酰胺质子转移加权信号在脑内的可重复性:按临床状况和解剖位置分析
研究纳入19名健康者、15名胶质瘤患者和12名急性卒中患者,在3T磁共振上采集酰胺质子转移加权(APTw)MRI数据,评估临床状况、扫描次数和解剖位置对可重复性的影响。结果显示幕上区域APTw信号可重复性优秀,幕下区域因B0不均匀性和磁化率效应导致可重复性差,作者认为幕下区域不宜用于纵向评估。
要点
- 幕上区域APTw信号在健康脑、胶质瘤和卒中病灶中均显示优秀的组内和组间可重复性。
- 幕下区域APTw信号可重复性差,ICC仅0.44,受B0不均匀性和磁化率影响。
- 幕上平均APTw信号0.49%显著低于幕下1.09%(p<0.001)。
核心结论
- APTw信号在幕上位置可重复性优秀,在幕下位置因严重B0不均匀性和磁化率影响MTR不对称性而可重复性差。
研究设计与样本
- 研究采集三组APTw MRI数据,包括两次组内扫描和一次组间扫描,对象为19名健康者、15名胶质瘤患者和12名急性卒中成人 participant(平均年龄分别为53.8、54.6和68.5岁),使用3T MR扫描仪。
关键影像表现/征象
- 幕上位置平均APTw信号为0.49%(95%CI 0.38-0.61),幕下位置为1.09%(95%CI 0.98-1.20),两者差异显著(p<0.001)。
诊断标准与关键数值
- 胶质瘤组ICC为0.96(95%CI 0.91-0.99),wCV为16.1(95%CI 12.6-21.3)。
- 卒中组ICC为0.93(95%CI 0.82-0.98),wCV为15.0(95%CI 11.4-20.6)。
- 健康脑组ICC为0.84(95%CI 0.72-0.91),wCV为34.0(95%CI 28.7-41.0)。
- 幕上位置ICC为0.85(95%CI 0.68-0.94),wCV为27.4(95%CI 21.8-35.6)。
- 幕下位置ICC为0.44(95%CI -0.18至0.76),wCV为32.7(95%CI 25.9-42.9)。
临床应用与阅片要点
- 作者指出,鉴于幕下位置可重复性差,不推荐在幕下位置使用APTw MRI进行纵向评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate whether clinical condition, imaging session, and locations affect repeatability of amide proton transfer-weighted (APTw) magnetic resonance imaging (MRI) in the brain.
MATERIALS AND METHODS: Three APTw MRI data sets were acquired, involving two intrasession scans and one intersession scan for 19 healthy, 15 glioma, and 12 acute stroke adult participants (mean age 53.8, 54.6, and 68.5, respectively) on a 3T MR scanner. The mean APTw signals from five locations in healthy brain (supratentorial and infratentorial locations) and from entire tumor and stroke lesions (supratentorial location) were calculated. The within-subject coefficient of variation (wCV) and intraclass correlation coefficient (ICC) were calculated for each clinical conditions, image sessions, and anatomic locations. Differences in APTw signals between sessions were analyzed using repeated-measures analysis of variance.
RESULTS: The ICC and wCV were 0.96 (95% confidence interval [CI], 0.91-0.99) and 16.1 (12.6-21.3) in glioma, 0.93 (0.82-0.98) and 15.0 (11.4-20.6) in stroke, and 0.84 (0.72-0.91) and 34.0 (28.7-41.0) in healthy brain. There were no significant differences in APTw signal between three sessions, irrespective of disease condition and location. The ICC and wCV were 0.85 (0.68-0.94) and 27.4 (21.8-35.6) in supratentorial, and 0.44 (- 0.18 to 0.76) and 32.7 (25.9 to 42.9) in infratentorial locations. There were significant differences in APTw signal between supra- (mean, 0.49%; 95% CI, 0.38-0.61) and infratentorial locations (1.09%, 0.98-1.20; p < 0.001).
CONCLUSION: The repeatability of APTw signal was excellent in supratentorial locations, while it was poor in infratentorial locations due to severe B0 inhomogeneity and susceptibility which affects MTR asymmetry.
KEY POINTS: • In supratentorial locations, APTw MRI showed excellent intrasession and intersession repeatability in brains of healthy controls and patients with glioma, as well as in stroke-affected regions. • APTw MRI showed excellent repeatability in supratentorial locations, but poor repeatability in infratentorial locations. • Considering poor repeatability in the infratentorial locations, the use of APTw MRI in longitudinal assessment in infratentorial locations is not indicated.
引用
- Lee JB, Park JE, Jung SC, et al. Repeatability of amide proton transfer-weighted signals in the brain according to clinical condition and anatomical location. Eur Radiol. 2019. PMID: 31338651. doi:10.1007/s00330-019-06285-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。