不同器官的压缩感知MRI:是否已可用于临床日常实践?
该研究在107例患者中比较了压缩感知(加速30%至60%)与传统MRI序列在10种不同临床应用中的图像质量与伪影敏感性,共120次比较。结果显示除肘部序列外,各序列图像质量与伪影无统计学显著差异,诊断发现相似,压缩感知序列已可用于临床日常实践,但肘部应用需降低加速因子。
要点
- 压缩感知序列使扫描时间缩短至少30%,图像质量仅有轻微损失,诊断发现无变化。
- 除肘部压缩感知序列外,各序列图像质量与伪影与传统序列无统计学显著差异。
- 压缩感知加速因子需针对每个器官和序列单独调整,以保证图像质量。
核心结论
- 所评估的压缩感知序列已可用于临床日常实践,但肘部应用需要更低的加速因子;压缩感知因子应针对每个器官和序列进行调整,本研究评估的应用中实现了30%至60%的加速,对临床工作流程有显著影响。
研究设计与样本
- 研究在107例患者中于10种不同临床应用(从脑到膝)中执行压缩感知(加速30%至60%)与传统MRI序列,共产生120次比较;读者对技术不知情,进行定量(对比噪声比或心脏电影的功能测量)和定性(图像质量、伪影、诊断发现和偏好)图像分析。
关键影像表现/征象
- 除心脏电影压缩感知序列对其中一位读者以及腕部3D质子密度加权压缩感知序列因采集时间缩短而显示更少运动伪影外,各序列图像质量或伪影无统计学显著差异。
- 肘部压缩感知序列的对比噪声比更低,但在所有其他应用中无统计学显著差异。
- 除四例因运动伪影损坏传统或压缩感知序列外,所有比较中传统与压缩感知序列的诊断发现相似。
临床应用与阅片要点
- 所评估的压缩感知序列已可用于临床日常实践,但肘部应用需要更低的加速因子。
- 压缩感知因子应针对每个器官和序列进行调整,以获得良好的图像质量。
- 本研究评估的应用中实现了30%至60%的加速,对临床工作流程有显著影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim was to evaluate the image quality and sensitivity to artifacts of compressed sensing (CS) acceleration technique, applied to 3D or breath-hold sequences in different clinical applications from brain to knee.
METHODS: CS with an acceleration from 30 to 60% and conventional MRI sequences were performed in 10 different applications in 107 patients, leading to 120 comparisons. Readers were blinded to the technique for quantitative (contrast-to-noise ratio or functional measurements for cardiac cine) and qualitative (image quality, artifacts, diagnostic findings, and preference) image analyses.
RESULTS: No statistically significant difference in image quality or artifacts was found for each sequence except for the cardiac cine CS for one of both readers and for the wrist 3D proton density (PD)-weighted CS sequence which showed less motion artifacts due to the reduced acquisition time. The contrast-to-noise ratio was lower for the elbow CS sequence but not statistically different in all other applications. Diagnostic findings were similar between conventional and CS sequence for all the comparisons except for four cases where motion artifacts corrupted either the conventional or the CS sequence.
CONCLUSIONS: The evaluated CS sequences are ready to be used in clinical daily practice except for the elbow application which requires a lower acceleration. The CS factor should be tuned for each organ and sequence to obtain good image quality. It leads to 30% to 60% acceleration in the applications evaluated in this study which has a significant impact on clinical workflow.
KEY POINTS: • Clinical implementation of compressed sensing (CS) reduced scan times of at least 30% with only minor penalty in image quality and no change in diagnostic findings. • The CS acceleration factor has to be tuned separately for each organ and sequence to guarantee similar image quality than conventional acquisition. • At least 30% and up to 60% acceleration is feasible in specific sequences in clinical routine.
引用
- Delattre BMA, Boudabbous S, Hansen C, et al. Compressed sensing MRI of different organs: ready for clinical daily practice? Eur Radiol. 2019. PMID: 31264014. doi:10.1007/s00330-019-06319-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。