指南与共识介入外周血管技术与安全US

是否应强化美国疾病控制与预防中心关于及时拔除不必要中心静脉导管的建议?超声引导下外周静脉置管以完全依从

Should the CDC's recommendations for promptly removing unnecessary centrally inserted central catheters be enhanced? Ultrasound-guided peripheral venous cannulation to fully comply.
指南 / 共识 · J Vasc Access · 2019-07-21

在重症监护病房实施美国疾病控制与预防中心推荐的多种循证操作以降低导管相关血流感染发生率,但未能完全依从及时拔除中心静脉导管的建议,主要归因于建立外周静脉通路困难。随后一年引入超声引导下外周静脉置管作为补充干预,导管相关血流感染发生率显著降低至预期范围之外,中心静脉导管使用率降低10.7%(p<0.05;58%-47%),导管相关血流感染发生率每千导管日降低11.7(15.9-4.16/1000中心静脉导管日,分别为2015-2016组)。

要点

  • 超声引导下外周静脉置管作为补充干预,可提高对及时拔除不必要中心静脉导管建议的依从性。
  • 中心静脉导管使用率降低10.7%(p<0.05;58%-47%)。
  • 导管相关血流感染发生率每千导管日降低11.7(15.9-4.16/1000中心静脉导管日,分别为2015-2016组)。

核心结论

  • 导管相关血流感染下降幅度高于已发表文献所述,可能表明美国疾病控制与预防中心推荐的五项循证操作联合超声引导下外周静脉置管法,通过影响患者中心静脉导管暴露,能更有效提高对IA类推荐(拔除或避免不必要放置中心静脉导管)的依从性并降低导管相关血流感染。

研究设计与样本

  • 在重症监护病房实施美国疾病控制与预防中心推荐的多种循证操作后,将超声引导下外周静脉置管作为补充干预并在随后一年进行考察;比较2015-2016组中心静脉导管使用率和导管相关血流感染发生率。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: In an effort to reduce catheter-related bloodstream infection's incidence rates in an intensive care unit, several evidence-based procedures recommended by the Centers for Disease Control and Prevention for centrally inserted central catheters were implemented. A failure to fully comply with the recommendation for prompt removal of the centrally inserted central catheters was attributed, mainly to the difficulties and inadequacies raised from establishing peripheral venous access.

METHODS: The ultrasound-guided peripheral venous cannulation method as a supplementary intervention to the Centers for Disease Control and Prevention's recommendations was incorporated and examined during the subsequent year.

RESULTS: A significant reduction on catheter-related bloodstream infection incidence rates out of the expected range was found. Centrally inserted central catheters utilization ratios were reduced by 10.7% (p < 0.05; 58%-47%) and the catheter-related bloodstream infection incidence rate was reduced by 11.7 per thousand device-days (15.9-4.16/1000 centrally inserted central catheters days (2015-2016 group, respectively)).

CONCLUSION: The reduction of catheter-related bloodstream infection was higher than that described in the published literature. This probably shows that the combination of the five evidence-based procedures recommended by the Centers for Disease Control and Prevention together with that of ultrasound-guided peripheral venous cannulation method can increase the compliance with the Category IA recommendation for removal or avoidance of unnecessary placement of centrally inserted central catheters and decrease the catheter-related bloodstream infections in a more effective way, by affecting the patients' centrally inserted central catheter exposure.

来源:J Vasc Access,查看原文。版权归原作者所有。

引用

  1. Iordanou S, Middleton N, Papathanassoglou E, et al. Should the CDC's recommendations for promptly removing unnecessary centrally inserted central catheters be enhanced? Ultrasound-guided peripheral venous cannulation to fully comply. J Vasc Access. 2019. PMID: 31328625. doi:10.1177/1129729819863556

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。