健康对照者脑表观扩散系数分析:单次激发回波平面成像与读出分段回波平面成像的比较研究
研究纳入30名健康受试者,在3T磁共振上比较单次激发回波平面成像(ss-EPI)与读出分段回波平面成像(rs-EPI)所测脑灰质、白质和脑脊液的表观扩散系数(ADC)。结果显示全脑和脑脊液ADC高度相关一致,而灰质和白质ADC差异显著且一致性差;作者认为不同采集方法所得ADC应谨慎解读,尤其是个体内比较时。
要点
- 全脑和脑脊液ADC在ss-EPI与rs-EPI间高度相关一致(r>0.988)。
- 灰质和白质ADC在两种采集方法间差异显著(p<0.001)。
- 白质ADC相关性最低(r=0.894),白质和灰质一致性差。
核心结论
- rs-EPI与ss-EPI的全脑和脑脊液ADC高度相关且一致,但白质和灰质ADC差异显著、变异性大,反映不同区域微环境所致的脑实质不均匀性;不同采集方法的ADC应谨慎解读,尤其是个体内比较时。
研究设计与样本
- 采用3T磁共振扫描仪采集30名健康受试者的T2加权图像、rs-EPI和ss-EPI,将T2加权图像配准至rs-EPI和ss-EPI并分割为灰质、白质和脑脊液以生成掩膜模板,再用模板分割两种采集的ADC图。
诊断标准与关键数值
- rs-EPI与ss-EPI的ADC在灰质差异显著(p<0.001)、在白质差异显著(p<0.001)。
- 全脑和脑脊液ADC高度一致且相关(r>0.988;p<0.001)。
- 白质ADC相关性最低(r=0.894;p<0.001),白质和灰质ADC一致性差。
- 各脑区Pearson相关方程:灰质y=1.1x-59.4,白质y=1.45x-255,脑脊液y=0.98x-63.5,其中x和y分别代表rs-EPI和ss-EPI的ADC。
临床应用与阅片要点
- 作者认为不同采集方法的ADC应谨慎解读,尤其是个体内比较时。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare apparent diffusion coefficients (ADCs) of brain segments by using two diffusion-weighted imaging acquisition modes, single-shot echo-planar imaging (ss-EPI) and read-out-segmented echo-planar imaging (rs-EPI), and to assess their correlation and agreement in healthy controls.
MATERIALS AND METHODS: T2-weighted (T2W) images, rs-EPI, and ss-EPI of 30 healthy subjects were acquired using a 3T magnetic resonance scanner. The T2W images were co-registered to the rs-EPI and ss-EPI, which were then segmented into the gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF) to generate masking templates. ADC maps of rs-EPI and ss-EPI were also segmented into the GM, WM, and CSF by using the generated templates. ADCs of rs-EPI and ss-EPI were compared using Student's t tests and correlated using Pearson's correlation coefficients. Bland-Altman plots were used to assess the agreement between acquisitions.
RESULTS: ADCs of rs-EPI and ss-EPI were significantly different in the GM (p < 0.001) and WM (p < 0.001). ADCs showed high agreement and correlation in the whole brain and CSF (r > 0.988; p < 0.001). ADC of the WM showed the least correlation (r = 0.894; p < 0.001), and ADCs of the WM and GM showed poor agreement. Pearson's correlation equations for each brain segment were y = 1.1x - 59.4 (GM), y = 1.45x - 255 (WM), and y = 0.98x - 63.5 (CSF), where x and y indicated ADCs of rs-EPI and ss-EPI, respectively.
CONCLUSION: While ADCs of rs-EPI and ss-EPI showed high correlation and agreement in the whole brain and CSF, ADCs of the WM and GM showed significant differences and large variability, reflecting brain parenchymal inhomogeneity due to different regional microenvironments. ADCs of different acquisition methods should be interpreted carefully, especially in intra-individual comparisons.
引用
- Choi Y, Hwang EJ, Nam Y, et al. Analysis of Apparent Diffusion Coefficients of the Brain in Healthy Controls: A Comparison Study between Single-Shot Echo-Planar Imaging and Read-out-Segmented Echo-Planar Imaging. Korean J Radiol. 2019. PMID: 31270977. doi:10.3348/kjr.2018.0899