文献速递胸部CT

接受立体定向体部放疗的小肺肿瘤患者:16排多探测器CT与320排区域探测器CT的肿瘤体积比较——呼吸运动的影响

Tumour volume comparison between 16-row multi-detector computed tomography and 320-row area-detector computed tomography in patients with small lung tumours treated with stereotactic body radiotherapy: Effect of respiratory motion.
PubMed 文献 · Eur J Radiol · 2019-06-08

本研究在运动模体和12例接受立体定向体部放疗的肺癌患者中,比较16排多探测器CT与320排区域探测器CT测得的肿瘤体积及图像质量,并评估各呼吸时相的体积。结果显示320排区域探测器CT测得的肿瘤体积更小且更接近静态图像,各呼吸时相体积显著小于16排多探测器CT。

要点

  • 320排区域探测器CT测得的肿瘤体积较16排多探测器CT更小,且更接近静态/屏气图像。
  • 临床研究中,16排多探测器CT(2.5 mm层厚)平均肿瘤体积为9.58±1.07 cm³,320排区域探测器CT为7.12±0.23 cm³(p<0.01)。
  • 320排区域探测器CT在呼气末/吸气末时相的肿瘤体积小于呼吸中期时相,而16排多探测器CT未见此表现。

核心结论

  • 320排区域探测器CT在各呼吸时相测得的肿瘤体积显著小于16排多探测器CT,且更接近静态图像。
  • 作者提示,若在治疗计划中使用320排区域探测器CT,治疗体积可能得以缩小。

研究设计与样本

  • 研究采用运动模体(振幅10 mm和30 mm,三种运动周期2、4、6秒)获取静态和四维CT图像,并行屏气与四维CT采集12例接受立体定向体部放疗的肺癌患者。
  • 图像数据分别通过16排多探测器CT和320排区域探测器CT采集,在各呼吸时相勾画肿瘤并比较呼气末/吸气末时相与呼吸中期时相的体积。

诊断标准与关键数值

  • 模体研究中,320排区域探测器CT测得的肿瘤体积较16排多探测器CT更小且更接近静态图像。
  • 临床研究中,平均肿瘤体积±标准差为16排多探测器CT(2.5 mm层厚)9.58±1.07 cm³,320排区域探测器CT 7.12±0.23 cm³(p<0.01)。
  • 所有患者经320排区域探测器CT测得的肿瘤体积均较16排多探测器CT更接近屏气CT的体积。
  • 与16排多探测器CT不同,320排区域探测器CT在呼气末或吸气末时相的肿瘤体积小于呼吸中期时相。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: We compared image quality and volume of a moving simulated tumour and of lung tumours in patients who were treated with stereotactic body radiotherapy (SBRT) in a 16-row multi-detector CT (MDCT) versus a 320-row area-detector CT (ADCT). Tumour volumes in each respiratory phase were also evaluated.

MATERIALS AND METHODS: We acquired static and four-dimensional CT (4DCT) images of a moving phantom with 10- and 30-mm amplitudes with three periods of patterns (2, 4, and 6 s). Breath-hold and 4DCT images were acquired for 12 lung tumour patients who underwent SBRT. Image data were acquired via MDCT and ADCT. The tumours were delineated in each respiratory phase and their volumes in end-expiratory/end-inspiratory phase and mid-respiratory phase were compared.

RESULTS: In the phantom study, tumour volumes were smaller and closer to the static image when evaluated by ADCT than by MDCT. In the clinical study, average tumour volumes ± standard deviations were 9.58 ± 1.07 cm3 with MDCT (2.5-mm slice), and 7.12 ± 0.23 cm3 with ADCT (p < 0.01). Tumour volumes were closer to that of the breath hold CT in all patients evaluated by ADCT than by MDCT. Unlike MDCT, tumour volumes acquired by ADCT were smaller in end-expiratory or end-inspiratory phase than in the mid-respiratory phase.

CONCLUSIONS: Tumour volumes in each of the respiratory phases in ADCT were significantly smaller and closer to the static image than the corresponding volumes in MDCT. This suggests that treated volume can be reduced if ADCT is used in treatment planning.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Iizuka Y, Nakamura M, Kozawa S, et al. Tumour volume comparison between 16-row multi-detector computed tomography and 320-row area-detector computed tomography in patients with small lung tumours treated with stereotactic body radiotherapy: Effect of respiratory motion. Eur J Radiol. 2019. PMID: 31307636. doi:10.1016/j.ejrad.2019.06.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。