文献速递胸部介入CT

定量CT分析裂隙完整性在支气管镜肺减容术中的临床价值:CT与Chartis™的比较

Clinical Utility of Quantitative CT Analysis for Fissure Completeness in Bronchoscopic Lung Volume Reduction: Comparison between CT and Chartis™.
PubMed 文献 · Korean J Radiol · 2019-01-01

本研究纳入69例拟行支气管镜肺减容术患者,用容积CT定量分析裂隙完整性并与Chartis™侧支通气检测比较。视觉与定量分析在5%缺损标准下一致性良好;裂隙不完整者Chartis™侧支通气阳性率高于裂隙完整者;部分裂隙缺损较大但Chartis™阴性的患者仍可实现靶肺叶体积减少。

要点

  • 裂隙不完整者Chartis™侧支通气阳性率高于裂隙完整者。
  • 裂隙缺损大小不影响侧支通气阳性率。
  • 部分裂隙缺损较大但Chartis™阴性的患者仍可实现靶肺叶体积减少。

核心结论

  • CT定量分析显示裂隙不完整增加Chartis™侧支通气阳性概率,但缺损大小不影响总体阳性率;部分裂隙缺损相对较大但Chartis™阴性的患者仍可实现靶肺叶体积减少。

研究设计与样本

  • 研究纳入69例拟评估支气管镜肺减容术适应证并接受CT检查的患者,平均年龄70.9±6.6岁,男性66例(95.7%);由经验丰富的胸部放射科医师独立在容积CT图像上判断裂隙完整性,以Chartis™系统(Pulmonox Inc.)检测侧支通气作为参照。

关键影像表现/征象

  • 视觉分析与定量分析在5%缺损标准下显示良好一致性。
  • Chartis™评估共129个肺叶;CT上裂隙完整的56个肺叶中11个(19.6%)侧支通气阳性,裂隙不完整的49个肺叶中40个(81.6%)侧支通气阳性。
  • 裂隙缺损大小不影响侧支通气阳性率。

诊断标准与关键数值

  • 以Chartis™系统检测侧支通气作为参照,CT上裂隙完整者侧支通气阳性11/56(19.6%),裂隙不完整者阳性40/49(81.6%)。
  • 视觉与定量分析在5%缺损标准下一致性良好。

临床应用与阅片要点

  • 阅片时可对容积CT图像上的肺裂完整性进行定量分析,以辅助评估侧支通气可能性。
  • 裂隙不完整提示Chartis™侧支通气阳性的概率较高,但缺损大小不影响总体阳性率。
  • 部分裂隙缺损相对较大但Chartis™阴性的患者仍可实现靶肺叶体积减少。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The absence of collateral ventilation (CV) is crucial for effective bronchoscopic lung volume reduction (BLVR) with an endobronchial valve. Here, we assessed whether CT can predict the Chartis™ results.

MATERIALS AND METHODS: This study included 69 patients (mean age: 70.9 ± 6.6 years; 66 [95.7%] males) who had undergone CT to assess BLVR eligibility. The Chartis™ system (Pulmonox Inc.) was used to check CV. Experienced thoracic radiologists independently determined the completeness of fissures on volumetric CT images.

RESULTS: The comparison between the visual and quantitative analyses revealed that 5% defect criterion showed good agreement. The Chartis™ assessment was performed for 129 lobes; 11 (19.6%) of 56 lobes with complete fissures on CT showed positive CV, while this rate was significantly higher (40 of 49 lobes, i.e., 81.6%) for lobes with incomplete fissures. The size of the fissure defect did not affect the rate of CV. Of the patients who underwent BLVR, 22 of 24 patients (91.7%) with complete fissures and three of four patients with incomplete fissures (75%) achieved target lobe volume reduction (TLVR).

CONCLUSION: The quantitative analysis of fissure shows that incomplete fissures increased the probability of CV on Chartis™, while the defect size did not affect the overall rates. TLVR could be achieved even in some patients with relatively large fissure defect, if they showed negative CV on Chartis™.

来源:Korean J Radiol,查看原文。版权归原作者所有。