孕期3T磁共振成像的母婴安全性
单中心回顾性病例对照研究纳入2008年1月至2015年3月连续出生的健康新生儿,其中宫内暴露于3T MR者81例,按出生日期1:2随机匹配未暴露对照162例。暴露组与对照组平均出生体重分别为3398 g与3510 g(p=0.06),听力障碍发生率分别为0%(0/81)与1.8%(3/162)(p=0.55),均无显著差异。
要点
- 宫内3T MR暴露与未暴露新生儿的平均出生体重无显著差异(3398 g vs 3510 g,p=0.06)。
- 宫内3T MR暴露与未暴露新生儿的听力障碍发生率无显著差异(0% [0/81] vs 1.8% [3/162],p=0.55)。
- 本研究未显示健康新生儿在任何孕周因各种临床母胎指征接受宫内3T MR暴露后出现听力或胎儿生长方面的不良效应。
核心结论
- 本研究显示,健康新生儿在任何孕周因各种临床母胎指征接受宫内3T MR暴露后,未出现新生儿听力或胎儿生长方面的不良效应。
研究设计与样本
- 单中心回顾性病例对照研究,纳入2008年1月至2015年3月连续出生的健康新生儿,其中宫内暴露于3T MR者81例,按出生日期1:2随机匹配未暴露健康对照162例;采用非配对t检验比较出生体重,Fisher精确检验比较听力障碍。
诊断标准与关键数值
- MR暴露组平均出生体重3398 g,对照组3510 g,两组差异无统计学意义(p=0.06)。
- MR暴露组听力障碍发生率为0%(0/81),对照组为1.8%(3/162),两组差异无统计学意义(p=0.55)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of this study was to evaluate the effects of clinical 3-T MRI during pregnancy on fetal growth and neonatal hearing in neonates at low risk of congenital hearing impairment or of brain or chromosomal abnormalities. MATERIALS AND METHODS. This single-center retrospective case-control study included consecutively born healthy neonates exposed in utero to 3-T MR during MRI for maternal or fetal indications and born between January 2008 and March 2015. Each exposed neonate was randomly matched 1:2 by birth date to healthy control neonates who had not been exposed to MR. Infant birth weights were compared by unpaired t test. Hearing impairment between groups was compared by Fisher exact test. RESULTS. There was no significant difference in mean birth weight between the MR-exposed (3398 g) and control (3510 g) neonates (p = 0.06). There was no significant difference in prevalence of hearing impairment (p = 0.55) between the MR-exposed (0% [0/81]) and control (1.8% [3/162]) groups. CONCLUSION. This study showed no adverse effects with regard to neonatal hearing or fetal growth in healthy neonates who were variably exposed to 3-T MR in utero during MRI for various clinical maternal or fetal indications at any gestational age.
引用
- Chartier AL, Bouvier MJ, McPherson DR, et al. The Safety of Maternal and Fetal MRI at 3 T. AJR Am J Roentgenol. 2019. PMID: 31310182. doi:10.2214/AJR.19.21400
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。