文献速递神经CTMR

诊断性神经放射学中感知错误与解读错误的危险因素

Risk Factors for Perceptual-versus-Interpretative Errors in Diagnostic Neuroradiology.
PubMed 文献 · AJNR Am J Neuroradiol · 2019-07-11

该研究对254例诊断性神经放射学临床错误病例进行分类,区分感知错误与解读错误,并分析影像技术、判读医师经验、解剖部位、疾病病因、时间等因素。结果显示感知错误占74.8%(190例),解读错误占25.2%(64例);经验≤5年的神经放射学主治医师发生解读错误的比值比为2.09(95%CI 1.05-4.15,P=0.04),MR较CT更易发生解读错误(OR=2.10,95%CI 1.09-4.01,P=0.03)。

要点

  • 在诊断性神经放射学错误病例中,感知错误占74.8%(190/254),解读错误占25.2%(64/254)。
  • 经验≤5年的神经放射学主治医师发生解读错误的比值比为2.09(95%CI 1.05-4.15,P=0.04)。
  • MR检查较CT检查更易发生解读错误(OR=2.10,95%CI 1.09-4.01,P=0.03)。

核心结论

  • 在诊断性神经放射学错误病例中,解读错误与感知错误受神经放射学医师经验、检查技术和病例数量及判读速度影响,识别这些危险因素可能有助于指导临床神经放射学服务中的错误减少计划。

研究设计与样本

  • 对254例诊断性神经放射学临床错误病例进行分类(感知错误或解读错误),并分析影像技术、判读医师经验、解剖部位、疾病病因、一天中的时间、星期几、每班工作时长、每班判读病例数、每班每小时平均判读病例数及错误发生时的病例顺序。

诊断标准与关键数值

  • 感知错误占74.8%(n=190),解读错误占25.2%(n=64)。
  • 经验≤5年的神经放射学主治医师发生解读错误的OR为2.09(95%CI 1.05-4.15,P=0.04)。
  • MR检查较CT检查发生解读错误的OR为2.10(95%CI 1.09-4.01,P=0.03)。
  • 感染性/炎症性/自身免疫性疾病更常与解读错误相关(P=0.04)。
  • 感知错误与更快的判读速度相关(每小时判读6.01例 vs 5.03例,P=0.004),且发生在班次更晚时段(第24例 vs 第18例,P=0.04)。

临床应用与阅片要点

  • 作者认为,识别这些危险因素可能有助于指导临床神经放射学服务中的错误减少计划。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Diagnostic errors in radiology are classified as perception or interpretation errors. This study determined whether specific conditions differed when perception or interpretation errors occurred during neuroradiology image interpretation.

MATERIALS AND METHODS: In a sample of 254 clinical error cases in diagnostic neuroradiology, we classified errors as perception or interpretation errors, then characterized imaging technique, interpreting radiologist's experience, anatomic location of the abnormality, disease etiology, time of day, and day of the week. Interpretation and perception errors were compared with hours worked per shift, cases read per shift, average cases read per shift hour, and the order of case during the shift when the error occurred.

RESULTS: Perception and interpretation errors were 74.8% (n = 190) and 25.2% (n = 64) of errors, respectively. Logistic regression analyses showed that the odds of an interpretation error were 2 times greater (OR, 2.09; 95% CI, 1.05-4.15; P = .04) for neuroradiology attending physicians with ≤5 years of experience. Interpretation errors were more likely with MR imaging compared with CT (OR, 2.10; 95% CI, 1.09-4.01; P = .03). Infectious/inflammatory/autoimmune diseases were more frequently associated with interpretation errors (P = .04). Perception errors were associated with faster reading rates (6.01 versus 5.03 cases read per hour; P = .004) and occurred later during the shift (24th-versus-18th case; P = .04).

CONCLUSIONS: Among diagnostic neuroradiology error cases, interpretation-versus-perception errors are affected by the neuroradiologist's experience, technique, and the volume and rate of cases read. Recognition of these risk factors may help guide programs for error reduction in clinical neuroradiology services.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Patel SH, Stanton CL, Miller SG, et al. Risk Factors for Perceptual-versus-Interpretative Errors in Diagnostic Neuroradiology. AJNR Am J Neuroradiol. 2019. PMID: 31296527. doi:10.3174/ajnr.A6125

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。