一种测量脊柱畸形矢状面曲率的新方法:三维超声成像的可靠性与可行性
本研究在青少年特发性脊柱侧凸(AIS)患者中测试三维超声矢状面脊柱曲率测量的可靠性,测量超声棘突角(USSPA)和超声椎板角(USLA),并与矢状面X线Cobb角(XCA)比较。两种超声角度的测量信度均极好(ICC ≥ 0.91),与XCA呈中至高度显著线性相关且一致性良好,胸段R² ≥ 0.574、腰段R² ≥ 0.635,平均绝对差异无显著差异。作者认为该方法可靠、无电离辐射且成本较低,为AIS患者的频繁曲线监测和筛查提供了可能。
要点
- 三维超声矢状面测量USSPA和USLA的观察者内及观察者间信度均极好(ICC ≥ 0.91)。
- 超声角度与X线Cobb角呈中至高度显著线性相关,胸段R² ≥ 0.574、腰段R² ≥ 0.635。
- 超声角度与XCA的平均绝对差异无显著差异,一致性良好,可用于矢状面曲率评估。
核心结论
- 三维超声矢状面角度(USSPA、USLA)测量信度极好(ICC ≥ 0.91),与X线Cobb角呈中至高度显著线性相关且一致性良好,无电离辐射且成本相对较低,为AIS患者频繁曲线监测、评估和筛查提供了可能,尤其基于矢状面轮廓。
研究设计与样本
- 本研究为在青少年特发性脊柱侧凸(AIS)患者中测试三维超声矢状面脊柱曲率测量可靠性的研究。
- 在矢状面超声图像上测量超声棘突角(USSPA)和超声椎板角(USLA),在矢状面X线图像上测量Cobb角(XCA),并以XCA为参照比较两种超声角度。
- 采用组内相关系数(ICC)评估观察者内和观察者间变异,采用线性回归分析和Bland-Altman法(包括平均绝对差异MAD)评估两种超声角度与XCA相比的信度和效度。
诊断标准与关键数值
- 两种超声角度的测量信度均极好,ICC ≥ 0.91。
- 超声方法与XCA之间呈中至高度显著线性相关且一致性良好:胸段R² ≥ 0.574,腰段R² ≥ 0.635。
- 两种校正后超声角度与XCA的平均绝对差异(MAD)均无显著差异。
临床应用与阅片要点
- 矢状面超声角度可基于棘突和椎板可靠地评估矢状面曲率,并与X线Cobb角有良好且显著的相关性。
- 由于无电离辐射且成本相对较低,该方法为AIS患者提供频繁曲线监测、评估和筛查的可能性,尤其基于矢状面轮廓。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The objective of this study was to test the reliability of sagittal spinal curvature measurements using 3-D ultrasound in patients with adolescent idiopathic scoliosis (AIS). Ultrasound spinous process angle (USSPA) and ultrasound laminae angle (USLA) were measured on sagittal ultrasound images, while the Cobb angle (XCA) was measured on sagittal X-ray images. Intra-class correlation coefficients (ICC) for the intra- and inter-observer variability, linear regression analysis and Bland-Altman method, including mean absolute difference (MAD), were investigated to evaluate the reliability and validity of the two ultrasound angles compared with XCA. Excellent measurement reliabilities were demonstrated for both ultrasound angles (ICC ≥ 0.91). Moderate to good and significant linear correlations and good agreement were demonstrated between the ultrasound methods and XCA (Thoracic [R2 ≥ 0.574] / Lumbar [R2 ≥ 0.635]). No significant differences were found for the MADs between both corrected ultrasound angles and XCA. Sagittal ultrasound angles were demonstrated to be reliable for assessing sagittal curvature using spinous processes and laminae and to have good and significant correlations with XCAs. Since it is non-ionizing and relatively low cost, this method opens the possibility of providing frequent curve monitoring and evaluation, and screening for AIS patients, particularly based on sagittal profiles.
引用
- Lee TT, Jiang WW, Cheng CLK, et al. A Novel Method to Measure the Sagittal Curvature in Spinal Deformities: The Reliability and Feasibility of 3-D Ultrasound Imaging. Ultrasound Med Biol. 2019. PMID: 31303403. doi:10.1016/j.ultrasmedbio.2019.05.031
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。