多站点学术机构颞骨CT平面的标准化
该研究在单一多站点机构评估技师教育干预加后处理或自动后处理算法能否使颞骨CT重建平面统一参考外侧半规管。结果显示技师重建图像与外侧半规管平面的误差角中位数4.9°,显著低于采集平面图像的14.6°和自动重建图像的13.8°,但作者认为基于本机构对标准化平面的偏好,技师重建仍属必要。
要点
- 技师重建的颞骨CT图像与外侧半规管平面误差角中位数4.9°,显著低于采集平面图像的14.6°。
- 技师重建图像中轴位准确率87%、冠状位81%,错误多发生于院外、住院和急诊扫描仪。
- 自动重建图像误差角中位数13.8°,显著低于采集平面图像但高于技师重建图像。
核心结论
- 技师和自动重建颞骨图像均较采集平面图像显著减少成像平面方差,但基于本机构对参考外侧半规管标准化平面的偏好,技师重建仍属必要。
研究设计与样本
- 在单一多站点机构的12台CT扫描仪操作台张贴小视野图像参考外侧半规管平面重建的说明,并向65名CT技师发送邮件;同时生成自动重建图像,测量技师重建和自动重建轴位图像平面与外侧半规管平面的角度。
诊断标准与关键数值
- 技师重建轴位准确率87%,冠状位准确率81%,随时间有改善趋势。
- 80%的错误重建图像发生于院外、住院和急诊扫描仪。
- 技师重建图像误差角中位数4.9°,采集平面图像中位数14.6°(P=3×10⁻¹⁴),自动重建图像中位数13.8°(P=9×10⁻¹³)。
- 角度误差方差齐性:技师重建图像P=3×10⁻⁸、自动重建图像P=1×10⁻⁵,均较采集平面图像更 homogeneous。
临床应用与阅片要点
- 作者认为基于本机构对参考外侧半规管标准化平面的偏好,技师重建仍属必要。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Variable head positioning in the CT gantry results in variable and inconsistent temporal bone imaging planes. Our aim was to evaluate whether an automated postprocessing algorithm or an educational intervention with postprocessing by a technologist could result in consistent temporal bone image reformations into planes referenced to the lateral semicircular canal.
MATERIALS AND METHODS: Instructions to reformat small-FOV images in planes referenced to the lateral semicircular canal were posted at 12 CT scanner consoles and e-mailed to 65 CT technologists at a single multisite institution. Automated reformatted images were also produced. The angles between the technologist- and automated-reformatted axial image planes and lateral semicircular canal planes were measured. Group differences were calculated with Mann-Whitney-Wilcoxon tests. Differences in homogeneity of variances were calculated with Fligner-Killeen tests.
RESULTS: Two hundred ten temporal bones were imaged in 4 months following the intervention. Reformats by technologists were accurate in 87% of the axial and 81% of the coronal planes, with a trend toward improvement with time. Eighty percent of incorrectly reformatted images occurred at off-site, inpatient, and emergency department scanners. The error angle was significantly lower for technologist-reformatted images (median, 4.9°) than for acquisition plane images (median, 14.6°; P = 3 × 10-14) or automated-reformatted images (median, 13.8°; P = 9 × 10-13). The angle error variance was significantly more homogeneous for technologist-reformatted images (P = 3 × 10-8) and automated-reformatted images (P = 1 × 10-5) than for acquisition plane images.
CONCLUSIONS: Both technologist and automated reformatting of temporal bone images resulted in significantly less imaging plane variance compared with images reformatted in the acquisition plane, but reformatting by technologists remains necessary at our institution given our preference for standardized planes referencing the lateral semicircular canals.
引用
- Guenette JP, Hsu L, Czajkowski B, et al. Standardization of Temporal Bone CT Planes across a Multisite Academic Institution. AJNR Am J Neuroradiol. 2019. PMID: 31272961. doi:10.3174/ajnr.A6111
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。