文献速递胸部CTPET

表现为3厘米或更小磨玻璃密度结节的肺腺癌:高分辨率CT联合PET/CT评估

Lung Adenocarcinoma Manifesting as Ground-Glass Opacity Nodules 3 cm or Smaller: Evaluation With Combined High-Resolution CT and PET/CT Modality.
PubMed 文献 · AJR Am J Roentgenol · 2019-07-30

回顾性分析89例表现为3 cm或更小磨玻璃密度结节的肺腺癌患者,比较高分辨率CT与PET/CT参数鉴别浸润性腺癌与浸润前病变及微浸润腺癌。CT磨玻璃成分衰减值和SUV指数为独立预测因子,两者联合预测浸润性腺癌的准确率按结节计为81.4%、按患者计为85.4%。联合高分辨率CT与PET/CT的诊断敏感度和准确率高于单独形态学特征、高分辨率CT或PET/CT测量参数。

要点

  • CT磨玻璃成分衰减值和SUV指数是浸润性腺癌的独立预测因子。
  • 两者联合预测浸润性腺癌的准确率按结节计81.4%、按患者计85.4%。
  • 联合高分辨率CT与PET/CT的敏感度和准确率高于单独方法。

核心结论

  • 联合高分辨率CT与PET/CT是术前识别表现为3厘米或更小磨玻璃密度结节的肺腺癌中浸润性腺癌的有效方法。

研究设计与样本

  • 回顾性分析2011年11月至2018年11月间89例(24男、65女,平均年龄60.1±8.1岁,范围36-78岁)表现为3厘米或更小磨玻璃密度结节的肺腺癌患者的高分辨率CT和PET/CT参数。

关键影像表现/征象

  • 浸润性腺癌结节中混合磨玻璃密度型、多边形或不规则形状、分叶或毛刺边缘、支气管扩张扭曲或截断征的比例高于浸润前病变及微浸润腺癌结节。
  • 浸润性腺癌结节的CT磨玻璃成分衰减值、最大标准化摄取值和SUV指数(肿瘤最大SUV与肝脏平均SUV之比)均更高(p=0.001-0.022)。

诊断标准与关键数值

  • CT磨玻璃成分衰减值和SUV指数为浸润性腺癌结节的独立预测因子。
  • CT磨玻璃成分衰减值联合SUV指数预测浸润性腺癌的准确率按结节计为81.4%,按患者计为85.4%。
  • 联合高分辨率CT与PET/CT的敏感度和准确率高于单独形态学特征、高分辨率CT和PET/CT测量参数(p<0.001)。

临床应用与阅片要点

  • 对3厘米或更小的磨玻璃密度结节,可同时评估CT磨玻璃成分衰减值与SUV指数以辅助鉴别浸润性腺癌与浸润前病变及微浸润腺癌。
  • 联合高分辨率CT与PET/CT的敏感度和准确率高于单独形态学特征、高分辨率CT或PET/CT测量参数。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of this study is to evaluate high-resolution CT (HRCT) combined with PET/CT for preoperative differentiation of invasive adenocarcinoma (IAC) from preinvasive lesions and minimally invasive adenocarcinoma (MIA) (the combination of which is hereafter referred to as preinvasive-MIA) in lung adenocarcinoma manifesting as ground-glass opacity nodules (GGNs) 3 cm or smaller. MATERIALS AND METHODS. We retrospectively analyzed the data of patients with lung adenocarcinoma with GGNs that were 3 cm or smaller between November 2011 and November 2018. The HRCT and PET/CT parameters for GGNs were compared to differentiate between IAC and preinvasive-MIA. Qualitative and quantitative parameters were analyzed using univariate and multivariate logistic regression models. The diagnostic performance of different parameters was compared using ROC curves and the McNemar test. RESULTS. The study enrolled 89 patients (24 men and 65 women) with lung adenocarcinoma who had a mean (± SD) age of 60.1 ± 8.1 years (range, 36-78 years). The proportions of mixed GGN type, polygonal or irregular shape, lobulated or spiculated edge, and dilated, distorted, or cutoff bronchial sign were higher for IAC GGNs than for preinvasive-MIA GGNs, and the attenuation value of the ground-glass opacity component on CT (CTGGO), maximum standardized uptake value, and the standardized uptake value (SUV) index (i.e., the ratio of the tumor maximum SUV to the liver mean SUV) for IAC GGNs were also higher (p = 0.001-0.022). Logistic regression analyses showed that the CTGGO and SUV index were independent predictors for IAC GGNs. The accuracy of CTGGO in combination with the SUV index for predicting IAC was 81.4% on a per-GGN basis and 85.4% on a per-patient basis. The combined HRCT and PET/CT modality had higher sensitivity and accuracy than did morphologic features, HRCT, and PET/CT measurement parameters alone (p < 0.001). CONCLUSION. The combined HRCT and PET/CT modality is an effective method to preoperatively identify IAC in lung adenocarcinoma manifesting as GGNs 3 cm or smaller.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Niu R, Shao X, Shao X, et al. Lung Adenocarcinoma Manifesting as Ground-Glass Opacity Nodules 3 cm or Smaller: Evaluation With Combined High-Resolution CT and PET/CT Modality. AJR Am J Roentgenol. 2019. PMID: 31361533. doi:10.2214/AJR.19.21382

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。