文献速递神经儿科影像MR

评估婴儿脑组织对比度及检测白质损伤:合成相位敏感反转恢复序列的对比研究

Evaluating Tissue Contrast and Detecting White Matter Injury in the Infant Brain: A Comparison Study of Synthetic Phase-Sensitive Inversion Recovery.
PubMed 文献 · AJNR Am J Neuroradiol · 2019-07-25

该研究比较了91例婴儿的3D T1加权快速扰相梯度回波、合成T1WI与合成相位敏感反转恢复序列的图像质量。合成相位敏感反转恢复序列在未髓鞘化白质与髓鞘化白质对比度、灰白质分化和髓鞘化程度方面更优,但检测点状白质损伤的数量少于快速扰相梯度回波序列。

要点

  • 合成相位敏感反转恢复序列可提高婴儿脑MR图像的组织对比度和图像质量。
  • 评估点状白质损伤时,合成相位敏感反转恢复序列检测的病灶数少于3D快速扰相梯度回波序列。
  • 合成相位敏感反转恢复序列在显示灰白质分化和小脑脚髓鞘化程度方面优于合成T1WI。

核心结论

  • 合成相位敏感反转恢复序列有潜力改善婴儿脑MR成像的组织对比度和图像质量,但与3D快速扰相梯度回波成像相比,其在评估点状白质损伤方面价值有限。

研究设计与样本

  • 对比研究,纳入91例婴儿,比较3D T1加权快速扰相梯度回波、合成T1WI和合成相位敏感反转恢复序列的脑MR图像。

关键影像表现/征象

  • 未髓鞘化白质与髓鞘化白质对比度在合成相位敏感反转恢复序列高于快速扰相梯度回波序列或合成T1WI(P < .001)。
  • 合成相位敏感反转恢复序列较合成T1WI显示更高的灰白质分化(P < .001)和小脑脚髓鞘化程度(P < .001)。
  • 点状白质损伤病灶数在合成相位敏感反转恢复序列为1.2 ± 3.2,少于快速扰相梯度回波序列的3.4 ± 3.6(P = .001)。

局限性

  • 作者指出需注意合成相位敏感反转恢复序列在评估点状白质损伤方面价值有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Synthetic MR imaging enables the acquisition of phase-sensitive inversion recovery images. The aim of this study was to compare the image quality of synthetic phase-sensitive inversion recovery with that of other sequences in infants.

MATERIALS AND METHODS: Brain MR imaging with 3D T1-weighted fast-spoiled gradient recalled, synthetic T1WI, and synthetic phase-sensitive inversion recovery of 91 infants was compared. Contrast between unmyelinated WM and myelinated WM and between unmyelinated WM and cortical GM was calculated. Qualitative evaluation of image quality and myelination degree was performed. In infants with punctate white matter injuries, the number of lesions was compared.

RESULTS: The contrast between unmyelinated WM and myelinated WM was higher in synthetic phase-sensitive inversion recovery compared with fast-spoiled gradient recalled or synthetic T1WI (P < .001). Compared with synthetic T1WI, synthetic phase-sensitive inversion recovery showed higher gray-white matter differentiation (P < .001) and myelination degree in the cerebellar peduncle (P < .001). The number of detected punctate white matter injuries decreased with synthetic phase-sensitive inversion recovery compared with fast-spoiled gradient recalled sequences (1.2 ± 3.2 versus 3.4 ± 3.6, P = .001).

CONCLUSIONS: Synthetic phase-sensitive inversion recovery has the potential to improve tissue contrast and image quality in the brain MR imaging of infants. However, we have to be aware that synthetic phase-sensitive inversion recovery has limited value when assessing punctate white matter injuries compared with 3D fast-spoiled gradient recalled imaging.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。