时间最大强度投影CT血管成像评估急性缺血性卒中患者颅内血管状态:初步研究
回顾性分析29例急性缺血性卒中患者的一站式CTA-CT灌注扫描数据,比较时间最大强度投影CTA(t-MIP CTA)与单期CTA(sCTA)在评估侧支循环和预测预后中的价值。t-MIP CTA噪声更低、血管衰减更高,侧支状态与改良Rankin量表评分及最终梗死体积的负相关性更强,预测预后的AUC为0.956,优于sCTA的0.824。
要点
- t-MIP CTA较sCTA噪声更低、血管信噪比和对比噪声比更高(均p<0.001)。
- t-MIP CTA侧支状态与改良Rankin量表评分(r=-0.709)及梗死体积(r=-0.716)负相关。
- t-MIP CTA预测预后AUC 0.956,敏感度0.917、特异度0.941,优于sCTA(AUC 0.824)。
核心结论
- 与sCTA相比,t-MIP图像显示颅内血管质量更高,MIP可更准确显示血管闭塞和评估侧支循环,推测t-MIP能更精确预测预后。
研究设计与样本
- 回顾性研究,纳入29例接受一站式CTA-CT灌注扫描的急性缺血性卒中患者,利用CT灌注扫描数据生成sCTA和t-MIP CTA,比较两组图像质量和侧支循环,并分析侧支状态与临床预后及梗死体积的相关性。
关键影像表现/征象
- t-MIP CTA噪声水平显著低于sCTA(p<0.001)。
- t-MIP CTA血管衰减(信噪比和对比噪声比)均高于sCTA(均p<0.001)。
- 所有图像均显示良好诊断质量。
诊断标准与关键数值
- t-MIP CTA侧支状态与改良Rankin量表评分负相关(r=-0.709,p<0.001),sCTA为r=-0.551,p=0.024。
- t-MIP CTA侧支状态与最终梗死体积负相关(r=-0.716,p=0.001),sCTA为r=-0.629,p=0.003。
- t-MIP CTA预测预后:AUC 0.956,敏感度0.917,特异度0.941,p<0.001。
- sCTA预测预后:AUC 0.824,敏感度0.500,特异度0.941,p=0.003。
临床应用与阅片要点
- t-MIP CTA可更准确显示颅内血管闭塞和评估侧支循环,图像质量优于sCTA。
- 作者推测t-MIP能更精确预测预后。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To describe the application of time maximum intensity projection CTA (t-MIP CTA) in acute ischemic stroke and compare t-MIP CTA and single-phase CTA (sCTA) in assessing collateral circulation and predicting prognosis.
MATERIALS AND METHODS: Twenty-nine acute ischemic stroke patients who underwent one-stop CT angiography (CTA)-CT perfusion scan were reviewed retrospectively. sCTA and t-MIP CTA were developed by CT perfusion scanning data. Image quality and collateral circulation were compared between the sCTA and t-MIP CTA groups. CT attenuation values, image noise, signal to noise , contrast to noise, and subjective image quality were obtained and compared between these two groups. The correlations of clinical prognosis and infarct volume with collateral status on t-MIP CTA and sCTA were analyzed, separately. Receiver operating characteristic curve was used to reveal the sensitivity and specificity of t-MIP CTA and sCTA in predicting outcome.
RESULTS: All images exhibited good quality for diagnosis. In objective evaluation, the noise level of t-MIP CTA was significantly lower than that of sCTA (p < 0.001). Vascular attenuation (signal to noise and contrast to noise) of t-MIP were higher than those of sCTA (all, p < 0.001). The collateral status on t-MIP CTA and sCTA were both negatively correlated with modified Rankin Scale scores (t-MIP CTA, r = -0.709, p < 0.001; sCTA, r = -0.551, p = 0.024) and the final infarction volume (t-MIP CTA, r = -0.716, p = 0.001; sCTA, r = -0.629, p = 0.003). t-MIP CTA was better for predicting prognosis (AUC, 0.956; sensitivity, 0.917; specificity, 0.941; p < 0.001) than sCTA (AUC, 0.824; sensitivity, 0.500; specificity, 0.941; p = 0.003).
CONCLUSION: In comparison with sCTA, t-MIP images showed higher image quality of intracranial vascularity and MIP could reveal vascular occlusion and evaluate collateral circulation more accurately. It was speculated that t-MIP could predict the prognosis more precisely.
引用
- Cao R, Jiang Y, Lu J, et al. Evaluation of Intracranial Vascular Status in Patients with Acute Ischemic Stroke by Time Maximum Intensity Projection CT Angiography: A Preliminary Study. Acad Radiol. 2019. PMID: 31324580. doi:10.1016/j.acra.2019.06.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。