「暗血」双能CT血管造影用于胸主动脉壁成像
本研究纳入22例急性胸痛患者(11例女性,平均年龄61±20岁),共25次双层探测器非增强与增强CT检查,回顾性采用双材料分解法生成「暗血」图像,并与真实非增强CT比较。结果显示,暗血图像在正常主动脉段和壁内血肿段的壁-腔对比噪声比、诊断质量评分及管壁显示清晰度评分均高于真实非增强CT(均p<0.001)。作者结论认为,与真实非增强CT相比,暗血材料分解图可提升正常主动脉壁及壁内血肿评估的定量与定性图像质量。
要点
- 暗血图像由双能CT血管造影经双材料分解生成,第一材料取升主动脉感兴趣区内容物,第二材料为水。
- 正常主动脉段暗血图像诊断质量评分2.7±0.6,高于真实非增强CT的0.9±0.3(p<0.001)。
- 壁内血肿段暗血图像壁-腔对比噪声比4.0±1.0,高于真实非增强CT的0.3±0.2(p<0.001)。
核心结论
- 与真实非增强CT相比,暗血材料分解图可提升正常主动脉壁及壁内血肿评估的定量与定性图像质量。
研究设计与样本
- 回顾性研究,纳入22例急性胸痛患者(11例女性,平均年龄61±20岁),共25次双层探测器非增强与增强CT检查。
- CT血管造影图像经双材料分解处理,第一材料定义为每例患者升主动脉感兴趣区内容物,第二材料为水,生成「暗血」图像。
- 由两名独立放射科医师评估暗血图像与真实非增强CT图像的壁-腔对比噪声比、主动脉壁增厚诊断质量及内外血管壁显示清晰度。
关键影像表现/征象
- 正常主动脉段诊断质量评分在真实非增强CT为0.9±0.3,暗血图像为2.7±0.6(p<0.001)。
- 正常主动脉段管壁显示清晰度评分在真实非增强CT为0.7±0.5,暗血图像为1.8±0.3(p<0.001)。
- 壁内血肿段诊断质量评分在真实非增强CT为1.7±0.5,暗血图像为2.4±0.6(p<0.001)。
- 壁内血肿段管壁显示清晰度评分在真实非增强CT为0.7±0.7,暗血图像为1.8±0.3(p<0.001)。
- 正常主动脉段壁-腔对比噪声比在真实非增强CT为0.3±0.2,暗血图像为2.8±0.9(p<0.001);壁内血肿段在真实非增强CT为0.3±0.2,暗血图像为4.0±1.0(p<0.001)。
诊断标准与关键数值
- 暗血图像通过双材料分解生成:第一材料为每例患者升主动脉感兴趣区内容物,第二材料为水。
- 评估指标包括壁-腔对比噪声比、主动脉壁增厚诊断质量评分及内外血管壁显示清晰度评分。
临床应用与阅片要点
- 暗血图像可提高正常主动脉壁与壁内血肿的壁-腔对比噪声比及管壁显示清晰度,有助于评估血管壁结构。
- 作者指出,该双能CT材料分解方法可能利用CT高空间分辨率,在其他应用中改善对比分辨率。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the capability of a newly developed material decomposition method from contrast-enhanced dual-energy CT images, aiming to better visualize the aortic wall and aortic intramural hematoma (IMH), compared with true non-contrast (TNC) CT.
MATERIALS AND METHODS: Twenty-two patients (11 women; mean age, 61 ± 20 years) with acute chest pain underwent 25 dual-layer non-contrast and contrast-enhanced CT. CT-angiography images were retrospectively processed using two-material decomposition analysis, where we defined the first material as the content of a region of interest placed in the ascending aorta for each patient, and the second material as water. Two independent radiologists assessed the images from the second material termed "dark-blood" images and the TNC images regarding contrast-to-noise ratio (CNR) between the wall and the lumen, diagnostic quality regarding the presence of aortic wall thickening, and the inner/outer vessel wall conspicuity.
RESULTS: Diagnostic quality scores in normal aortic segments were 0.9 ± 0.3 and 2.7 ± 0.6 (p < 0.001) and wall conspicuity scores were 0.7 ± 0.5 and 1.8 ± 0.3 (p < 0.001) on TNC and dark-blood images, respectively. In aortic segments with IMH, diagnostic quality scores were 1.7 ± 0.5 and 2.4 ± 0.6 (p < 0.001) and wall conspicuity scores were 0.7 ± 0.7 and 1.8 ± 0.3 (p < 0.001) on TNC and dark-blood images, respectively. In normal aortic segments, CNRs were 0.3 ± 0.2 and 2.8 ± 0.9 on TNC and dark-blood images, respectively (p < 0.001). In aortic segments with IMH, CNRs were 0.3 ± 0.2 and 4.0 ± 1.0 on TNC and dark-blood images, respectively (p < 0.001).
CONCLUSIONS: Compared with true non-contrast CT, dark-blood material decomposition maps enhance quantitative and qualitative image quality for the assessment of normal aortic wall and IMH.
KEY POINTS: • Current dual-energy CT-angiography provides virtual non-contrast and bright-blood images. • Dark-blood images represent a new way to assess the vascular wall structure with dual-energy CT and can improve the lumen-to-wall contrast compared with true non-contrast CT. • This dual-energy CT material decomposition method is likely to improve contrast resolution in other applications as well, taking advantage of the high spatial resolution of CT.
引用
- Rotzinger DC, Si-Mohamed SA, Shapira N, et al. "Dark-blood" dual-energy computed tomography angiography for thoracic aortic wall imaging. Eur Radiol. 2019. PMID: 31332557. doi:10.1007/s00330-019-06336-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。