磁共振成像评估开窗与完成型Fontan循环的血流分布,重点关注腹部血流
本研究用MRI测量39例Fontan循环患儿的胸腹部动静脉血流量,并与健康对照参考范围比较。完成型Fontan循环患儿心输出量及腹部血流降低,开窗型则因体肺侧支分流导致腹部血流降低;肠系膜上静脉及门静脉血流在完成型中降低更严重,肝动脉血流在开窗型降低而在完成型明显升高。
要点
- 完成型Fontan循环患儿心输出量及腹部血流较健康对照降低,肠系膜上静脉及门静脉血流降低更严重。
- 开窗型Fontan循环患儿心输出量正常,但腹部血流降低,主要因心输出量分流至体肺侧支。
- 完成型Fontan循环患儿肝动脉血流明显升高,开窗型则降低,Group 2表现为两种模式的混合。
核心结论
- Fontan循环与腹部血流降低相关:完成型Fontan循环归因于心输出量及门静脉回流降低,开窗型Fontan循环归因于心输出量分流至体肺侧支。
研究设计与样本
- 研究纳入39例Fontan循环患儿(女18例、男21例;平均年龄9.3岁,年龄范围3.3-17.0岁),用MRI测量胸部和腹部动脉及静脉的血流量,并与健康对照的参考范围比较。
关键影像表现/征象
- Group 1(开窗型Fontan循环,全身麻醉下MRI,15例,平均年龄5.9岁)心输出量3.92 ± 0.40 L/min/m²,与对照3.72 ± 0.69 L/min/m²相比无显著差异(p = 0.30)。
- Group 3(完成型Fontan循环,非全身麻醉下MRI,18例,平均年龄12.5岁)心输出量3.24 ± 0.71 L/min/m²,较对照3.96 ± 0.64 L/min/m²降低(p = 0.003)。
- Group 1腹部血流1.21 ± 0.28 L/min/m²,较对照2.37 ± 0.45 L/min/m²降低(p < 0.001);Group 3腹部血流1.89 ± 0.39 L/min/m²,较对照2.64 ± 0.38 L/min/m²降低(p < 0.001)。
- Group 1肠系膜上静脉及门静脉血流量与健康对照的比值分别为0.63和0.53,Group 3分别为0.26和0.37,Group 3降低更严重。
- Group 3肝动脉血流0.38 ± 0.22 L/min/m²,较对照-0.08 ± 0.29 L/min/m²明显升高(p < 0.0001);Group 2(完成型Fontan循环,全身麻醉下MRI,6例,平均年龄8.7岁)表现为Group 1和Group 3模式的混合。
临床应用与阅片要点
- 在Fontan循环患儿中,MRI可用于评估胸腹部动静脉的区域血流分布,辅助识别腹部血流降低及其机制。
- 开窗型Fontan循环患儿心输出量可正常,但腹部血流降低,需注意体肺侧支分流对心输出量的影响。
- 完成型Fontan循环患儿心输出量及门静脉回流降低,肠系膜上静脉及门静脉血流降低更严重,肝动脉血流代偿性升高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate the regional flow distribution in patients with Fontan circulation by using magnetic resonance imaging (MRI).
MATERIALS AND METHODS: We identified 39 children (18 females and 21 males; mean age, 9.3 years; age range, 3.3-17.0 years) with Fontan circulation in whom flow volumes across the thoracic and abdominal arteries and veins were measured by using MRI. The patients were divided into three groups: fenestrated Fontan circulation group with MRI performed under general anesthesia (GA) (Group 1, 15 patients; average age, 5.9 years), completed Fontan circulation group with MRI performed under GA (Group 2, 6 patients; average age, 8.7 years), and completed Fontan circulation group with MRI performed without GA (Group 3, 18 patients; average age, 12.5 years). The patient data were compared with the reference ranges in healthy controls.
RESULTS: In comparison with the controls, Group 1 showed normal cardiac output (3.92 ± 0.40 vs. 3.72 ± 0.69 L/min/m², p = 0.30), while Group 3 showed decreased cardiac output (3.24 ± 0.71 vs. 3.96 ± 0.64 L/min/m², p = 0.003). Groups 1 and 3 showed reduced abdominal flow (1.21 ± 0.28 vs. 2.37 ± 0.45 L/min/m², p < 0.001 and 1.89 ± 0.39 vs. 2.64 ± 0.38 L/min/m², p < 0.001, respectively), which was mainly due to the diversion of the cardiac output to the aortopulmonary collaterals in Group 1 and the reduced cardiac output in Group 3. Superior mesenteric and portal venous flows were more severely reduced in Group 3 than in Group 1 (ratios between the flow volumes of the patients and healthy controls was 0.26 and 0.37 in Group 3 and 0.63 and 0.53 in Group 1, respectively). Hepatic arterial flow was decreased in Group 1 (0.11 ± 0.22 vs. 0.34 ± 0.38 L/min/m², p = 0.04) and markedly increased in Group 3 (0.38 ± 0.22 vs. -0.08 ± 0.29 L/min/m², p < 0.0001). Group 2 showed a mixture of the patterns seen in Groups 1 and 3.
CONCLUSION: Fontan circulation is associated with reduced abdominal flow, which can be attributed to reduced cardiac output and portal venous return in completed Fontan circulation, and diversion of the cardiac output to the aortopulmonary collaterals in fenestrated Fontan circulation.