文献速递儿科影像神经USMR

额枕角比与额颞角比:婴儿脑室扩大的头颅超声衍生指数与MRI及脑室体积的比较与验证

Frontal Occipital and Frontal Temporal Horn Ratios: Comparison and Validation of Head Ultrasound-Derived Indexes With MRI and Ventricular Volumes in Infantile Ventriculomegaly.
PubMed 文献 · AJR Am J Roentgenol · 2019-07-16

回顾性纳入2014至2017年90例(100组检查)≤6月龄矫正胎龄的脑室扩大婴儿,比较超声与MRI测量的额枕角比(FOHR)和额颞角比(FTHR)。超声与MRI的FOHR偏倚0.05(95%CI -0.04~0.14),FTHR偏倚0.03(95%CI -0.06~0.13);观察者间r=0.86~0.96,与MRI脑室体积比r=0.79~0.87。结论认为超声衍生的FOHR和FTHR是临床随访婴儿脑室扩大的可靠指标。

要点

  • 超声与MRI测量的FOHR和FTHR一致性优秀,偏倚分别为0.05和0.03。
  • FOHR和FTHR在超声或MRI上的观察者间一致性良好至优秀(r=0.86~0.96)。
  • 超声与MRI衍生的FOHR和FTHR与MRI脑室颅内体积比相关性良好(r=0.79~0.87)。

核心结论

  • 超声获得的FOHR和FTHR在脑室扩大婴儿中观察者间一致性优秀,与MRI线性比值一致,并与MRI脑室体积相关,是临床随访婴儿脑室扩大的可靠指标。

研究设计与样本

  • 回顾性研究,纳入2014至2017年90例年龄≤6个月矫正胎龄的脑室扩大婴儿,共100组在3天内完成的超声与MRI检查;由两名儿科放射科医师独立测量超声FOHR和FTHR,两名儿科神经放射科医师测量MRI对应值,并以MRI为参考标准分割脑室和脑体积计算脑室颅内体积比。

诊断标准与关键数值

  • 超声与MRI的FOHR偏倚0.05(95%CI -0.04~0.14),FTHR偏倚0.03(95%CI -0.06~0.13);FOHR和FTHR在超声或MRI上的观察者间一致性r=0.86~0.96;脑室颅内体积比与超声及MRI衍生的FOHR和FTHR相关性r=0.79~0.87。

临床应用与阅片要点

  • 作者认为超声衍生的FOHR和FTHR是临床随访婴儿脑室扩大的可靠指标。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of our study was to assess whether linear ventricular dimensions-specifically, the frontal occipital horn ratio (FOHR) and frontal temporal horn ratio (FTHR) obtained from ultrasound (US)-are reliable measures of ventriculomegaly in infants. Our hypothesis was that these US measures would show good correlation with linear ventricular indexes and ventricular volumes obtained from MRI. MATERIALS AND METHODS. We retrospectively identified 90 infants (age ≤ 6 months corrected gestational age) with ventriculomegaly from 2014 to 2017 who had a total of 100 sets of US and MRI studies performed in a 3-day period. FOHR and FTHR were independently measured on US and MRI by two pediatric radiologists and two pediatric neuroradiologists, respectively. Ventricular and brain volumes were segmented from the MR images, and the ventricle-to-intracranial volume ratio was calculated. MRI served as the reference standard. Intraclass correlation coefficients and Bland-Altman analyses were generated to evaluate interobserver and US-MRI concordance. We assessed correlation of the FOHR and FTHR with the ventricle-to-intracranial volume ratio. RESULTS. Bland-Altman plots of the FOHR and FTHR between US and MRI showed excellent concordance with a bias of 0.05 (95% CI, -0.04 to 0.14) and 0.03 (95% CI, -0.06 to 0.13), respectively. There was good-to-excellent interobserver concordance for FOHR and FTHR on head US or MRI (r = 0.86-0.96). There was good correlation between ventricle-to-intracranial volume ratios and US- and MRI-derived FOHRs and FTHRs (r = 0.79-0.87). CONCLUSION. FOHR and FTHR obtained from US in infants with ventriculomegaly have excellent interobserver concordance, are concordant with MRI-derived linear ratios, and correlate with MRI-derived ventricular volumes. Therefore, US-derived FOHR and FTHR are reliable indexes for clinical follow-up of infantile ventriculomegaly.