成率。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Coronary artery fractional flow reserve (FFR) derived from CT angiography (FFTCT) enables functional assessment of coronary stenosis. Prior clinical trials showed 13%-33% of coronary CT angiography studies had insufficient quality for quantitative analysis with FFRCT. Purpose To determine the rejection rate of FFRCT analysis and to determine factors associated with technically unsuccessful calculation of FFRCT. Materials and Methods Prospectively acquired coronary CT angiography scans submitted as part of the Assessing Diagnostic Value of Noninvasive FFRCT in Coronary Care (ADVANCE) registry (https://ClinicalTrials.gov: NCT02499679) and coronary CT angiography series submitted for clinical analysis were included. The primary outcome was the FFRCT rejection rate (defined as an inability to perform quantitative analysis with FFRCT). Factors that were associated with FFRCT rejection rate were assessed with multiple linear regression. Results In the ADVANCE registry, FFRCT rejection rate due to inadequate image quality was 2.9% (80 of 2778 patients; 95% confidence interval [CI]: 2.1%, 3.2%). In the 10 621 consecutive patients who underwent clinical analysis, the FFRCT rejection rate was 8.4% (n = 892; 95% CI: 6.2%, 7.2%; P < .001 vs the ADVANCE cohort). The main reason for the inability to perform FFRCT analysis was the presence of motion artifacts (63 of 80 [78%] and 729 of 892 [64%] in the ADVANCE and clinical cohorts, respectively). At multivariable analysis, section thickness in the ADVANCE (odds ratio [OR], 1.04; 95% CI: 1.001, 1.09; P = .045) and clinical (OR, 1.03; 95% CI: 1.02, 1.04; P < .001) cohorts and heart rate in the ADVANCE (OR, 1.05; 95% CI: 1.02, 1.08; P < .001) and clinical (OR, 1.06; 95% CI: 1.05, 1.07; P < .001) cohorts were independent predictors of rejection. Conclusion The rates for technically unsuccessful CT-derived fractional flow reserve in the ADVANCE registry and in a large clinical cohort were 2.9% and 8.4%, respectively. Thinner CT section thickness and lower patient heart rate may increase rates of completion of CT fractional flow reserve analysis. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Sakuma in this issue.